• Call +1.858.633.0165 or Fax +1.858.633.0166 or Contact Us

Phospholipase A2, Calcium Independent (iPLA2) Antibody – Rabbit Polyclonal

For Research Use Only. Not for use in diagnostic procedures. Special Promotion Catalog #: MBS2013823
SPECIAL PROMOTION: Get FREE $5 Starbucks gift card (Maximum 5 gift cards/product). Gift card(s) will be included with shipment

MBS2013823 is an antibody targeting iPLA2. Also known as Polyclonal Antibody to Phospholipase A2, Calcium Independent (iPLA2). Reactive in Rat, Human, Mouse. Host: Rabbit. More details

$210 / 0.1 mL +1 FREE 8GB USB
Product Documentation
PDF
Sample Manual Insert View PDF
PDF
Testing Data View PDF
PDF
Certificate of Analysis (COA) View PDF
PDF
QC Report View PDF
PDF
Material Safety Data Sheet View PDF
PDF
Technical Datasheet View PDF
PDF
Protocol View PDF

Product Overview

Online Datasheet in PDF
Product Name
Phospholipase A2, Calcium Independent (iPLA2), Polyclonal Antibody
Full Product Name
Polyclonal Antibody to Phospholipase A2, Calcium Independent (iPLA2)
Product Gene Name
Immunogen Sequence
Antigen: The target protein is fused with two N-terminal Tags, His-tag and T7-tag and its sequence is listed below.
MGSSHHHHHH SSGLVPRGSH MASMTGGQQM GRGSEF- LLCLDGGGVK GLVIIQLLIA IEKASGVATK DLFDWVAGTS TGGILALAIL HSKSMAYMRG VYFRMKDEVF RGSRPYESGP LEEFLKREFG EHTKMTDVKK PKVMLTGTLS DRQPAELHLF RNYDAPEAVR EPRCTPNINL KPPTQPADQL VWRAARSSGA APTYFRPNGR FLDGGLLANN PTLDAMTEIH EYNQDMIRKG
Clonality
Polyclonal
Host
Rabbit
Species Reactivity
Rat, Human, Mouse
Form/Format
Supplied as solution form in PBS, pH7.4, containing 0.02% NaN3,50% glycerol.
Purity/Purification
Affinity Chromatography
Concentration
500ug/mL (lot specific)
Specificity
The antibody is a rabbit polyclonal antibody raised against iPLA2. It has been selected for its ability to recognize iPLA2 in immunohistochemical staining andwestern blotting.
Preparation and Storage
Store at 4 degree C for frequent use. Stored at -20 degree C to -80 degree C in a manual defrost freezer for one year without detectable loss of activity. Avoid repeated freeze-thaw cycles.
Matching Pairs
Unconjugated Antibody: iPLA2 (MBS2013823)
Immunogen: iPLA2 (MBS2018374)
Matching Pairs
Unconjugated Antibody: iPLA2 (MBS2013823)
APC-CY7 Conjugated Antibody: iPLA2 (MBS2042063)
Molecular Weight
83,562 Da
3D Structure
ModBase 3D Structure for P97570
Supply Chain Verification
Manufactured in a lab with traceable raw materials. Bulk orders can typically be prepared to the customer’s specifications, please inquire.
Immunogen
Recombinant iPLA2 (Leu481~Val702) expressed in E.coli.
Cross Reactivity
Rat
Conjugated Antibody
The APC conjugated antibody version of this item is also available as catalog #MBS2042065
ISO Certification
Manufactured in an ISO 9001:2015 and ISO 13485:2016 Certified Laboratory.
Applications Tested/Suitable for anti-iPLA2 antibody
Immunocytochemistry (ICC), Immunohistochemistry (IHC) - Formalin/Paraffin, ELISA (EIA), Western Blot (WB)
Application Notes for anti-iPLA2 antibody
Western blotting: 1:100-400
Immunocytochemistry in formalin fixed cells: 1:100-500
Immunohistochemistry in formalin fixed frozen section: 1:100-500
Immunohistochemistry in paraffin section: 1:50-200
Enzyme-linked Immunosorbent Assay: 1:100-200

Western Blot (WB) of anti-iPLA2 antibody

Western Blot: Sample: Recombinant protein.
Rabbit Anti-iPLA2 Polyclonal Antibody – Cat# MBS2013823

Immunohistochemistry (IHC) of anti-iPLA2 antibody

DAB staining on fromalin fixed paraffin-embedded Liver tissue)
Rabbit Anti-iPLA2 Polyclonal Antibody, Immunohistochemistry (IHC) – Cat# MBS2013823

Other Notes

Small volumes of anti-iPLA2 antibody vial(s) may occasionally become entrapped in the seal of the product vial during shipment and storage. If necessary, briefly centrifuge the vial on a tabletop centrifuge to dislodge any liquid in the container`s cap. Certain products may require to ship with dry ice and additional dry ice fee may apply.

Additional Details

NCBI/Uniprot data below describe general gene information for iPLA2. It may not necessarily be applicable to this product.

