C-telopeptide of type II collagen, CTX-II elisa kit
Product Name

C-telopeptide of type II collagen, CTX-II, ELISA Kit

Full Product Name

Bovine C-telopeptide of type II collagen, CTX-II ELISA Kit

Product Synonym Names
Bovine C-telopeptide of type II collagen; CTX-II ELISA Kit; C-telopeptide of type II collagen; CTX-II
Research Use Only
For Research Use Only. Not for use in diagnostic procedures.
Request for Current Manual Insert
Species Reactivity
Specificity
This assay has high sensitivity and excellent specificity for detection of horse CTX-II. No significant cross-reactivity or interference between horse CTX-II and analogues was observed.
Samples
Serum, plasma, tissue homogenates.
Assay Type
Sandwich (Quantitative)
Detection Range
1.56 ng/ml -100 ng/ml.
Sensitivity
0.39 ng/ml.
Intra-assay Precision
Intra-assay Precision (Precision within an assay): CV%<8%. Three samples of known concentration were tested twenty times on one plate to assess.
Inter-assay Precision
Inter-assay Precision (Precision between assays): CV%<10%. Three samples of known concentration were tested in twenty assays to assess.
Preparation and Storage
Unopened test kits should be stored at 2 to 8 degree C upon receipt. Please refer to pdf manual for further storage instructions.
ISO Certification
Manufactured in an ISO 13485:2003 and EN ISO 13485:2012 Certified Laboratory.
Product Note
Our ELISA Kit assays are dynamic research tools and sometimes they may be updated and improved. If the format of this assay is important to you then please request the current manual or contact our technical support team with a presales inquiry before placing an order. We will confirm the current details of the assay. We cannot guarantee the sample manual posted online is the most current manual.
Other Notes
Small volumes of C-telopeptide of type II collagen, CTX-II elisa kit vial(s) may occasionally become entrapped in the seal of the product vial during shipment and storage. If necessary, briefly centrifuge the vial on a tabletop centrifuge to dislodge any liquid in the container`s cap. Certain products may require to ship with dry ice and additional dry ice fee may apply.
Searchable Terms for C-telopeptide of type II collagen, CTX-IIpurchase
MBS707021 is a ready-to-use microwell, strip plate ELISA (enzyme-linked immunosorbent assay) Kit for analyzing the presence of the C-telopeptide of type II collagen, CTX-II, ELISA Kit target analytes in biological samples. The concentration gradients of the kit standards or positive controls render a theoretical kit detection range in biological research samples containing C-telopeptide of type II collagen, CTX-II. The ELISA analytical biochemical technique of the MBS707021 kit is based on C-telopeptide of type II collagen, CTX-II antibody-C-telopeptide of type II collagen, CTX-II antigen interactions (immunosorbency) and an HRP colorimetric detection system to detect C-telopeptide of type II collagen, CTX-II antigen targets in samples. The ELISA Kit is designed to detect native, not recombinant, C-telopeptide of type II collagen, CTX-II. Appropriate sample types may include undiluted body fluids and/or tissue homogenates, secretions. Quality control assays assessing reproducibility identified the intra-assay CV (%) and inter-assay CV(%).
Principle of the Assay: This assay employs the quantitative sandwich enzyme immunoassay technique. Antibody specific for CTX-II has been pre-coated onto a microplate. Standards and samples are pipetted into the wells and any CTX-II present is bound by the immobilized antibody. After removing any unbound substances, a biotin-conjugated antibody specific for CTX-II is added to the wells. After washing, avidin conjugated Horseradish Peroxidase (HRP) is added to the wells. Following a wash to remove any unbound avidin-enzyme reagent, a substrate solution is added to the wells and color develops in proportion to the amount of CTX-II bound in the initial step. The color development is stopped and the intensity of the color is measured.
Sample Manual Insert of MBS707021. Click to request current manual
Precautions
All of MyBioSource's Products are for scientific laboratory research purposes and are not for diagnostic, therapeutics, prophylactic or in vivo use. Through your purchase, you expressly represent and warrant to MyBioSource that you will properly test and use any Products purchased from MyBioSource in accordance with industry standards. MyBioSource and its authorized distributors reserve the right to refuse to process any order where we reasonably believe that the intended use will fall outside of our acceptable guidelines.
Disclaimer
While every efforts were made to ensure the accuracy of the information provided in this datasheet, MyBioSource will not be liable for any omissions or errors contained herein. MyBioSource reserves the right to make changes to this datasheet at any time without prior notice.

It is the responsibility of the customer to report product performance issues to MyBioSource within 30 days of receipt of the product. Please visit our Terms & Conditions page for more information.
Request a Quote

Please fill out the form below and our representative will get back to you shortly.

MBS000000
Contact Us

Please fill out the form below and our representative will get back to you shortly.

MBS000000