• Call +1.858.633.0165 or Fax +1.858.633.0166 or Contact Us

Catalase (CAT) ELISA Kit for Rat

For Research Use Only. Not for use in diagnostic procedures. Catalog #: MBS166257

Intended Uses: This sandwich kit is for the accurate quantitative detection of Rat Carboxyhemoglobin (also known as HBCO) in serum, plasma, cell culture supernates, cell lysates, tissue homogenates.Principles of the Assay: This kit is an Enzyme-Linked… More details

$445 / 48-Strip-Wells +1 FREE 8GB USB

Product Documentation

PDF
Sample Manual Insert View PDF
PDF
Testing Data View PDF
PDF
Certificate of Analysis (COA) View PDF
PDF
QC Report View PDF
PDF
Material Safety Data Sheet View PDF
PDF
Technical Datasheet View PDF
PDF
Protocol View PDF

Product Overview

Online Datasheet in PDF
Product Name
Catalase (CAT), ELISA Kit
Full Product Name
Rat Catalase (CAT) ELISA Kit
Product Gene Name
Species Reactivity
Rat
Assay Type
Quantitative Sandwich
Samples
Serum, plasma, cell culture supernates, cell lysates, tissue homogenates
Detection Range
0.05?g/L - 10?g/L
Sensitivity
0.01?g/L
Preparation and Storage
Store at 2 to 8 degree C for 6 months.
Molecular Weight
56,466 Da
3D Structure
ModBase 3D Structure for P12365
Intra-Assay
CV<8%
Inter-Assay
CV<10%
ISO Certification
Manufactured in an ISO 9001:2015 Certified Laboratory.

Typical Testing Data/Standard Curve (for reference only) of CAT elisa kit

Rat CAT ELISA Kit – Cat# MBS166257

Other Notes

Small volumes of CAT elisa kit vial(s) may occasionally become entrapped in the seal of the product vial during shipment and storage. If necessary, briefly centrifuge the vial on a tabletop centrifuge to dislodge any liquid in the container`s cap. Certain products may require to ship with dry ice and additional dry ice fee may apply.

Searchable Terms for CAT purchase

MBS166257 is a ready-to-use microwell, strip plate ELISA (enzyme-linked immunosorbent assay) Kit for analyzing the presence of the Catalase (CAT) ELISA Kit target analytes in biological samples. The concentration gradients of the kit standards or positive controls render a theoretical kit detection range in biological research samples containing CAT. The ELISA analytical biochemical technique of the MBS166257 kit is based on CAT antibody-CAT antigen interactions (immunosorbency) and an HRP colorimetric detection system to detect CAT antigen targets in samples. The ELISA Kit is designed to detect native, not recombinant, CAT. Appropriate sample types may include undiluted body fluids and/or tissue homogenates, secretions. Quality control assays assessing reproducibility identified the intra-assay CV (%) and inter-assay CV(%).

Additional Details

NCBI/Uniprot data below describe general gene information for CAT. It may not necessarily be applicable to this product.

NCBI GI #
NCBI GeneID
NCBI Accession #
UniProt Primary Accession #
UniProt Related Accession #
NCBI Official Full Name
catalase
NCBI Official Symbol
cat2
NCBI Official Synonym Symbols
Ct2; Cat0; ncr(cat2); GRMZM2G090568
UniProt Protein Name
Catalase isozyme 2
UniProt Gene Name
CAT2
NCBI Protein Information
catalase isozyme 2

UniProt Comments for CAT

Occurs in almost all aerobically respiring organisms and serves to protect cells from the toxic effects of hydrogen peroxide.

Precautions

All of MyBioSource's Products are for scientific laboratory research purposes and are not for diagnostic, therapeutics, prophylactic or in vivo use. Through your purchase, you expressly represent and warrant to MyBioSource that you will properly test and use any Products purchased from MyBioSource in accordance with industry standards. MyBioSource and its authorized distributors reserve the right to refuse to process any order where we reasonably believe that the intended use will fall outside of our acceptable guidelines.

Disclaimer

While every efforts were made to ensure the accuracy of the information provided in this datasheet, MyBioSource will not be liable for any omissions or errors contained herein. MyBioSource reserves the right to make changes to this datasheet at any time without prior notice.

It is the responsibility of the customer to report product performance issues to MyBioSource within 30 days of receipt of the product. Please visit our Terms & Conditions page for more information.

Product Note

Select online data sheet information is drawn from bioinformatics databases, occasionally resulting in ambiguous or non-relevant product information. It is the responsibility of the customer to review, verify, and evaluate the information to make sure it matches their requirements before purchasing the kit. Our ELISA Kit assays are dynamic research tools and sometimes they may be updated and improved. If the format of this assay is important to you then please request the current manual or contact our technical support team with a presales inquiry before placing an order. We will confirm the current details of the assay. We cannot guarantee the sample manual posted online is the most current manual, it is intended to serve as an example only. Please refer to the instructions For Use provided with the assay kit for precise details.

Product PubMed Publications

Request a Quote

Please fill out the form below and our representative will get back to you shortly.

MBS000000
Contact Us

Please fill out the form below and our representative will get back to you shortly.

MBS000000