• Call +1.858.633.0165 or Fax +1.858.633.0166 or Contact Us

AGT elisa kit :: Mouse Angiotensinogen (AGT) ELISA Kit

Scan QR to view Datasheet
Catalog # MBS2023277 (SPECIAL PROMOTION: Get FREE Starbucks gift card ($5 for 48-Wells-Kit or $10 for 96-Wells-Kit. Maximum 5 gift cards/product). Gift card(s) will be included with shipment)
Unit / Price
  24-Strip-Wells  /  $260 +1 FREE 8GB USB
  48-Strip-Wells  /  $465 +1 FREE 8GB USB
  96-Strip-Wells  /  $625 +1 FREE 8GB USB
  5x96-Strip-Wells  /  $2,530 +3 FREE 8GB USB
  10x96-Strip-Wells  /  $4,565 +5 FREE 8GB USB
Typical Testing Data/Standard Curve (for reference only)
Product Name

Angiotensinogen (AGT), ELISA Kit

Popular Item
Also Known As

Angiotensinogen (AGT) ELISA Kit

Product Synonym Names
ANHU; SERPINA8; Angiotensin; Renin Substrate; Serpin Peptidase Inhibitor,Clade A,Member 8(Alpha-1 Antiproteinase,Antitrypsin)
Product Gene Name
Research Use Only
For Research Use Only. Not for use in diagnostic procedures.
Request for Current Manual Insert
Sequence Length
485
OMIM
106150
3D Structure
ModBase 3D Structure for P01019
Species Reactivity
Specificity
This assay has high sensitivity and excellent specificity for detection of Angiotensinogen (AGT).
No significant cross-reactivity or interference between Angiotensinogen (AGT) and analogues was observed.
Assay Type
Double-antibody Sandwich
Samples
Serum, Plasma, Tissue homogenates, Cell lysates, Cell culture supernates and Other Biological Fluids
Detection Range
7.8-500ng/mL
Sensitivity
< 2.7ng/mL
Application
Enzyme-linked immunosorbent assay for Antigen Detection.
Intra-assay Precision (Precision within an assay)
3 samples with low, middle and high level Angiotensinogen (AGT) were tested 20 times on one plate, respectively.
Inter-assay Precision (Precision between assays)
3 samples with low, middle and high level Angiotensinogen (AGT) were tested on 3 different plates, 8 replicates in each plate.
CV(%) =
SD/meanX100
Intra-Assay
CV<10%
Inter-Assay
CV<12%
Preparation and Storage
The stability of kit is determined by the loss rate of activity. The loss rate of this kit is less than 5% within the expiration date under appropriate storage condition.
To minimize extra influence on the performance, operation procedures and lab conditions, especially room temperature, air humidity, incubator temperature should be strictly controlled. It is also strongly suggested that the whole assay is performed by the same operator from the beginning to the end.
Product Note
Our ELISA Kit assays are dynamic research tools and sometimes they may be updated and improved. If the format of this assay is important to you then please request the current manual or contact our technical support team with a presales inquiry before placing an order. We will confirm the current details of the assay. We cannot guarantee the sample manual posted online is the most current manual.
Other Notes
Small volumes of AGT elisa kit vial(s) may occasionally become entrapped in the seal of the product vial during shipment and storage. If necessary, briefly centrifuge the vial on a tabletop centrifuge to dislodge any liquid in the container`s cap. Certain products may require to ship with dry ice and additional dry ice fee may apply.
Searchable Terms forAGTpurchase
MBS2023277 is a ready-to-use microwell, strip plate ELISA (enzyme-linked immunosorbent assay) Kit for analyzing the presence of the Angiotensinogen (AGT) ELISA Kit target analytes in biological samples. The concentration gradients of the kit standards or positive controls render a theoretical kit detection range in biological research samples containing AGT. The ELISA analytical biochemical technique of the MBS2023277 kit is based on AGT antibody-AGT antigen interactions (immunosorbency) and an HRP colorimetric detection system to detect AGT antigen targets in samples. The ELISA Kit is designed to detect native, not recombinant, AGT. Appropriate sample types may include undiluted body fluids and/or tissue homogenates, secretions. Quality control assays assessing reproducibility identified the intra-assay CV (%) and inter-assay CV(%).
Related Product Information for
AGT elisa kit
The test principle applied in this kit is Sandwich enzyme immunoassay. The microtiter plate provided in this kit has been pre-coated with an antibody specific to Angiotensinogen (AGT). Standards or samples are then added to the appropriate microtiter plate wells with a biotin-conjugated antibody specific to Angiotensinogen (AGT). Next, Avidin conjugated to Horseradish Peroxidase (HRP) is added to each microplate well and incubated. After TMB substrate solution is added, only those wells that contain Angiotensinogen (AGT), biotin-conjugated antibody and enzyme-conjugated Avidin will exhibit a change in color. The enzyme-substrate reaction is terminated by the addition of sulphuric acid solution and the color change is measured spectrophotometrically at a wavelength of 450nm ± 10nm. The concentration of Angiotensinogen (AGT) in the samples is then determined by comparing the O.D. of the samples to the standard curve.
Product Categories/Family for AGT elisa kit

