Antibody Protein ELISA Kit from MyBioSource header Telephone 1.858.633.0165          
1.855.MyBioSource
Fax 1.858.633.0166    Email sales@mybiosource.com 
tel/fax
menu1 Home Products Ordering Company Help menu7
bottom
   MyBioSource rightarrow ELISA Kit rightarrow AngII rightarrow Mouse AngII  rightarrow LOG IN  rightarrow MY ACCOUNT  rightarrow CART CONTENTS  rightarrow CHECKOUT 
horiz bar
MyBioSource Menu separator
separator
ELISA Kit ELISA Kit
CLIA Kit CLIA Kit
PCR Kit PCR Kit
Monoclonal Antibody Monoclonal Antibody
Polyclonal Antibody Polyclonal Antibody
Secondary Antibody Secondary Antibody
Antigen Antigen
Biochemical Biochemical
cDNA Clone cDNA Clone
siRNA siRNA
Peptide Peptide
Recombinant/Purified Protein Rec./Purified Protein

Custom ELISA Kit Custom ELISA Kit
Custom Protein Custom Protein
Custom Antibody Custom Antibody
Antibody Matched Pairs Antibody Matched Pairs
Antibody & Corresponding Blocking Peptide Pairs Antibody Peptide Pairs
Phospho-Specific Antibodies Phospho Antibodies
Products by Disease Products by Disease
Products by Pathway Products by Pathway
Products by Tissue Products by Tissue

arrow Advanced Search
arrow Submit Technical Q&A
arrow International Distributors
arrow Contact Us
separator
Our Best Sellers moreseparator
separator
 • Surfactant Associated Protein D (SPD) ELISA Kit
 • TTR - Transthyretin Antibody
 • Epinephrine (EPI) ELISA Kit
 • CD42a,b,c,d Complex Antibody
 • LIPC ELISA Kit
 • STC2 cDNA Clone
 • Alpha-2A adrenergic receptor (ADRA2A) Recombinant Protein
 • Complement Component 9 (C9) Recombinant Protein
 • Acid phosphatase 1 (ACP1) Recombinant Protein
 • GlyCAM1 ELISA Kit
 • Bilirubin (Bb) Antibody
 • Anti-centriole and centrosome antibody (ACA) ELISA Kit
 • 30S ribosomal protein S11 (rpsK) Recombinant Protein
 • MYST histone acetyltransferase (monocytic leukemia) 4 (MYST4... ELISA Kit
 downarrow more ...
separator
separator
DatasheetFull DatasheetPrinter Friendly DatasheetPrint This DatasheetAdd to Compare ListHave Questions? Ask UsRequest for a Quotation today

AngII elisa kit :: Mouse Angiotensin II (AngII) ELISA Kit

Scan QR to view Datasheet Catalog #    MBS2022701 (SPECIAL PROMOTION: Get FREE Starbucks gift card ($5 for 48-Wells-Kit or $10 for 96-Wells-Kit. Maximum 5 gift cards/product). Gift card(s) will be included with shipment)
Typical Testing Data/Standard Curve (for reference only)
Unit / Price
24-Strip-Wells  /  $260 +1 FREE 8GB USB
48-Strip-Wells  /  $465 +1 FREE 8GB USB
96-Strip-Wells  /  $625 +1 FREE 8GB USB
5x96-Strip-Wells  /  $2,530 +3 FREE 8GB USB
10x96-Strip-Wells  /  $4,565 +5 FREE 8GB USB
 
 Go to:   rightarrow  Product Names   rightarrow Product Info   rightarrow Accession #s   rightarrow Product Desc   rightarrow Diseases/Tissues/Pathways   rightarrow Applications   rightarrow References 
 Product Name   

