Product Name
|
|
cardiac isoform of Troponin T, cTnT, ELISA Kit ★Popular Item★
|
Also Known As
|
|
Canine cardiac isoform of Troponin T, cTnT ELISA Kit
|
Product Synonym Names
|
|
Canine cardiac isoform of Troponin T; cTnT ELISA Kit; Troponin isoform of Troponin T; cTnT
|
Product Gene Name
|
|
|
[Similar Products]
|
Research Use Only
|
|
For Research Use Only. Not for use in diagnostic procedures.
|
TOP
|
Sample Manual Insert
|
|
|
Request for Current Manual Insert
|
|
|
MBS705349 Testing Data
|
|
|
|
Species Reactivity
|
|
Dog
|
|
Specificity
|
|
This assay has high sensitivity and excellent specificity for detection of canine cTnT. No significant cross-reactivity or interference between canine cTnT and analogues was observed.
|
|
Samples
|
|
Serum, plasma, tissue homogenates
|
Assay Type
|
|
Sandwich
|
Detection Range
|
|
15.6 pg/ml -1000 pg/ml.
|
Sensitivity
|
|
The minimum detectable dose of canine cTnT is typically less than 3.9 pg/ml. The sensitivity of this assay, or Lower Limit of Detection (LLD) was defined as the lowest protein concentration that could be differentiated from zero. It was determined the mean O.D value of 20 replicates of the zero standard added by their three standard deviations.
|
Intra-assay Precision
|
|
Intra-assay Precision (Precision within an assay): CV%<8%. Three samples of known concentration were tested twenty times on one plate to assess.
|
Inter-assay Precision
|
|
Inter-assay Precision (Precision between assays): CV%<10%. Three samples of known concentration were tested in twenty assays to assess.
|
|
Preparation and Storage
|
|
Unopened test kits should be stored at 2 to 8 degree C upon receipt. Please refer to pdf manual for further storage instructions.
|
ISO Certification
|
|
Manufactured in an ISO 9001:2008 Certified Laboratory.
|
Product Note
|
|
Our ELISA Kit assays are dynamic research tools and sometimes they may be updated and improved. If the format of this assay is important to you then please request the current manual or contact our technical support team with a presales inquiry before placing an order. We will confirm the current details of the assay. We cannot guarantee the sample manual posted online is the most current manual.
|
Other Notes
|
|
Small volumes of cTnT elisa kit vial(s) may occasionally become entrapped in the seal of the product vial during shipment and storage. If necessary, briefly centrifuge the vial on a tabletop centrifuge to dislodge any liquid in the container`s cap. Certain products may require to ship with dry ice and additional dry ice fee may apply.
|
Searchable Terms for cTnT purchase
|
|
MBS705349 is a ready-to-use microwell, strip plate Sandwich ELISA (enzyme-linked immunosorbent assay) Kit for analyzing the presence of the cardiac isoform of Troponin T, cTnT, ELISA Kit target analytes in biological samples. The concentration gradients of the kit standards or positive controls render a theoretical kit detection range of 15.6 pg/ml -1000 pg/ml in biological research samples containing cTnT, with an estimated sensitivity of The minimum detectable dose of canine cTnT is typically less than 3.9 pg/ml. The sensitivity of this assay, or Lower Limit of Detection (LLD) was defined as the lowest protein concentration that could be differentiated from zero. It was determined the mean O.D value of 20 replicates of the zero standard added by their three standard deviations. The ELISA analytical biochemical technique of the MBS705349 kit is based on cTnT antibody-cTnT antigen interactions (immunosorbency) and an HRP colorimetric detection system to detect cTnT antigen targets in samples. The ELISA Kit is designed to detect native, not recombinant, cTnT. Appropriate sample types may include undiluted body fluids and/or tissue homogenates, secretions such as Serum, plasma, tissue homogenates. Quality control assays assessing reproducibility identified the intra-assay CV (%) and inter-assay CV(%).
|
TOP
|
|
Related Product Information for cTnT elisa kit
|
|
Principle of the assay: This assay employs the quantitative sandwich enzyme immunoassay technique. Antibody specific for cTnT has been pre-coated onto a microplate. Standards and samples are pipetted into the wells and any cTnT present is bound by the immobilized antibody. After removing any unbound substances, a biotin-conjugated antibody specific for cTnT is added to the wells. After washing, avidin conjugated Horseradish Peroxidase (HRP) is added to the wells. Following a wash to remove any unbound avidin-enzyme reagent, a substrate solution is added to the wells and color develops in proportion to the amount of cTnT bound in the initial step. The color development is stopped and the intensity of the color is measured.
|
|
|
Typical Testing Data/Standard Curve (for reference only) of cTnT elisa kit
|
|
|
TOP
|
|
Sample Manual Insert of MBS705349. Click to request current manual
|
|
TOP
|
Precautions
|
|
All of MyBioSource's Products are for scientific laboratory research purposes and are not for diagnostic, therapeutics, prophylactic or in vivo use. Through your purchase, you expressly represent and warrant to MyBioSource that you will properly test and use any Products purchased from MyBioSource in accordance with industry standards. MyBioSource and its authorized distributors reserve the right to refuse to process any order where we reasonably believe that the intended use will fall outside of our acceptable guidelines.
|
Disclaimer
|
|
While every efforts were made to ensure the accuracy of the information provided in this datasheet, MyBioSource will not be liable for any omissions or errors contained herein. MyBioSource reserves the right to make changes to this datasheet at any time without prior notice.
It is the responsibility of the customer to report product performance issues to MyBioSource within 30 days of receipt of the product. Please visit our Terms & Conditions page for more information.
|
TOP
|