• Call +1.858.633.0165 or Fax +1.858.633.0166 or Contact Us

Human Pancreatic carcinoma markers-CA242 ELISA Kit

Scan QR to view Datasheet
Catalog # MBS701782
Unit / Price
  24-Strip-Wells (LIMIT 1)  /  $240 +1 FREE 8GB USB
  48-Strip-Wells  /  $550 +1 FREE 8GB USB
  96-Strip-Wells  /  $795 +1 FREE 8GB USB
  5x96-Strip-Wells  /  $2,890 +3 FREE 8GB USB
  10x96-Strip-Wells  /  $5,465 +6 FREE 8GB USB
Typical Testing Data/Standard Curve (for reference only)
Product Name

Pancreatic carcinoma markers-CA242, ELISA Kit

Also Known As

Human Pancreatic carcinoma markers-CA242 ELISA Kit

Product Synonym Names
Human Pancreatic carcinoma markers-CA242 ELISA Kit; Pancreatic carcinoma markers-CA242
Research Use Only
For Research Use Only. Not for use in diagnostic procedures.
Request for Current Manual Insert
MBS701782 Testing Data
Species Reactivity
Specificity
This assay has high sensitivity and excellent specificity for detection of human CA242. No significant cross-reactivity or interference between human CA242 and analogues was observed.
Samples
Serum, plasma and tissue homogenate
Assay Type
Sandwich
Detection Range
3.33 U/ml-50 U/ml.
Sensitivity
The minimum detectable dose of human CA242 is typically less than 0.83 U/ml. The sensitivity of this assay, or Lower Limit of Detection (LLD) was defined as the lowest human CA242 concentration that could be differentiated from zero. It was determined the mean O.D value of 20 replicates of the zero standard added by their three standard deviations.
Intra-assay Precision
Intra-assay Precision (Precision within an assay): CV%<15%. Three samples of known concentration were tested twenty times on one plate to assess.
Inter-assay Precision
Inter-assay Precision (Precision between assays): CV%<20%. Three samples of known concentration were tested in twenty assays to assess.
Preparation and Storage
Unopened test kits should be stored at 2 to 8 degree C upon receipt. Please refer to pdf manual for further storage instructions.
ISO Certification
Manufactured in an ISO 9001:2008 Certified Laboratory.
Product Note
Our ELISA Kit assays are dynamic research tools and sometimes they may be updated and improved. If the format of this assay is important to you then please request the current manual or contact our technical support team with a presales inquiry before placing an order. We will confirm the current details of the assay. We cannot guarantee the sample manual posted online is the most current manual.
Other Notes
Small volumes of Pancreatic carcinoma markers-CA242 elisa kit vial(s) may occasionally become entrapped in the seal of the product vial during shipment and storage. If necessary, briefly centrifuge the vial on a tabletop centrifuge to dislodge any liquid in the container`s cap. Certain products may require to ship with dry ice and additional dry ice fee may apply.
Searchable Terms forPancreatic carcinoma markers-CA242purchase
MBS701782 is a ready-to-use microwell, strip plate ELISA (enzyme-linked immunosorbent assay) Kit for analyzing the presence of the Pancreatic carcinoma markers-CA242, ELISA Kit target analytes in biological samples. The concentration gradients of the kit standards or positive controls render a theoretical kit detection range in biological research samples containing Pancreatic carcinoma markers-CA242. The ELISA analytical biochemical technique of the MBS701782 kit is based on Pancreatic carcinoma markers-CA242 antibody-Pancreatic carcinoma markers-CA242 antigen interactions (immunosorbency) and an HRP colorimetric detection system to detect Pancreatic carcinoma markers-CA242 antigen targets in samples. The ELISA Kit is designed to detect native, not recombinant, Pancreatic carcinoma markers-CA242. Appropriate sample types may include undiluted body fluids and/or tissue homogenates, secretions. Quality control assays assessing reproducibility identified the intra-assay CV (%) and inter-assay CV(%).
Related Product Information for
Pancreatic carcinoma markers-CA242 elisa kit
Principle of the assay: This assay employs the quantitative sandwich enzyme immunoassay technique. The microtiter plate provided in this kit has been pre-coated with antibody specific for CA242. Standards and samples are pipetted into the wells with a Horseradish Peroxidase (HRP) conjugated antibody specific for CA242 and incubated. Following a wash to remove any unbound reagent, a substrate solution is added to the wells and color develops in proportion to the amount of CA242 bound in the initial step. The color development is stopped and the intensity of the color is measured.

Typical Testing Data/Standard Curve (for reference only) of Pancreatic carcinoma markers-CA242 elisa kit
Pancreatic carcinoma markers-CA242 elisa kit Typical Testing Data/Standard Curve (for reference only) image
Sample Manual Insert of MBS701782. Click to request current manual
Precautions
All of MyBioSource's Products are for scientific laboratory research purposes and are not for diagnostic, therapeutics, prophylactic or in vivo use. Through your purchase, you expressly represent and warrant to MyBioSource that you will properly test and use any Products purchased from MyBioSource in accordance with industry standards. MyBioSource and its authorized distributors reserve the right to refuse to process any order where we reasonably believe that the intended use will fall outside of our acceptable guidelines.
Disclaimer
While every efforts were made to ensure the accuracy of the information provided in this datasheet, MyBioSource will not be liable for any omissions or errors contained herein. MyBioSource reserves the right to make changes to this datasheet at any time without prior notice.

It is the responsibility of the customer to report product performance issues to MyBioSource within 30 days of receipt of the product. Please visit our Terms & Conditions page for more information.
Request a Quote

Please fill out the form below and our representative will get back to you shortly.

MBS000000
Contact Us

Please fill out the form below and our representative will get back to you shortly.

MBS000000