Angiotensin II (AngII), ELISA Kit

★Popular Item★
 Also Known As   

Angiotensin II (AngII) ELISA Kit

 Product Synonym Names    Ang-II; Angiotensin-2
 Product Gene Name   

AngII elisa kit

[Similar Products]
 Research Use Only    For Research Use Only. Not for use in diagnostic procedures.
Table BarTOPTable Bar
  Sample Manual Insert    Download PDF Manual View PDF Manual
 Request for Current Manual Insert    Request Current Manual
 Species Reactivity    Mouse
Section Bar
 Specificity    This assay has high sensitivity and excellent specificity for detection of Angiotensin II (AngII).
No significant cross-reactivity or interference between Angiotensin II (AngII) and analogues was observed.
Section Bar
 Assay Type    Competitive Inhibition
 Samples    Serum, Plasma, Tissue homogenates, Cell lysates, Cell culture supernates and Other Biological Fluids
 Detection Range    24.69-2,000pg/mL
 Sensitivity    < 8.84pg/mL
 Application    Enzyme-linked immunosorbent assay for Antigen Detection.
 Intra-assay Precision (Precision within an assay)    3 samples with low, middle and high level Angiotensin II (AngII) were tested 20 times on one plate, respectively.
 Inter-assay Precision (Precision between assays)    3 samples with low, middle and high level Angiotensin II (AngII) were tested on 3 different plates, 8 replicates in each plate.
 CV(%) =    SD/meanX100
 Intra-Assay    CV<10%
 Inter-Assay    CV<12%
Section Bar
 Preparation and Storage    The stability of kit is determined by the loss rate of activity. The loss rate of this kit is less than 5% within the expiration date under appropriate storage condition.
To minimize extra influence on the performance, operation procedures and lab conditions, especially room temperature, air humidity, incubator temperature should be strictly controlled. It is also strongly suggested that the whole assay is performed by the same operator from the beginning to the end.
 ISO Certification    Manufactured in an ISO 9001:2015 and ISO 13485:2016 Certified Laboratory.
 Supply Chain Verification    Manufactured in a lab with traceable raw materials manufactured on site. Coordinated product portfolio of antibodies, pairs, conjugates, recombinant proteins, and immunoassay materials available. Please inquire.
 Product Note    Our ELISA Kit assays are dynamic research tools and sometimes they may be updated and improved. If the format of this assay is important to you then please request the current manual or contact our technical support team with a presales inquiry before placing an order. We will confirm the current details of the assay. We cannot guarantee the sample manual posted online is the most current manual.
 Other Notes    Small volumes of AngII elisa kit vial(s) may occasionally become entrapped in the seal of the product vial during shipment and storage. If necessary, briefly centrifuge the vial on a tabletop centrifuge to dislodge any liquid in the container`s cap. Certain products may require to ship with dry ice and additional dry ice fee may apply.
 Searchable Terms for AngII purchase    MBS2022701 is a ready-to-use microwell, strip plate Competitive Inhibition ELISA (enzyme-linked immunosorbent assay) Kit for analyzing the presence of the Angiotensin II (AngII) ELISA Kit target analytes in biological samples. The concentration gradients of the kit standards or positive controls render a theoretical kit detection range of 24.69-2,000pg/mL in biological research samples containing AngII, with an estimated sensitivity of < 8.84pg/mL. The ELISA analytical biochemical technique of the MBS2022701 kit is based on AngII antibody-AngII antigen interactions (immunosorbency) and an HRP colorimetric detection system to detect AngII antigen targets in samples. The ELISA Kit is designed to detect native, not recombinant, AngII. Appropriate sample types may include undiluted body fluids and/or tissue homogenates, secretions such as Serum, Plasma, Tissue homogenates, Cell lysates, Cell culture supernates and Other Biological Fluids. Quality control assays assessing reproducibility identified the intra-assay CV (%) and inter-assay CV(%).
Table BarTOPTable Bar
 

Related Product Information for AngII elisa kit

   This assay employs the competitive inhibition enzyme immunoassay technique. A monoclonal antibody specific to Angiotensin II (AngII) has been pre-coated onto a microplate. A competitive inhibition reaction is launched between biotin labeled Angiotensin II (AngII) and unlabeled Angiotensin II (AngII) (Standards or samples) with the pre-coated antibody specific to Angiotensin II (AngII). After incubation the unbound conjugate is washed off. Next, avidin conjugated to Horseradish Peroxidase (HRP) is added to each microplate well and incubated. The amount of bound HRP conjugate is reverse proportional to the concentration of Angiotensin II (AngII) in the sample. After addition of the substrate solution, the intensity of color developed is reverse proportional to the concentration of Angiotensin II (AngII) in the sample.
 Product Categories/Family for AngII elisa kit    Endocrinology; Cardiovascular biology
Section Bar
 Typical Testing Data/Standard Curve (for reference only) of AngII elisa kit    AngII elisa kit Typical Testing Data/Standard Curve (for reference only) image
Table BarTOPTable Bar
Sample Manual Insert of MBS2022701. Click to request current manual
Table BarTOPTable Bar
 Precautions    All of MyBioSource's Products are for scientific laboratory research purposes and are not for diagnostic, therapeutics, prophylactic or in vivo use. Through your purchase, you expressly represent and warrant to MyBioSource that you will properly test and use any Products purchased from MyBioSource in accordance with industry standards. MyBioSource and its authorized distributors reserve the right to refuse to process any order where we reasonably believe that the intended use will fall outside of our acceptable guidelines.
 Disclaimer    While every efforts were made to ensure the accuracy of the information provided in this datasheet, MyBioSource will not be liable for any omissions or errors contained herein. MyBioSource reserves the right to make changes to this datasheet at any time without prior notice.

It is the responsibility of the customer to report product performance issues to MyBioSource within 30 days of receipt of the product. Please visit our Terms & Conditions page for more information.
Table BarTOPTable Bar
horiz bar
 SSL   Follow us on Facebook Follow us onTwitter Follow us on Google Plus Connect us on LinkedIn Subscribe to our RSS Feed for latest products and special promotions