• Call +1.858.633.0165 or Fax +1.858.633.0166 or Contact Us

MRE11 Antibody – Rabbit Polyclonal

For Research Use Only. Not for use in diagnostic procedures. Catalog #: MBS1750471

Description: Double-strand break repair protein MRE11A is a protein that in humans is encoded by the MRE11A gene. This gene encodes a nuclear protein involved in homologous Recombinantion, telomere length maintenance, and DNA double-strand break repair. By… More details

$210 / 0.01 mg +1 FREE 8GB USB
Product Documentation
PDF
Sample Manual Insert View PDF
PDF
Testing Data View PDF
PDF
Certificate of Analysis (COA) View PDF
PDF
QC Report View PDF
PDF
Material Safety Data Sheet View PDF
PDF
Technical Datasheet View PDF
PDF
Protocol View PDF

Product Overview

Online Datasheet in PDF
Product Name
MRE11, Polyclonal Antibody
Full Product Name
Anti-MRE11 Picoband antibody
Product Gene Name
Product Synonym Names
Double-strand break repair protein MRE11; Double-strand break repair protein MRE11A; Meiotic Recombinantion 11 homolog 1; MRE11 homolog 1; Meiotic Recombinantion 11 homolog A; MRE11 homolog A; MRE11
Clonality
Polyclonal
Host
Rabbit
Species Reactivity
Human, Mouse, Rat
No cross reactivity with other proteins.
Form/Format
Lyophilized
Preparation and Storage
Store at -20 degree C for one year. After reconstitution, at 4 degree C for one month. It can also be aliquotted and stored frozen at -20 degree C for a longer time. Avoid repeated freezing and thawing.
Molecular Weight
81,070 Da
OMIM
U37359 mRNA
3D Structure
ModBase 3D Structure for P49959
Immunogen
E Coli-derived human MRE11 recombinant protein (Position: S2-D239).
Subcellular Localization
Nucleus.
Reconstitution
Add 0.2ml of distilled water will yield a concentration of 500ug/ml.
Contents
Each vial contains 4mg Trehalose, 0.9mg NaCl, 0.2mg Na2HPO4, 0.05mg NaN3.
ISO Certification
Manufactured in an ISO 13485:2003 and EN ISO 13485:2012 Certified Laboratory.
Applications Tested/Suitable for anti-MRE11 antibody
ELISA (EIA), Immunohistochemistry (IHC), Western Blot (WB)
Application Notes for anti-MRE11 antibody
WB: 0.1-0.5mug/ml
Immunohistochemistry (Paraffin-embedded Section): 0.5-1mug/ml
Direct ELISA: 0.1-0.5mug/ml

Western Blot (WB) of anti-MRE11 antibody

Figure 1. Western blot analysis of MRE11 using anti-MRE11 antibody (MBS1750471).
Electrophoresis was performed on a 5-20% SDS-PAGE gel at 70V (Stacking gel) / 90V (Resolving gel) for 2-3 hours. The sample well of each lane was loaded with 50ug of sample under reducing conditions.
Lane 1: human Hela whole cell lysates,
Lane 2: human MCF-7 whole cell lysates,
Lane 3: human COLO-320 whole cell lysates,
Lane 4: human U-87MG whole cell lysates,
Lane 5: rat brain tissue lysates,
Lane 6: rat liver tissue lysates,
Lane 7: mouse brain tissue lysates,
Lane 8: mouse liver tissue lysates.
After Electrophoresis, proteins were transferred to a Nitrocellulose membrane at 150mA for 50-90 minutes. Blocked the membrane with 5% Non-fat Milk/ TBS for 1.5 hour at RT. The membrane was incubated with rabbit anti-MRE11 antigen affinity purified polyclonal antibody at 0.5ug/mL overnight at 4 degree C, then washed with TBS-0.1%Tween 3 times with 5 minutes each and probed with a goat anti-rabbit IgG-HRP secondary antibody at a dilution of 1:10000 for 1.5 hour at RT. The signal is developed using an Enhanced Chemiluminescent detection (ECL) kit with Tanon 5200 system. A specific band was detected for MRE11 at approximately 81KD. The expected band size for MRE11 is at 81KD.
Rabbit Anti-MRE11 Polyclonal Antibody – Cat# MBS1750471

