• Call +1.858.633.0165 or Fax +1.858.633.0166 or Contact Us

GLP1R elisa kit :: Mouse glucagon-like peptide 1 receptor ELISA Kit

Scan QR to view Datasheet
Catalog # MBS930494
Unit / Price
  24-Strip-Wells (LIMIT 1)  /  $240 +1 FREE 8GB USB
  48-Strip-Wells  /  $495 +1 FREE 8GB USB
  96-Strip-Wells  /  $710 +1 FREE 8GB USB
  5x96-Strip-Wells  /  $2,705 +3 FREE 8GB USB
  10x96-Strip-Wells  /  $5,145 +6 FREE 8GB USB
Typical Testing Data/Standard Curve (for reference only)
Product Name

glucagon-like peptide 1 receptor (GLP1R), ELISA Kit

Also Known As

Mouse Glucagon-like peptide 1 receptor, GLP1R ELISA Kit

Product Synonym Names
Mouse Glucagon-like peptide 1 receptor (GLP1R) ELISA kit; MGC138331; ; glucagon-like peptide 1 receptor
Product Gene Name
Research Use Only
For Research Use Only. Not for use in diagnostic procedures.
Request for Current Manual Insert
MBS930494 Testing Data
Sequence Length
463
3D Structure
ModBase 3D Structure for O35659
Species Reactivity
Specificity
This assay has high sensitivity and excellent specificity for detection of mouse GLP1R. No significant cross-reactivity or interference between mouse GLP1R and analogues was observed.
Samples
Serum, plasma, tissue homogenates, Cell lysates
Assay Type
Sandwich
Detection Range
23.44 pg/ml-1500 pg/ml.
Sensitivity
The minimum detectable dose of mouse GLP1R is typically less than 5.86 pg/ml. The sensitivity of this assay, or Lower Limit of Detection (LLD) was defined as the lowest protein concentration that could be differentiated from zero. It was determined the mean O.D value of 20 replicates of the zero standard added by their three standard deviations.
Intra-assay Precision
Intra-assay Precision (Precision within an assay): CV%<8%. Three samples of known concentration were tested twenty times on one plate to assess.
Inter-assay Precision
Inter-assay Precision (Precision between assays): CV%<10%. Three samples of known concentration were tested in twenty assays to assess.
Preparation and Storage
Unopened test kits should be stored at 2 to 8 degree C upon receipt. Please refer to pdf manual for further storage instructions.
ISO Certification
Manufactured in an ISO 9001:2008 Certified Laboratory.
Product Note
Our ELISA Kit assays are dynamic research tools and sometimes they may be updated and improved. If the format of this assay is important to you then please request the current manual or contact our technical support team with a presales inquiry before placing an order. We will confirm the current details of the assay. We cannot guarantee the sample manual posted online is the most current manual.
Other Notes
Small volumes of GLP1R elisa kit vial(s) may occasionally become entrapped in the seal of the product vial during shipment and storage. If necessary, briefly centrifuge the vial on a tabletop centrifuge to dislodge any liquid in the container`s cap. Certain products may require to ship with dry ice and additional dry ice fee may apply.
Searchable Terms forGLP1Rpurchase
MBS930494 is a ready-to-use microwell, strip plate ELISA (enzyme-linked immunosorbent assay) Kit for analyzing the presence of the glucagon-like peptide 1 receptor (GLP1R) ELISA Kit target analytes in biological samples. The concentration gradients of the kit standards or positive controls render a theoretical kit detection range in biological research samples containing GLP1R. The ELISA analytical biochemical technique of the MBS930494 kit is based on GLP1R antibody-GLP1R antigen interactions (immunosorbency) and an HRP colorimetric detection system to detect GLP1R antigen targets in samples. The ELISA Kit is designed to detect native, not recombinant, GLP1R. Appropriate sample types may include undiluted body fluids and/or tissue homogenates, secretions. Quality control assays assessing reproducibility identified the intra-assay CV (%) and inter-assay CV(%).
Related Product Information for
GLP1R elisa kit
Principle of the assay: This assay employs the quantitative sandwich enzyme immunoassay technique. Antibody specific for GLP1R has been pre-coated onto a microplate. Standards and samples are pipetted into the wells and any GLP1R present is bound by the immobilized antibody. After removing any unbound substances, a biotin-conjugated antibody specific for GLP1R is added to the wells. After washing, avidin conjugated Horseradish Peroxidase (HRP) is added to the wells. Following a wash to remove any unbound avidin-enzyme reagent, a substrate solution is added to the wells and color develops in proportion to the amount of GLP1R bound in the initial step. The color development is stopped and the intensity of the color is measured.

