• Call +1.858.633.0165 or Fax +1.858.633.0166 or Contact Us

RAT Isotyping KIT (RAT) Assay Kit

For Research Use Only. Not for use in diagnostic procedures. Catalog #: MBS239187

Description: The rat monoclonal antibody isotyping test kit shows no cross-reactivity with bovine IgG (Test Principle: The assay principle is based on mouse polyclonal anti-rat antibodies coupled onto coloured micro particles and equally reactive to any rat… More details

DISCONTINUED
Click here to view our similar product(s) OR click here to contact our technical support team for suitable replacement.

Product Documentation

PDF
Sample Manual Insert View PDF
PDF
Testing Data View PDF
PDF
Certificate of Analysis (COA) View PDF
PDF
QC Report View PDF
PDF
Material Safety Data Sheet View PDF
PDF
Technical Datasheet View PDF
PDF
Protocol View PDF

Product Overview

Product Name
RAT ISOTYPING KIT, Assay Kit
Full Product Name
RAT MONOCLONAL ANTIBODY ISOTYPING TEST KIT
Form/Format
Kit
Preparation and Storage
Store at 4 degree C. DO NOT FREEZE. Do not use components from different lots.
Shelf Life: 12 months from date of despatch.
Technical Advice
PROBLEM
No heavy and or light-chain band appeared on the strip, but the positive flow control bands appeared.

Possible causes:
1. The antibody concentration was too low - prepare a less dilute sample and re-test.

2. No antibody was in the sample - the hybridoma is either not secreting or is not a rat monoclonal. If possible sub-clone the hybridoma and re-test.

3. Freshly diluted samples were not used - prepare fresh dilutions and re-test.

PROBLEM
Multiple heavy and light-chain bands appear on the strip.

Possible causes:
1. Antibody concentration was too high - dilute sample further and re-test.

2. For ascites, there may be small amounts of contaminating antibodies produced - dilute sample further and re-test.

3. For tissue culture supernatant, a mixed culture may be present - re-clone the hybridoma and re-test.

PROBLEM
No positive flow control bands appear.

Possible causes:

1. Sample volume was too low <150ul) - carefully dilute a fresh sample and pipette 150ul into a new development tube and re-test.

2. Strip removed from development tube too early - re-test and allow strip to react for at least 10 minutes.
Reagents In The Kits
1 Desiccant vial containing rat isotyping test strips, 10 tests.
10 Capped ready-to-use lyophilized microparticle development tubes.
Instructions For Use||Note: All reagents should be brought to room temperature before use.
Sample Preparation:
Dilute all monoclonal antibody samples to a concentration of 1.0 ug/ml in PBS containing 1% w/v bovine serum albumin (BSA). If the concentration of the sample is entirely unknown, make dilutions based on the following estimates:
Typically, serum contains between 10-15 mg/ml IgG and ascites can be as high as 10 mg/ml. Hollow fibre bioreactor culture supernatants contain approximately 0.5-1.0 mg/ml, whereas static flask tissue culture supernatants usually contain 10-50 ug/ml. Using these estimates, the appropriate dilutions can be made.
150ul of the diluted sample will be added to the development tubes.
Assay Protocol:
1. Remove the required number of isotyping strips from the desiccant vial and replace thecap. Remove the caps from an equal number of development tubes.
Note: the tubes may be labeled with a marker for identification.
2. Pipette 150ul of the freshly diluted sample into each development tube and incubate at room temperature for 30 seconds. Vortex the tube briefly to ensure that the coloured micro particle solution is completely re-suspended.
3. Place one isotyping strip, with the solid red end at the bottom, into each development tube.
Interpretation of Results:
Interpret the results at 5-10 minutes once the positive flow control bands have appeared. Within 5-10 minutes, a blue band will appear above the letters in one of the class or subclass windows as well as in the kappa window of the strip, indicating the heavy and light-chain composition of the monoclonal antibody (lambda light chains are very rare in rat monoclonal antibodies, but if present no positive band will be seen in the kappa window). The intensity of the blue bands will increase as the sample continues to flow up the strip. The positive flow control bands on one side of the isotyping test strip should also appear, indicating that the antibody-coated micro particles are functional and have flowed up the strip. In cases where the sample is very dilute, the development time may take up to 10 minutes.
Note: For a permanent experimental record or for an easier interpretation of results when testing multiple samples, the solid red area may be cut off the bottom of the strip to prevent further band development once the positive flow control bands have appeared. A gentle stream of air can be applied to the membrane portion of the strip to assist in drying the membrane and preventing any further development. Do not wash the strip to stop the reaction.
Target Species
Rat
Applications Tested/Suitable for RAT ISOTYPING KIT assay kit
Isotyping Assay (IS)

Testing Data #1 of RAT ISOTYPING KIT assay kit

For a permanent experimental record or for an easier interpretation of results when testing multiple samples, the solid red area may be cut off the bottom of the strip to prevent further band development once the positive flow control bands have appeared. A gentle stream of air can be applied to the membrane portion of the strip to assist in drying the membrane and preventing any further development. Do not wash the strip to stop the reaction.
RAT Assay Kit – Cat# MBS239187

Testing Data #2 of RAT ISOTYPING KIT assay kit

Rat isotyping test kits (MBS239187) contain simple dipstick test strips that give accurate results in less than 10 minutes. They have a high sensitivity during very early culture and all major classes and subclasses of immunoglobulin are discernable
RAT Assay Kit, Testing Data #2 – Cat# MBS239187

Other Notes

Small volumes of RAT ISOTYPING KIT assay kit vial(s) may occasionally become entrapped in the seal of the product vial during shipment and storage. If necessary, briefly centrifuge the vial on a tabletop centrifuge to dislodge any liquid in the container`s cap. Certain products may require to ship with dry ice and additional dry ice fee may apply.

Searchable Terms for RAT ISOTYPING KIT purchase

MBS239187 is an assay kit targeting RAT ISOTYPING KIT. Also known as RAT MONOCLONAL ANTIBODY ISOTYPING TEST KIT.
Request a Quote

Please fill out the form below and our representative will get back to you shortly.

MBS000000
Contact Us

Please fill out the form below and our representative will get back to you shortly.

MBS000000