Immunohistochemistry (IHC) of anti-MRE11 antibody

Figure 2. IHC analysis of MRE11 using anti-MRE11 antibody (MBS1750471).
MRE11 was detected in paraffin-embedded section of human colon cancer tissue. Heat mediated antigen retrieval was performed in citrate buffer (pH6, epitope retrieval solution) for 20 mins. The tissue section was blocked with 10% goat serum. The tissue section was then incubated with 1ug/ml rabbit anti-MRE11 Antibody (MBS1750471) overnight at 4 degree C. Biotinylated goat anti-rabbit IgG was used as secondary antibody and incubated for 30 minutes at 37 degree C. The tissue section was developed using Strepavidin-Biotin-Complex (SABC) with DAB as the chromogen.
Rabbit Anti-MRE11 Polyclonal Antibody, Immunohistochemistry (IHC) – Cat# MBS1750471

Immunohistochemistry (IHC) of anti-MRE11 antibody

Figure 3. IHC analysis of MRE11 using anti-MRE11 antibody (MBS1750471).
MRE11 was detected in paraffin-embedded section of human lung cancer tissue. Heat mediated antigen retrieval was performed in citrate buffer (pH6, epitope retrieval solution) for 20 mins. The tissue section was blocked with 10% goat serum. The tissue section was then incubated with 1ug/ml rabbit anti-MRE11 Antibody (MBS1750471) overnight at 4 degree C. Biotinylated goat anti-rabbit IgG was used as secondary antibody and incubated for 30 minutes at 37 degree C. The tissue section was developed using Strepavidin-Biotin-Complex (SABC) with DAB as the chromogen.
Rabbit Anti-MRE11 Polyclonal Antibody, Immunohistochemistry (IHC) – Cat# MBS1750471

Immunohistochemistry (IHC) of anti-MRE11 antibody

Figure 4. IHC analysis of MRE11 using anti-MRE11 antibody (MBS1750471).
MRE11 was detected in paraffin-embedded section of human mammary cancer tissue. Heat mediated antigen retrieval was performed in citrate buffer (pH6, epitope retrieval solution) for 20 mins. The tissue section was blocked with 10% goat serum. The tissue section was then incubated with 1ug/ml rabbit anti-MRE11 Antibody (MBS1750471) overnight at 4 degree C. Biotinylated goat anti-rabbit IgG was used as secondary antibody and incubated for 30 minutes at 37 degree C. The tissue section was developed using Strepavidin-Biotin-Complex (SABC) with DAB as the chromogen.
Rabbit Anti-MRE11 Polyclonal Antibody, Immunohistochemistry (IHC) – Cat# MBS1750471

Other Notes

Small volumes of anti-MRE11 antibody vial(s) may occasionally become entrapped in the seal of the product vial during shipment and storage. If necessary, briefly centrifuge the vial on a tabletop centrifuge to dislodge any liquid in the container`s cap. Certain products may require to ship with dry ice and additional dry ice fee may apply.

Searchable Terms for MRE11 purchase

MBS1750471 is an antibody targeting MRE11. Also known as Anti-MRE11 Picoband antibody. Reactive in Human, Mouse, Rat
No cross reactivity with other proteins.. Host: Rabbit.

Additional Details

NCBI/Uniprot data below describe general gene information for MRE11. It may not necessarily be applicable to this product.

