• Call +1.858.633.0165 or Fax +1.858.633.0166 or Contact Us

COX8A Antibody – Rabbit Polyclonal

For Research Use Only. Not for use in diagnostic procedures. Catalog #: MBS1753830

The protein encoded by this gene is the terminal enzyme of the respiratory chain, coupling the transfer of electrons from cytochrome c to molecular oxygen, with the concomitant production of a proton electrochemical gradient across the inner mitochondrial… More details

$475 / 0.1 mg +1 FREE 8GB USB
Product Documentation
PDF
Sample Manual Insert View PDF
PDF
Testing Data View PDF
PDF
Certificate of Analysis (COA) View PDF
PDF
QC Report View PDF
PDF
Material Safety Data Sheet View PDF
PDF
Technical Datasheet View PDF
PDF
Protocol View PDF

Product Overview

Online Datasheet in PDF
Product Name
COX8A, Polyclonal Antibody
Full Product Name
Anti-COX8A Antibody
Product Gene Name
Product Synonym Names
Cox8a; Cox8; Cox8l; Cytochrome c oxidase subunit 8A, mitochondrial; Cytochrome c oxidase polypeptide VIII-liver; Cytochrome c oxidase subunit 8-2; cytochrome c oxidase subunit 8A
Clonality
Polyclonal
Isotype
Rabbit IgG
Host
Rabbit
Species Reactivity
Mouse, Rat
Form/Format
Each vial contains 4 mg Trehalose, 0.9 mg NaCI, 0.2mg Na2HPO4,0.01mg NaN3
Purity/Purification
Immunogen affinity purified.
Concentration
500 ug/ml (lot specific)
Specificity
Rabbit IgG polyclonal antibody for COX8A detection.
Preparation and Storage
Store at -20 degree C for one year and at 4 degree C for one month. Avoid repeated freezing and thawing.
3D Structure
ModBase 3D Structure for Q64445
Immunogen
A synthetic peptide corresponding to a sequence of mouse COX8A (AGWILSHLETYRRPE).
Reconstitution
Add 0.2ml of distilled water will yield a concentration of 500ug/ml.
ISO Certification
Manufactured in an ISO 13485:2003 and EN ISO 13485:2012 Certified Laboratory.
Applications Tested/Suitable for anti-Cox8a antibody
Western Blot (WB), Immunohistochemistry-Paraffin (IHC-P), Flow Cytometry (FC/FACS/FCM) (Fixed)
Application Notes for anti-Cox8a antibody
Western Blot (WB):
Concentration: 0.25-0.5 ug/ml; Tested Species: Mouse, Rat

Immunohistochemistry (IHC):
Concentration: 2-5 ug/ml; Tested Species: Rat

Flow Cytometry (Fixed):
Concentration: 1-3 ug/1x106 cells; Tested Species: Mouse

Optimal dilutions should be determined by the end users

Western Blot (WB) of anti-Cox8a antibody

Figure 1. Western blot analysis of COX8A using anti-COX8A antibody (MBS1753830).
Electrophoresis was performed on a 5-20% SDS-PAGE gel at 70V (Stacking gel) / 90V (Resolving gel) for 2-3 hours. The sample well of each lane was loaded with 50ug of sample under reducing conditions.
Lane 1: rat brain tissue lysates
Lane 2: rat stomach tissue lysates
Lane 3: rat kidney tissue lysates
Lane 4: mouse brain tissue lysates
Lane 5: mouse kidney tissue lysates.
After Electrophoresis, proteins were transferred to a Nitrocellulose membrane at 150mA for 50-90 minutes. Blocked the membrane with 5% Non-fat Milk/ TBS for 1. 5 hour at RT. The membrane was incubated with rabbit anti-COX8A antigen affinity purified polyclonal antibody (Catalog # MBS1753830) at 0. 5 μg/mL overnight at 4 degree C, then washed with TBS-0. 1%Tween 3 times with 5 minutes each and probed with a goat anti-rabbit IgG-HRP secondary antibody at a dilution of 1:5000 for 1. 5 hour at RT. The signal is developed using an Enhanced Chemiluminescent detection (ECL) kit (Catalog # MBS176460) with Tanon 5200 system. A specific band was detected for COX8A at approximately 8-10KD. The expected band size for COX8A is at 8-10KD.
Rabbit Anti-COX8A Polyclonal Antibody – Cat# MBS1753830

Flow Cytometry (FC/FACS) of anti-Cox8a antibody

Figure 2. Flow Cytometry analysis of mouse spleen tissues using anti-COX8A antibody (MBS17538302).
Overlay histogram showing mouse spleen tissues stained with MBS1753830 (Blue line). The tissues were blocked with 10% normal goat serum. And then incubated with rabbit anti-COX8A Antibody (MBS1753830, 1μg/1x106 cells) for 30 min at 20 degree C. DyLight®488 conjugated goat anti-rabbit IgG (5-10μg/1x106 cells) was used as secondary antibody for 30 minutes at 20 degree C. Isotype control antibody (Green line) was rabbit IgG (1μg/1x106) used under the same conditions. Unlabelled sample (Red line) was also used as a control.
Rabbit Anti-COX8A Polyclonal Antibody, Flow Cytometry (FC/FACS) – Cat# MBS1753830

