Firure 1. Immunofluorescent Validation of MBS150780 in SARS-CoV-2 Infected Lung Tissue (Singh et al., Nature Microbiology, 2021)Multilabel confocal immunofluorescence microscopy of formalin-fixed paraffin-embedded lung sections from rhesus macaques infected with SARS-CoV-2. SARS-CoV-2 spike-specific antibodies, MBS150780. (k, n) (turquoise); Ki67 (magenta) and neutrophil marker CD66abce (yellow) (k); pan-macrophage marker CD68 (magenta) (n) and DAPI (blue).
Figure 2 Immunofluorescent Validation of MBS150780 in SARS-CoV-2 Infected Nose and Tonsil (Singh et al., Nature Microbiology, 2021) Multi-label confocal immunofluorescence microscopy of nasal epithelium (20X-b, 63xh) and tonsil (20X-c,63X-i) from rhesus macaques infected with SARS-CoV-2 with SARS-CoV-2 spike-specific antibodies, MBS150780. (turquoise), DAPI (blue). Rabbit IgG isotype control antibody was used to stain the tissues to rule out any nonspecific staining (e, f).
Figure 3 Immunofluorescent Validation of MBS150780 in SARS-CoV-2 Infected Lung Tissue (Singh et al., Nature Microbiology, 2021) Multilabel confocal immunofluorescence microscopy of formalin-fixed paraffin-embedded lung sections from rhesus macaques infected with SARS-CoV-2. SARS-CoV-2 spike-specific antibodies, MBS150780. (k-s) (turquoise); Ki67 (magenta) and neutrophil marker CD66abce (yellow) (k-m); pan-macrophage marker CD68 (magenta) (n-p); HLA-DR (magenta) and pDC marker CD123 (yellow) (q–s) and DAPI (blue).
Figure 4 Immunohistochemistry Validation of SARSCoV-2 (COVID-19) Spike in COVID-19 Patient Lung Immunohistochemical analysis of paraffin-embedded COVID-19 patient lung tissue using anti-SARS-CoV-2 (COVID-19) Spike S2 antibody (MBS150780, 0.5 ug/mL). Tissue was fixed with formaldehyde and blocked with 10% serum for 1 h at RT; antigen retrieval was by heat mediation with a citrate buffer (pH6). Samples were incubated with primary antibody overnight at 4°C. A goat anti-rabbit IgG H&L (HRP) at 1/250 was used as secondary. Counter stained with Hematoxylin. Strong spike protein signal was observed in macrophages and airway epithelium of COVID-19 patient lung, but not in non-COVID-19 patient lung.
Figure 5 Immunohistochemistry Validation of SARSCoV-2 (COVID-19) Spike in COVID-19 Patient Lung Immunohistochemical analysis of paraffin-embedded COVID-19 patient lung tissue using anti-SARS-CoV-2 (COVID-19) Spike S2 antibody (MBS150780, 0.5 ug/mL). Tissue was fixed with formaldehyde and blocked with 10% serum for 1 h at RT; antigen retrieval was by heat mediation with a citrate buffer (pH6). Samples were incubated with primary antibody overnight at 4°C. A goat anti-rabbit IgG H&L (HRP) at 1/250 was used as secondary. Counter stained with Hematoxylin. Strong spike protein signal wasobserved in macrophages of COVID-19 patient lung.
Figure 6 IHC/IF Validation in COVID-19 Patient Sample (Nuovo et al., 2020) Detection of SARS-CoV-2 proteins in nasopharyngeal swab cell preparations. B. An intense signal for covid-19 spike protein tested by SARS-CoV-2 spike antibodies (MBS150780) was observed in the glandular cells. F-H. Co-expression of spike detected by spike antibodies (MBS150780, 0.2 ug/mL) and envelope proteins detected by envelope antibodies (
MBS150849, 2 ug/mL) of SARSCoV- 2 (F) documented localization of each protein to glandular cells (G, yellow). No signal was seen in oral swabs of positive cases (H). Both the spike and envelope protein detected by anti-spike antibodies (MBS150780) and anti-envelope antibodies (
MBS150849,) produced a signal in the nasopharyngeal swabs of the three cases and no signal was evident in the nasopharyngeal swabs of the seven controls.
Figure 7 IF Validation of SARS-CoV2 Spike in COVID-19 Patient Lung (Magro et al., 2020) SARS-CoV2 spike protein (red, panel C) detected by anti-spike antibodies (MBS150780, 0.2 ug/mL) colocalized with C4d (green in panel d, merged in yellow). Spike protein (red, panel g) was also colocalized with C5b-9 (green in panel f&h, merged in yellow)
Figure 8 IF Validation of SARS-CoV2 Spike in COVID-19 Patient Skin (Magro et al., 2020) C4d is highlighted green while COVID-19 spike protein detected by anti-spike antibodies (MBS150780, 0.2 ug/mL) shows a red staining pattern; a yellow signal is discernible indicative of co-localization of C4d and viral protein within the microvasculature.
Figure 9 IHC Validation of SARS-CoV2 Spike in the Nasopharyngeal Swab Sample of the COVID-19 Patient Strong spike signal was detected by anti-spike antibodies (MBS150780, 0.2 ug/mL) in the nasopharyngeal swab sample of the COVID-19 patient and no spike signal was observed in the sample of the COVID-19 negative patient. COVID-19 cases were confirmed by PCR. (Courtesy of Dr. Nuovo Gerard J., OSU)
Figure 10 IHC Validation of SARS-CoV2 Spike in COVID-19 Patient Lung Strong spike signal was detected by anti-spike antibodies (MBS150780, 0.2 ug/mL) in the lung of the COVID-19 patient confirmed by PCR. (Courtesy of Dr. Nuovo Gerard J., OSU)
Figure 11 IHC Validation of SARS-CoV2 Spike in COVID-19 Patient Brain Spike protein was detected by anti-spike antibodies (MBS150780, 0.2 ug/mL) in the brain of the COVID-19 patient confirmed by PCR. (Courtesy of Dr. Nuovo Gerard J., OSU)
Figure 12 Overexpression Validation in Spike Transfected 293 Cells Loading: 15 ug per lane of 293 cell lysate. Antibodies: SARS-CoV-2 (COVID-19) Spike, MBS150780 (1 ug/mL), 1h incubation at RT in 5% NFDM/TBST. Secondary: Goat anti rabbit IgG HRP conjugate at 1:10000 dilution. Lane 1: WT293 cells and Lane 2: SARS-CoV-2 Spike overexpressed 293 cells.