NCBI GI #
NCBI GeneID
NCBI Accession #
UniProt Primary Accession #
UniProt Secondary Accession #
UniProt Related Accession #
GenBank Nucleotide #
NCBI Official Full Name
double-strand break repair protein MRE11 isoform 2
NCBI Official Synonym Full Names
MRE11 homolog, double strand break repair nuclease
NCBI Official Symbol
MRE11
NCBI Official Synonym Symbols
ATLD; HNGS1; MRE11A; MRE11B
UniProt Protein Name
Double-strand break repair protein MRE11
UniProt Synonym Protein Names
Double-strand break repair protein MRE11A; Meiotic recombination 11 homolog 1; MRE11 homolog 1; Meiotic recombination 11 homolog A; MRE11 homolog A
UniProt Gene Name
MRE11
UniProt Synonym Gene Names
MRE11 homolog 1; MRE11 homolog A
NCBI Protein Information
double-strand break repair protein MRE11; double-strand break repair protein MRE11A

NCBI Summary for MRE11

This gene encodes a nuclear protein involved in homologous recombination, telomere length maintenance, and DNA double-strand break repair. By itself, the protein has 3' to 5' exonuclease activity and endonuclease activity. The protein forms a complex with the RAD50 homolog; this complex is required for nonhomologous joining of DNA ends and possesses increased single-stranded DNA endonuclease and 3' to 5' exonuclease activities. In conjunction with a DNA ligase, this protein promotes the joining of noncomplementary ends in vitro using short homologies near the ends of the DNA fragments. This gene has a pseudogene on chromosome 3. Alternative splicing of this gene results in two transcript variants encoding different isoforms. [provided by RefSeq, Jul 2008]
Show more

UniProt Comments for MRE11

Component of the MRN complex, which plays a central role in double-strand break (DSB) repair, DNA recombination, maintenance of telomere integrity and meiosis. The complex possesses single-strand endonuclease activity and double-strand-specific 3'-5' exonuclease activity, which are provided by MRE11. RAD50 may be required to bind DNA ends and hold them in close proximity. This could facilitate searches for short or long regions of sequence homology in the recombining DNA templates, and may also stimulate the activity of DNA ligases and/or restrict the nuclease activity of MRE11 to prevent nucleolytic degradation past a given point (PubMed:9651580, PubMed:9590181, PubMed:9705271, PubMed:11741547). The complex may also be required for DNA damage signaling via activation of the ATM kinase (PubMed:15064416). In telomeres the MRN complex may modulate t-loop formation (PubMed:10888888).
Show more

Precautions

All of MyBioSource's Products are for scientific laboratory research purposes and are not for diagnostic, therapeutics, prophylactic or in vivo use. Through your purchase, you expressly represent and warrant to MyBioSource that you will properly test and use any Products purchased from MyBioSource in accordance with industry standards. MyBioSource and its authorized distributors reserve the right to refuse to process any order where we reasonably believe that the intended use will fall outside of our acceptable guidelines.

Disclaimer

While every efforts were made to ensure the accuracy of the information provided in this datasheet, MyBioSource will not be liable for any omissions or errors contained herein. MyBioSource reserves the right to make changes to this datasheet at any time without prior notice.

It is the responsibility of the customer to report product performance issues to MyBioSource within 30 days of receipt of the product. Please visit our Terms & Conditions page for more information.

Product Note

Select online data sheet information is drawn from bioinformatics databases, occasionally resulting in ambiguous or non-relevant product information. It is the responsibility of the customer to review, verify, and evaluate the information to make sure it matches their requirements before purchasing the kit. Our ELISA Kit assays are dynamic research tools and sometimes they may be updated and improved. If the format of this assay is important to you then please request the current manual or contact our technical support team with a presales inquiry before placing an order. We will confirm the current details of the assay. We cannot guarantee the sample manual posted online is the most current manual, it is intended to serve as an example only. Please refer to the instructions For Use provided with the assay kit for precise details.

Product PubMed Publications

Request a Quote

Please fill out the form below and our representative will get back to you shortly.

MBS000000
Contact Us

Please fill out the form below and our representative will get back to you shortly.

MBS000000