Immunohistochemistry (IHC) of anti-Cox8a antibody

Figure 3. IHC analysis of COX8A using anti-COX8A antibody (MBS1753830).
COX8A was detected in paraffin-embedded section of rat testis tissue. Heat mediated antigen retrieval was performed in EDTA buffer (pH8. 0, epitope retrieval solution). The tissue section was blocked with 10% goat serum. The tissue section was then incubated with 2μg/ml rabbit anti-COX8A Antibody (MBS1753830) overnight at 4 degree C. Biotinylated goat anti-rabbit IgG was used as secondary antibody and incubated for 30 minutes at 37 degree C. The tissue section was developed using Strepavidin-Biotin-Complex (SABC) (Catalog # MBS176451) with DAB as the chromogen.
Rabbit Anti-COX8A Polyclonal Antibody, Immunohistochemistry (IHC) – Cat# MBS1753830

Product References and Citations for anti-Cox8a antibody

1. Courseaux, A., Grosgeorge, J., Gaudray, P., Pannett, A. A. J., Forbes, S. A., Williamson, C., Bassett, D., Thakker, R. V., Teh, B. T., Farnebo, F., Shepherd, J., Skogseid, B., Larsson, C., Giraud, S., Zhang, C. X., Salandre, J., Calender, A. Definition of the minimal MEN1 candidate area based on a 5-Mb integrated map of proximal 11q13. Genomics 37: 354-365, 1996.
2. Hallmann, K., Kudin, A. P., Zsurka, G., Kornblum, C., Reimann, J., Stuve, B., Waltz, S., Hattingen, E., Thiele, H., Nurnberg, P., Rub, C., Voos, W., Kopatz, J., Neumann, H., Kunz, W. S. Loss of the smallest subunit of cytochrome c oxidase, COX8A, causes Leigh-like syndrome and epilepsy. Brain 139: 338-345, 2016.
3. Richard, C. W., Withers, D. A., Meeker, T. C., Myers, R. M. A radiation hybrid map of the proximal long arm of human chromosome 11 containing the MEN-1 and bcl-1 disease locus. (Abstract) Cytogenet. Cell Genet. 58: 1970 only, 1991.

Other Notes

Small volumes of anti-Cox8a antibody vial(s) may occasionally become entrapped in the seal of the product vial during shipment and storage. If necessary, briefly centrifuge the vial on a tabletop centrifuge to dislodge any liquid in the container`s cap. Certain products may require to ship with dry ice and additional dry ice fee may apply.

Searchable Terms for Cox8a purchase

MBS1753830 is an antibody targeting Cox8a. Reactive in Mouse, Rat. Host: Rabbit.

Additional Details

NCBI/Uniprot data below describe general gene information for Cox8a. It may not necessarily be applicable to this product.

NCBI GI #
NCBI GeneID
NCBI Accession #
UniProt Primary Accession #
UniProt Secondary Accession #
UniProt Related Accession #
GenBank Nucleotide #
NCBI Official Full Name
cytochrome c oxidase subunit 8A, mitochondrial
NCBI Official Synonym Full Names
cytochrome c oxidase subunit VIIIa
NCBI Official Symbol
Cox8a
NCBI Official Synonym Symbols
COX8L
UniProt Protein Name
Cytochrome c oxidase subunit 8A, mitochondrial
UniProt Synonym Protein Names
Cytochrome c oxidase polypeptide VIII-liver; Cytochrome c oxidase subunit 8-2
UniProt Gene Name
Cox8a
UniProt Synonym Gene Names
Cox8; Cox8l
UniProt Entry Name
COX8A_MOUSE
NCBI Protein Information
cytochrome c oxidase subunit 8A, mitochondrial; COX VIII-L; cytochrome c oxidase subunit 8-2; cytochrome c oxidase polypeptide VIII-liver

Precautions

All of MyBioSource's Products are for scientific laboratory research purposes and are not for diagnostic, therapeutics, prophylactic or in vivo use. Through your purchase, you expressly represent and warrant to MyBioSource that you will properly test and use any Products purchased from MyBioSource in accordance with industry standards. MyBioSource and its authorized distributors reserve the right to refuse to process any order where we reasonably believe that the intended use will fall outside of our acceptable guidelines.

Disclaimer

While every efforts were made to ensure the accuracy of the information provided in this datasheet, MyBioSource will not be liable for any omissions or errors contained herein. MyBioSource reserves the right to make changes to this datasheet at any time without prior notice.

It is the responsibility of the customer to report product performance issues to MyBioSource within 30 days of receipt of the product. Please visit our Terms & Conditions page for more information.

Product Note

Select online data sheet information is drawn from bioinformatics databases, occasionally resulting in ambiguous or non-relevant product information. It is the responsibility of the customer to review, verify, and evaluate the information to make sure it matches their requirements before purchasing the kit. Our ELISA Kit assays are dynamic research tools and sometimes they may be updated and improved. If the format of this assay is important to you then please request the current manual or contact our technical support team with a presales inquiry before placing an order. We will confirm the current details of the assay. We cannot guarantee the sample manual posted online is the most current manual, it is intended to serve as an example only. Please refer to the instructions For Use provided with the assay kit for precise details.

Product PubMed Publications

Request a Quote

Please fill out the form below and our representative will get back to you shortly.

MBS000000
Contact Us

Please fill out the form below and our representative will get back to you shortly.

MBS000000