Typical Testing Data/Standard Curve (for reference only) of AGT elisa kit
AGT elisa kit Typical Testing Data/Standard Curve (for reference only) image
Sample Manual Insert of MBS2023277. Click to request current manual
NCBI/Uniprot data below describe general gene information for AGT. It may not necessarily be applicable to this product.
NCBI GI #
NCBI GeneID
NCBI Accession #
UniProt Primary Accession #
UniProt Secondary Accession #
UniProt Related Accession #
Molecular Weight
53,154 Da
NCBI Official Full Name
angiotensinogen
NCBI Official Synonym Full Names
angiotensinogen (serpin peptidase inhibitor, clade A, member 8)
NCBI Official Symbol
NCBI Official Synonym Symbols
ANHU; SERPINA8
  [Similar Products]
NCBI Protein Information
angiotensinogen
UniProt Protein Name
Angiotensinogen
UniProt Synonym Protein Names
Serpin A8
Protein Family
UniProt Gene Name
UniProt Synonym Gene Names
SERPINA8; Ang I; Ang II; Ang III; Ang IV  [Similar Products]
UniProt Entry Name
ANGT_HUMAN
NCBI Summary for AGT
The protein encoded by this gene, pre-angiotensinogen or angiotensinogen precursor, is expressed in the liver and is cleaved by the enzyme renin in response to lowered blood pressure. The resulting product, angiotensin I, is then cleaved by angiotensin converting enzyme (ACE) to generate the physiologically active enzyme angiotensin II. The protein is involved in maintaining blood pressure and in the pathogenesis of essential hypertension and preeclampsia. Mutations in this gene are associated with susceptibility to essential hypertension, and can cause renal tubular dysgenesis, a severe disorder of renal tubular development. Defects in this gene have also been associated with non-familial structural atrial fibrillation, and inflammatory bowel disease. [provided by RefSeq, Jul 2008]
UniProt Comments for AGT
angiotensin: Essential component of the renin-angiotensin system (RAS), a potent regulator of blood pressure, body fluid and electrolyte homeostasis. In response to lowered blood pressure, the enzyme renin cleaves angiotensinogen to produce angiotensin-1 (angiotensin 1-10). Angiotensin-1 is a substrate of ACE (angiotensin converting enzyme) that removes a dipeptide to yield the physiologically active peptide angiotensin-2 (angiotensin 1- 8). Angiotensin-1 and angiotensin-2 can be further processed to generate angiotensin-3 (angiotensin 2-8), angiotensin-4 (angiotensin 3-8). Angiotensin 1-7 is cleaved from angiotensin-2 by ACE2 or from angiotensin-1 by MME (neprilysin). Angiotensin 1-9 is cleaved from angiotensin-1 by ACE2. Genetic variations in AGT are a cause of susceptibility to essential hypertension (EHT). Essential hypertension is a condition in which blood pressure is consistently higher than normal with no identifiable cause. Defects in AGT are a cause of renal tubular dysgenesis (RTD). RTD is an autosomal recessive severe disorder of renal tubular development characterized by persistent fetal anuria and perinatal death, probably due to pulmonary hypoplasia from early-onset oligohydramnios (the Potter phenotype). Belongs to the serpin family.

