• Call +1.858.633.0165 or Fax +1.858.633.0166 or Contact Us

Nectin 2 (CD112) ELISA Kit for Human

For Research Use Only. Not for use in diagnostic procedures. Catalog #: MBS138992

This Human Nectin 2 (CD112) ELISA Kit is intended for quantitative detection of human Nectin-2/CD112 in cell culture supernates, serum and plasma (heparin, EDTA). Strip well format. Reagents for up to 96 tests.This human Nectin-2/CD112 ELISA Kit was based on… More details

$1100 / 1 Kit +1 FREE 8GB USB

Product Documentation

PDF
Sample Manual Insert View PDF
PDF
Testing Data View PDF
PDF
Certificate of Analysis (COA) View PDF
PDF
QC Report View PDF
PDF
Material Safety Data Sheet View PDF
PDF
Technical Datasheet View PDF
PDF
Protocol View PDF

Product Overview

Online Datasheet in PDF
Product Name
Nectin 2 (CD112), ELISA Kit
Full Product Name
Human Nectin 2 (CD112) ELISA Kit
Product Gene Name
Species Reactivity
Human
Assay Type
sandwich
Samples
cell culture supernates, serum and plasma (heparin, EDTA)
Detection Range
156pg/ml-10000pg/ml
Sensitivity
<0.1ng/ml
Preparation and Storage
Store at 4 degree C for 6 months, at -20 degree C for 12 months. Avoid multiple freeze-thaw cycles. (Shipped with wet ice)
Molecular Weight
51,359 Da
OMIM
X80038 mRNA
3D Structure
ModBase 3D Structure for Q92692
Detection Target
Nectin 2 (CD112)
Immunogen Sequence
333
Cross-Reactivity
There is no detectable cross-reactivity with other relevant proteins.

Other Notes

Small volumes of CD112 elisa kit vial(s) may occasionally become entrapped in the seal of the product vial during shipment and storage. If necessary, briefly centrifuge the vial on a tabletop centrifuge to dislodge any liquid in the container`s cap. Certain products may require to ship with dry ice and additional dry ice fee may apply.

Searchable Terms for CD112 purchase

MBS138992 is a ready-to-use microwell, strip-or-full plate ELISA (enzyme-linked immunosorbent assay) Kit for analyzing the presence of the Nectin 2 (CD112) ELISA Kit target analytes in biological samples. The concentration gradients of the kit standards or positive controls render a theoretical kit detection range in biological research samples containing CD112. The ELISA analytical biochemical technique of the MBS138992 kit is based on CD112 antibody-CD112 antigen interactions (immunosorbency) and an HRP colorimetric detection system to detect CD112 antigen targets in samples. The ELISA Kit is designed to detect native, not recombinant, CD112. Appropriate sample types may include undiluted body fluids and/or tissue homogenates, secretions. Quality control assays assessing reproducibility identified the intra-assay CV (%) and inter-assay CV(%).

Additional Details

NCBI/Uniprot data below describe general gene information for CD112. It may not necessarily be applicable to this product.

NCBI GI #
NCBI GeneID
NCBI Accession #
UniProt Primary Accession #
UniProt Secondary Accession #
UniProt Related Accession #
NCBI Official Full Name
Nectin-2
NCBI Official Synonym Full Names
nectin cell adhesion molecule 2
NCBI Official Symbol
NECTIN2
NCBI Official Synonym Symbols
HVEB; PRR2; CD112; PVRL2; PVRR2
UniProt Protein Name
Nectin-2
UniProt Synonym Protein Names
Herpes virus entry mediator B; Herpesvirus entry mediator B; HveB; Nectin cell adhesion molecule 2
UniProt Gene Name
NECTIN2
UniProt Synonym Gene Names
Herpesvirus entry mediator B; HveB
NCBI Protein Information
nectin-2

NCBI Summary for CD112

This gene encodes a single-pass type I membrane glycoprotein with two Ig-like C2-type domains and an Ig-like V-type domain. This protein is one of the plasma membrane components of adherens junctions. It also serves as an entry for certain mutant strains of herpes simplex virus and pseudorabies virus, and it is involved in cell to cell spreading of these viruses. Variations in this gene have been associated with differences in the severity of multiple sclerosis. Alternate transcriptional splice variants, encoding different isoforms, have been characterized. [provided by RefSeq, Jul 2008]
Show more

UniProt Comments for CD112

Modulator of T-cell signaling. Can be either a costimulator of T-cell function, or a coinhibitor, depending on the receptor it binds to. Upon binding to CD226, stimulates T-cell proliferation and cytokine production, including that of IL2, IL5, IL10, IL13, and IFNG. Upon interaction with PVRIG, inhibits T-cell proliferation. These interactions are competitive (PubMed:26755705). Probable cell adhesion protein (PubMed:9657005).
Show more

Precautions

All of MyBioSource's Products are for scientific laboratory research purposes and are not for diagnostic, therapeutics, prophylactic or in vivo use. Through your purchase, you expressly represent and warrant to MyBioSource that you will properly test and use any Products purchased from MyBioSource in accordance with industry standards. MyBioSource and its authorized distributors reserve the right to refuse to process any order where we reasonably believe that the intended use will fall outside of our acceptable guidelines.

Disclaimer

While every efforts were made to ensure the accuracy of the information provided in this datasheet, MyBioSource will not be liable for any omissions or errors contained herein. MyBioSource reserves the right to make changes to this datasheet at any time without prior notice.

It is the responsibility of the customer to report product performance issues to MyBioSource within 30 days of receipt of the product. Please visit our Terms & Conditions page for more information.

Product Note

Select online data sheet information is drawn from bioinformatics databases, occasionally resulting in ambiguous or non-relevant product information. It is the responsibility of the customer to review, verify, and evaluate the information to make sure it matches their requirements before purchasing the kit. Our ELISA Kit assays are dynamic research tools and sometimes they may be updated and improved. If the format of this assay is important to you then please request the current manual or contact our technical support team with a presales inquiry before placing an order. We will confirm the current details of the assay. We cannot guarantee the sample manual posted online is the most current manual, it is intended to serve as an example only. Please refer to the instructions For Use provided with the assay kit for precise details.

Product PubMed Publications

Request a Quote

Please fill out the form below and our representative will get back to you shortly.

MBS000000
Contact Us

Please fill out the form below and our representative will get back to you shortly.

MBS000000