View our list of available Coronavirus (COVID-19, SARS-CoV-2, 2019-nCOV) antibodies, recombinant proteins, ELISA Kits... Options Full Datasheet Printer Friendly Datasheet Prepare for Printing Full Datasheet Printer Friendly Datasheet Prepare for Printing Have Questions? Ask Us! Request A Quote Today! Add To Compare List MIS/AMH elisa kit :: GuineaPig Mullerian Inhibiting Substance/Anti-Mullerian hormone ELISA Kit Catalog # MBS733702 Unit / Price Please Inquire Product Name Product Info Accession #s Product Desc Diseases/Tissues/Pathways Applications References Product Name Mullerian Inhibiting Substance/Anti-Mullerian hormone (MIS/AMH), ELISA Kit Full Product Name Guinea Pig Mullerian Inhibiting Substance/Anti-Mullerian hormone ELISA Kit Product Synonym Names Guinea Pig Mullerian Inhibiting Substance/Anti-Mullerian hormone ELISA Kit; Mullerian Inhibiting Substance/Anti-Mullerian hormone; Mullerian Inhibiting Substance/Anti-Mullerian hormone (Guinea Pig) Product Gene Name MIS/AMH elisa kit[Similar Products] Research Use Only For Research Use Only. Not for use in diagnostic procedures. TOP Sample Manual Insert Download Sample PDF Manual View Sample PDF Manual Species Reactivity GuineaPig Samples Cell culture fluid & body fluid & tissue homogenate Serum or blood plasma Preparation and Storage Store all reagents at 2-8 degree C Sample Preparation We suggest pre-experimenting with neat (undiluted) samples, 1:2 or 1:4 dilutions. Please avoid diluting your samples more than 1:10 as it would exceed the dilution limit set for this kit. If the expected concentration of the target is beyond the detection range of the kit, please contact our technical support team ISO Certification Manufactured in an ISO 13485:2016 Certified Laboratory. Product Note Select online data sheet information is drawn from bioinformatics databases, occasionally resulting in ambiguous or non-relevant product information. It is the responsibility of the customer to review, verify, and evaluate the information to make sure it matches their requirements before purchasing the kit. Our ELISA Kit assays are dynamic research tools and sometimes they may be updated and improved. If the format of this assay is important to you then please request the current manual or contact our technical support team with a presales inquiry before placing an order. We will confirm the current details of the assay. We cannot guarantee the sample manual posted online is the most current manual, it is intended to serve as an example only. Please refer to the instructions For Use provided with the assay kit for precise details. Other Notes Small volumes of MIS/AMH elisa kit vial(s) may occasionally become entrapped in the seal of the product vial during shipment and storage. If necessary, briefly centrifuge the vial on a tabletop centrifuge to dislodge any liquid in the container`s cap. Certain products may require to ship with dry ice and additional dry ice fee may apply. Searchable Terms for MIS/AMH purchase MBS733702 is a ready-to-use microwell, strip-or-full plate ELISA (enzyme-linked immunosorbent assay) Kit for analyzing the presence of the Mullerian Inhibiting Substance/Anti-Mullerian hormone (MIS/AMH) ELISA Kit target analytes in biological samples. The concentration gradients of the kit standards or positive controls render a theoretical kit detection range in biological research samples containing MIS/AMH. The ELISA analytical biochemical technique of the MBS733702 kit is based on MIS/AMH antibody-MIS/AMH antigen interactions (immunosorbency) and an HRP colorimetric detection system to detect MIS/AMH antigen targets in samples. The ELISA Kit is designed to detect native, not recombinant, MIS/AMH. Appropriate sample types may include undiluted body fluids and/or tissue homogenates, secretions. Quality control assays assessing reproducibility identified the intra-assay CV (%) and inter-assay CV(%). TOP Related Product Information for MIS/AMH elisa kit For Samples: Cell culture fluid & body fluid & tissue homogenate Serum or blood plasmaIntended Uses: This MIS/AMH ELISA kit is intended for laboratory research use only. The stop solution changes the color from blue to yellow and the intensity of the color is measured at 450 nm using a spectrophotometer. In order to measure the concentration of MIS/AMH in the sample, this MIS/AMH ELISA Kit includes a set of calibration standards. The calibration standards are assayed at the same time as the samples and allow the operator to produce a standard curve of Optical Density versus MIS/AMH concentration. The concentration of in the samples is then determined by comparing the O.D. of the samples to the standard curve.Principle of the Assay: The coated well immunoenzymatic assay for the quantitative measurement of MIS/AMH utilizes a multiclonal anti-MIS/AMH antibody and an MIS/AMH-HRP conjugate. The assay sample and buffer are incubated together with MIS/AMH-HRP conjugate in pre-coated plate for one hour. After the incubation period, the wells are decanted and washed five times. The wells are then incubated with a substrate for HRP enzyme. The product of the enzyme-substrate reaction forms a blue colored complex. Finally, a stop solution is added to stop the reaction, which will then turn the solution yellow. The intensity of color is measured spectrophotometrically at 450nm in a microplate reader. The intensity of the color is inversely proportional to the MIS/AMH concentration since MIS/AMH from samples and MIS/AMH-HRP conjugate compete for the anti-MIS/AMH antibody binding site. Since the number of sites is limited, as more sites are occupied by MIS/AMH from the sample, fewer sites are left to bind MIS/AMH-HRP conjugate. Standards of known MIS/AMH concentrations are run concurrently with the samples being assayed and a standard curve is plotted relating the intensity of the color (Optical Density) to the concentration of MIS/AMH. The MIS/AMH concentration in each sample is interpolated from this standard curve. Product Categories/Family for MIS/AMH elisa kit Guinea Pig ELISA Kit Typical Testing Data/Standard Curve (for reference only) of MIS/AMH elisa kit TOP Sample Manual Insert of MBS733702. Precautions All of MyBioSource's Products are for scientific laboratory research purposes and are not for diagnostic, therapeutics, prophylactic or in vivo use. Through your purchase, you expressly represent and warrant to MyBioSource that you will properly test and use any Products purchased from MyBioSource in accordance with industry standards. MyBioSource and its authorized distributors reserve the right to refuse to process any order where we reasonably believe that the intended use will fall outside of our acceptable guidelines. Disclaimer While every efforts were made to ensure the accuracy of the information provided in this datasheet, MyBioSource will not be liable for any omissions or errors contained herein. MyBioSource reserves the right to make changes to this datasheet at any time without prior notice.It is the responsibility of the customer to report product performance issues to MyBioSource within 30 days of receipt of the product. Please visit our Terms & Conditions page for more information. TOP