NCBI GI #
NCBI GeneID
NCBI Accession #
UniProt Primary Accession #
UniProt Secondary Accession #
UniProt Related Accession #
GenBank Nucleotide #
NCBI Official Full Name
85/88 kDa calcium-independent phospholipase A2 isoform 1
NCBI Official Synonym Full Names
phospholipase A2 group VI
NCBI Official Symbol
Pla2g6
NCBI Official Synonym Symbols
iPla2; PNPLA9
UniProt Protein Name
85/88 kDa calcium-independent phospholipase A2
UniProt Synonym Protein Names
Group VI phospholipase A2; GVI PLA2; Intracellular membrane-associated calcium-independent phospholipase A2 beta; iPLA2-beta; Patatin-like phospholipase domain-containing protein 9; PNPLA9
UniProt Gene Name
Pla2g6
UniProt Synonym Gene Names
Pnpla9; CaI-PLA2; GVI PLA2; iPLA2-beta; PNPLA9
NCBI Protein Information
85/88 kDa calcium-independent phospholipase A2

NCBI Summary for iPLA2

has Ca2+ independent phospholipase A2 activity; may play a role in regulating transmembrane ionic fluxes in pancreatic beta cells [RGD, Feb 2006]

UniProt Comments for iPLA2

PLA2G6: Catalyzes the release of fatty acids from phospholipids. It has been implicated in normal phospholipid remodeling, nitric oxide-induced or vasopressin-induced arachidonic acid release and in leukotriene and prostaglandin production. May participate in fas mediated apoptosis and in regulating transmembrane ion flux in glucose-stimulated B-cells. Has a role in cardiolipin (CL) deacylation. Required for both speed and directionality of monocyte MCP1/CCL2-induced chemotaxis through regulation of F- actin polymerization at the pseudopods. Defects in PLA2G6 are the cause of neurodegeneration with brain iron accumulation type 2B (NBIA2B). A neurodegenerative disorder associated with iron accumulation in the brain, primarily in the basal ganglia. It is characterized by progressive extrapyramidal dysfunction leading to rigidity, dystonia, dysarthria and sensorimotor impairment. Defects in PLA2G6 are the cause of neurodegeneration with brain iron accumulation type 2A (NBIA2A); also known as Seitelberger disease. NBIA2A is a neurodegenerative disease characterized by pathologic axonal swelling and spheroid bodies in the central nervous system. Onset is within the first 2 years of life with death by age 10 years. Defects in PLA2G6 are the cause of Parkinson disease type 14 (PARK14). An adult-onset progressive neurodegenerative disorder characterized by parkinsonism, dystonia, severe cognitive decline, cerebral and cerebellar atrophy and absent iron in the basal ganglia on magnetic resonance imaging. 4 isoforms of the human protein are produced by alternative splicing.

Protein type: EC 3.1.1.4; Lipid Metabolism - alpha-linolenic acid; Lipid Metabolism - arachidonic acid; Lipid Metabolism - ether lipid; Lipid Metabolism - glycerophospholipid; Lipid Metabolism - linoleic acid; Phospholipase

Chromosomal Location of Human Ortholog: 7q34

Cellular Component: cytosol; extracellular space; microtubule organizing center; mitochondrial inner membrane; mitochondrion

Molecular Function: ATP-dependent protein binding; calcium-independent phospholipase A2 activity; calmodulin binding; phospholipase A2 activity; protein kinase binding; serine hydrolase activity

Biological Process: antibacterial humoral response; cardiolipin biosynthetic process; chemotaxis; elevation of cytosolic calcium ion concentration; lipid catabolic process; maternal process involved in female pregnancy; memory; negative regulation of synaptic transmission, glutamatergic; positive regulation of exocytosis; positive regulation of protein phosphorylation; urinary bladder smooth muscle contraction
Show more

Precautions

All of MyBioSource's Products are for scientific laboratory research purposes and are not for diagnostic, therapeutics, prophylactic or in vivo use. Through your purchase, you expressly represent and warrant to MyBioSource that you will properly test and use any Products purchased from MyBioSource in accordance with industry standards. MyBioSource and its authorized distributors reserve the right to refuse to process any order where we reasonably believe that the intended use will fall outside of our acceptable guidelines.

Disclaimer

While every efforts were made to ensure the accuracy of the information provided in this datasheet, MyBioSource will not be liable for any omissions or errors contained herein. MyBioSource reserves the right to make changes to this datasheet at any time without prior notice.

It is the responsibility of the customer to report product performance issues to MyBioSource within 30 days of receipt of the product. Please visit our Terms & Conditions page for more information.

Product Note

Select online data sheet information is drawn from bioinformatics databases, occasionally resulting in ambiguous or non-relevant product information. It is the responsibility of the customer to review, verify, and evaluate the information to make sure it matches their requirements before purchasing the kit. Our ELISA Kit assays are dynamic research tools and sometimes they may be updated and improved. If the format of this assay is important to you then please request the current manual or contact our technical support team with a presales inquiry before placing an order. We will confirm the current details of the assay. We cannot guarantee the sample manual posted online is the most current manual, it is intended to serve as an example only. Please refer to the instructions For Use provided with the assay kit for precise details.

Product PubMed Publications

Request a Quote

Please fill out the form below and our representative will get back to you shortly.

MBS000000
Contact Us

Please fill out the form below and our representative will get back to you shortly.

MBS000000