Typical Testing Data/Standard Curve (for reference only) of GLP1R elisa kit
GLP1R elisa kit Typical Testing Data/Standard Curve (for reference only) image
Sample Manual Insert of MBS930494. Click to request current manual
NCBI/Uniprot data below describe general gene information for GLP1R. It may not necessarily be applicable to this product.
NCBI GI #
NCBI GeneID
NCBI Accession #
NCBI GenBank Nucleotide #
UniProt Primary Accession #
UniProt Secondary Accession #
UniProt Related Accession #
Molecular Weight
53,028 Da
NCBI Official Full Name
glucagon-like peptide 1 receptor
NCBI Official Synonym Full Names
glucagon-like peptide 1 receptor
NCBI Official Symbol
Glp1r  [Similar Products]
NCBI Official Synonym Symbols
GLP-1R; GLP1Rc
  [Similar Products]
NCBI Protein Information
glucagon-like peptide 1 receptor; GLP-1-R; GLP-1 receptor
UniProt Protein Name
Glucagon-like peptide 1 receptor
UniProt Gene Name
Glp1r  [Similar Products]
UniProt Synonym Gene Names
GLP-1 receptor; GLP-1-R; GLP-1R  [Similar Products]
UniProt Entry Name
GLP1R_MOUSE
UniProt Comments for GLP1R
GLP1R: This is a receptor for glucagon-like peptide 1. The activity of this receptor is mediated by G proteins which activate adenylyl cyclase. Belongs to the G-protein coupled receptor 2 family.

Protein type: Membrane protein, integral; GPCR, family 2; Receptor, GPCR; Membrane protein, multi-pass

Cellular Component: membrane; integral to plasma membrane; plasma membrane; integral to membrane; intracellular; cytosol

Molecular Function: G-protein coupled receptor activity; signal transducer activity; transmembrane receptor activity; peptide receptor activity; peptide hormone binding; peptide receptor activity, G-protein coupled; glucagon receptor activity; receptor activity

Biological Process: hormone secretion; positive regulation of insulin secretion; regulation of calcium ion transport; signal transduction; G-protein signaling, adenylate cyclase activating pathway; memory; regulation of heart contraction; G-protein coupled receptor protein signaling pathway; cAMP-mediated signaling; elevation of cytosolic calcium ion concentration; cell surface receptor linked signal transduction; learning and/or memory; insulin secretion; neuropeptide signaling pathway; release of sequestered calcium ion into cytosol; positive regulation of cell proliferation; response to glucose stimulus; response to stress; positive regulation of transcription from RNA polymerase II promoter; feeding behavior; negative regulation of neuron apoptosis; positive regulation of cell differentiation; positive regulation of heart contraction; associative learning; positive regulation of blood pressure; negative regulation of apoptosis
Research Articles on GLP1R
Precautions
All of MyBioSource's Products are for scientific laboratory research purposes and are not for diagnostic, therapeutics, prophylactic or in vivo use. Through your purchase, you expressly represent and warrant to MyBioSource that you will properly test and use any Products purchased from MyBioSource in accordance with industry standards. MyBioSource and its authorized distributors reserve the right to refuse to process any order where we reasonably believe that the intended use will fall outside of our acceptable guidelines.
Disclaimer
While every efforts were made to ensure the accuracy of the information provided in this datasheet, MyBioSource will not be liable for any omissions or errors contained herein. MyBioSource reserves the right to make changes to this datasheet at any time without prior notice.

It is the responsibility of the customer to report product performance issues to MyBioSource within 30 days of receipt of the product. Please visit our Terms & Conditions page for more information.
Organs/Tissues associated with GLP1R elisa kit
 Organ/Tissue Name  Pubmed Publications
 Mixed Antibodies  >1 publications with GLP1R and Mixed
Request a Quote

Please fill out the form below and our representative will get back to you shortly.

MBS000000
Contact Us

Please fill out the form below and our representative will get back to you shortly.

MBS000000