• Call +1.858.633.0165 or Fax +1.858.633.0166 or Contact Us

RPL13A Antibody – Mouse Monoclonal

For Research Use Only. Not for use in diagnostic procedures. Catalog #: MBS1754023

60S ribosomal protein L13a is a protein that in humans is encoded by the RPL13A gene. It is mapped to 19q13. 33. Ribosomes, the organelles that catalyze protein synthesis, consist of a small 40S subunit and a large 60S subunit. Together these subunits… More details

$210 / 0.01 mg +1 FREE 8GB USB
Product Documentation
PDF
Sample Manual Insert View PDF
PDF
Testing Data View PDF
PDF
Certificate of Analysis (COA) View PDF
PDF
QC Report View PDF
PDF
Material Safety Data Sheet View PDF
PDF
Technical Datasheet View PDF
PDF
Protocol View PDF

Product Overview

Online Datasheet in PDF
Product Name
RPL13A, Monoclonal Antibody
Full Product Name
Anti-RPL13A Antibody (monoclonal, 4C9)
Product Gene Name
Product Synonym Names
60S ribosomal protein L13a; 23 kDa highly basic protein; Large ribosomal subunit protein Ul13; RPL13A; ribosomal protein L13a
Clonality
Monoclonal
Isotype
Mouse IgG2a
Clone Number
4C9
Host
Mouse
Species Reactivity
Human
Form/Format
Lyophilized. Each vial contains 4mg Trehalose, 0.9mg NaCl and 0.2mg Na2HPO4.
Purity/Purification
Immunogen affinity purified.
Specificity
Mouse IgG monoclonal antibody for RPL13A detection.
Preparation and Storage
Store at -20 degree C for one year. After reconstitution, at 4 degree C for one month. It can also be aliquotted and stored frozen at -20 degree C for a longer time. Avoid repeated freezing and thawing.
Molecular Weight
23,577 Da
3D Structure
ModBase 3D Structure for P40429
Immunogen
E Coli-derived human RPL13A recombinant protein (Position:A2-V203).
Reconstitution
Add 0.2ml of distilled water will yield a concentration of 500ug/ml.
Recommended Detection Systems
Recommended Detection Systems||Lab recommends Enhanced Chemiluminescent Kit with anti-Mouse IgG (MBS176445) for Western blot, and HRP Conjugated anti-Mouse IgG Super Vision Assay Kit (MBS176472) for and ICC.
ISO Certification
Manufactured in an ISO 13485:2003 and EN ISO 13485:2012 Certified Laboratory.
Applications Tested/Suitable for anti-RPL13A antibody
Western Blot (WB), Immunocytochemistry (ICC), Immunofluorescence (IF), Flow Cytometry (FC/FACS/FCM)
Application Notes for anti-RPL13A antibody
WB: 0.25-0.5ug/ml|Human|
ICC/IF: 5ug/ml|Human|
FC/FACS/FCM: 1-3ug/1x106 cells|Human|

Western Blot (WB) of anti-RPL13A antibody

Figure 1. Western blot analysis of RPL13A using anti-RPL13A antibody (MBS1754023).
Electrophoresis was performed on a 5-20% SDS-PAGE gel at 70V (Stacking gel) / 90V (Resolving gel) for 2-3 hours. The sample well of each lane was loaded with 30ug of sample under reducing conditions.
Lane 1: human Hek293 whole cell lysates
Lane 2: human Hela whole cell lysates
Lane 3: human K562 whole cell lysates.
After Electrophoresis, proteins were transferred to a Nitrocellulose membrane at 150mA for 50-90 minutes. Blocked the membrane with 5% Non-fat Milk/ TBS for 1. 5 hour at RT. The membrane was incubated with mouse anti- RPL13A antigen affinity purified monoclonal antibody (Catalog # MBS1754023) at 0. 5 μg/mL overnight at 4 degree C, then washed with TBS-0. 1%Tween 3 times with 5 minutes each and probed with a goat anti-mouse IgG-HRP secondary antibody at a dilution of 1:10000 for 1. 5 hour at RT. The signal is developed using an Enhanced Chemiluminescent detection (ECL) kit (Catalog # MBS176445) with Tanon 5200 system. A specific band was detected for RPL13A at approximately 24KD. The expected band size for RPL13A is at 24KD.
Mouse Anti-RPL13A Monoclonal Antibody – Cat# MBS1754023

Immunofluorescence (IF) of anti-RPL13A antibody

Figure 2. IF analysis of RPL13A using anti- RPL13A antibody (MBS1754023).
RPL13A was detected in immunocytochemical section of CACO-2 cells. Enzyme antigen retrieval was performed using IHC enzyme antigen retrieval reagent (MBS176582) for 15 mins. The cells were blocked with 10% goat serum. And then incubated with 5μg/mL mouse anti- RPL13A Antibody (MBS1754023) overnight at 4 degree C. DyLight®488 Conjugated Goat Anti-Mouse IgG (BA1126) was used as secondary antibody at 1:100 dilution and incubated for 30 minutes at 37 degree C. The section was counterstained with DAPI. Visualize using a fluorescence microscope and filter sets appropriate for the label used.
Mouse Anti-RPL13A Monoclonal Antibody, Immunofluorescence (IF) – Cat# MBS1754023