Protein type: Secreted; Secreted, signal peptide

Chromosomal Location of Human Ortholog: 1q42.2

Cellular Component: extracellular space; cytoplasm; extracellular region

Molecular Function: serine-type endopeptidase inhibitor activity; protein binding; growth factor activity; sodium channel regulator activity; hormone activity; superoxide-generating NADPH oxidase activator activity; type 2 angiotensin receptor binding; type 1 angiotensin receptor binding

Biological Process: renal system process; extracellular matrix organization and biogenesis; positive regulation of nitric oxide biosynthetic process; establishment of blood-nerve barrier; negative regulation of nerve growth factor receptor signaling pathway; positive regulation of transcription, DNA-dependent; stress-activated MAPK cascade; positive regulation of multicellular organism growth; female pregnancy; positive regulation of vasodilation; activation of NF-kappaB transcription factor; ovarian follicle rupture; positive regulation of fibroblast proliferation; cell-cell signaling; positive regulation of superoxide release; negative regulation of neuron apoptosis; kidney development; positive regulation of NAD(P)H oxidase activity; positive regulation of cytokine production; angiotensin mediated regulation of renal output; response to muscle activity involved in regulation of muscle adaptation; regulation of calcium ion transport; regulation of norepinephrine secretion; positive regulation of phosphoinositide 3-kinase cascade; negative regulation of tissue remodeling; positive regulation of peptidyl-tyrosine phosphorylation; phospholipase C activation; angiotensin mediated vasoconstriction involved in regulation of systemic arterial blood pressure; regulation of transmission of nerve impulse; regulation of vasoconstriction; G-protein signaling, coupled to IP3 second messenger (phospholipase C activating); smooth muscle cell differentiation; cytokine secretion; nitric oxide mediated signal transduction; regulation of long-term neuronal synaptic plasticity; peristalsis; cell-matrix adhesion; renin-angiotensin regulation of aldosterone production; positive regulation of cellular protein metabolic process; smooth muscle cell proliferation; cellular lipid metabolic process; angiotensin maturation; excretion; vasodilation; response to salt stress; negative regulation of cell proliferation; fibroblast proliferation; positive regulation of MAPKKK cascade; renin-angiotensin regulation of blood vessel size; positive regulation of epidermal growth factor receptor signaling pathway; regulation of blood pressure; renin-angiotensin regulation of blood volume; regulation of cell growth; angiotensin mediated drinking behavior; artery smooth muscle contraction; aging; blood vessel development; positive regulation of fatty acid biosynthetic process; cellular sodium ion homeostasis; renal response to blood flow during renin-angiotensin regulation of systemic arterial blood pressure; activation of NF-kappaB-inducing kinase; positive regulation of peptidyl-serine phosphorylation; positive regulation of organ growth; regulation of cell proliferation; G-protein coupled receptor protein signaling pathway; negative regulation of angiogenesis; cellular protein metabolic process; ureteric bud branching; G-protein signaling, coupled to cGMP nucleotide second messenger; blood vessel remodeling; negative regulation of cell growth; response to cold; astrocyte activation; positive regulation of inflammatory response

Disease: Renal Tubular Dysgenesis; Hypertension, Essential
Precautions
All of MyBioSource's Products are for scientific laboratory research purposes and are not for diagnostic, therapeutics, prophylactic or in vivo use. Through your purchase, you expressly represent and warrant to MyBioSource that you will properly test and use any Products purchased from MyBioSource in accordance with industry standards. MyBioSource and its authorized distributors reserve the right to refuse to process any order where we reasonably believe that the intended use will fall outside of our acceptable guidelines.
Disclaimer
While every efforts were made to ensure the accuracy of the information provided in this datasheet, MyBioSource will not be liable for any omissions or errors contained herein. MyBioSource reserves the right to make changes to this datasheet at any time without prior notice.

It is the responsibility of the customer to report product performance issues to MyBioSource within 30 days of receipt of the product. Please visit our Terms & Conditions page for more information.
Request a Quote

Please fill out the form below and our representative will get back to you shortly.

MBS000000
Contact Us

Please fill out the form below and our representative will get back to you shortly.

MBS000000