Flow Cytometry (FC/FACS) of anti-RPL13A antibody

Figure 3. Flow Cytometry analysis of A431 cells using anti-RPL13A antibody (MBS1754023).
Overlay histogram showing A431 cells stained with MBS1754023 (Blue line). The cells were blocked with 10% normal goat serum. And then incubated with mouse anti-RPL13A Antibody (MBS1754023, 1μg/1x106 cells) for 30 min at 20 degree C. DyLight®488 conjugated goat anti-mouse IgG (BA1126, 5-10μg/1x106 cells) was used as secondary antibody for 30 minutes at 20 degree C. Isotype control antibody (Green line) was mouse IgG (1μg/1x106) used under the same conditions. Unlabelled sample (Red line) was also used as a control.
Mouse Anti-RPL13A Monoclonal Antibody, Flow Cytometry (FC/FACS) – Cat# MBS1754023

Product References and Citations for anti-RPL13A antibody

1. Wool IG, Chan YL, Glück A (1996). "Structure and evolution of mammalian ribosomal proteins". Biochem. Cell Biol. 73 (11-12): 933-947.
2. Price SR, Nightingale MS, Bobak DA, et al. (1993). "Conservation of a 23-kDa human transplantation antigen in mammalian species". Genomics. 14 (4): 959-964.
3. Nicoloso M, Qu LH, Michot B, Bachellerie JP (1996). "Intron-encoded, antisense small nucleolar RNAs: the characterization of nine novel species points to their direct role as guides for the 2'-O-ribose methylation of rRNAs". J. Mol. Biol. 260 (2): 178-195.

Other Notes

Small volumes of anti-RPL13A antibody vial(s) may occasionally become entrapped in the seal of the product vial during shipment and storage. If necessary, briefly centrifuge the vial on a tabletop centrifuge to dislodge any liquid in the container`s cap. Certain products may require to ship with dry ice and additional dry ice fee may apply.

Searchable Terms for RPL13A purchase

MBS1754023 is an antibody targeting RPL13A. Also known as Anti-RPL13A Antibody (monoclonal, 4C9). Reactive in Human. Host: Mouse.

Additional Details

NCBI/Uniprot data below describe general gene information for RPL13A. It may not necessarily be applicable to this product.

NCBI GI #
NCBI GeneID
NCBI Accession #
UniProt Primary Accession #
UniProt Secondary Accession #
UniProt Related Accession #
GenBank Nucleotide #
NCBI Official Full Name
60S ribosomal protein L13a isoform 1
NCBI Official Synonym Full Names
ribosomal protein L13a
NCBI Official Symbol
RPL13A
NCBI Official Synonym Symbols
L13A; TSTA1
UniProt Protein Name
60S ribosomal protein L13a
UniProt Synonym Protein Names
23 kDa highly basic protein
Protein Family
UniProt Gene Name
RPL13A
UniProt Entry Name
RL13A_HUMAN
NCBI Protein Information
60S ribosomal protein L13a; 23 kDa highly basic protein; tissue specific transplantation antigen 1

Precautions

All of MyBioSource's Products are for scientific laboratory research purposes and are not for diagnostic, therapeutics, prophylactic or in vivo use. Through your purchase, you expressly represent and warrant to MyBioSource that you will properly test and use any Products purchased from MyBioSource in accordance with industry standards. MyBioSource and its authorized distributors reserve the right to refuse to process any order where we reasonably believe that the intended use will fall outside of our acceptable guidelines.

Disclaimer

While every efforts were made to ensure the accuracy of the information provided in this datasheet, MyBioSource will not be liable for any omissions or errors contained herein. MyBioSource reserves the right to make changes to this datasheet at any time without prior notice.

It is the responsibility of the customer to report product performance issues to MyBioSource within 30 days of receipt of the product. Please visit our Terms & Conditions page for more information.

Product Note

Select online data sheet information is drawn from bioinformatics databases, occasionally resulting in ambiguous or non-relevant product information. It is the responsibility of the customer to review, verify, and evaluate the information to make sure it matches their requirements before purchasing the kit. Our ELISA Kit assays are dynamic research tools and sometimes they may be updated and improved. If the format of this assay is important to you then please request the current manual or contact our technical support team with a presales inquiry before placing an order. We will confirm the current details of the assay. We cannot guarantee the sample manual posted online is the most current manual, it is intended to serve as an example only. Please refer to the instructions For Use provided with the assay kit for precise details.

Product PubMed Publications

Request a Quote

Please fill out the form below and our representative will get back to you shortly.

MBS000000
Contact Us

Please fill out the form below and our representative will get back to you shortly.

MBS000000