• Call +1.858.633.0165 or Fax +1.858.633.0166 or Contact Us

Col-F Collagen Binding Reagent – Cellular Imaging

For Research Use Only. Not for use in diagnostic procedures. Catalog #: MBS258089

Collagens and elastins are primarily synthesized by fibroblasts. These molecules are principal components of extracellular matrices. Once outside the cell, collagen assembles into fibrils and fibers that provide mechanical strength to tissues. Elastin is… More details

DISCONTINUED
Click here to view our similar product(s) OR click here to contact our technical support team for suitable replacement.
Product Documentation
PDF
Sample Manual Insert View PDF
PDF
Testing Data View PDF
PDF
Certificate of Analysis (COA) View PDF
PDF
QC Report View PDF
PDF
Material Safety Data Sheet View PDF
PDF
Technical Datasheet View PDF
PDF
Protocol View PDF

Product Overview

Product Name
Col-F Collagen Binding Reagent
Full Product Name
Col-F Collagen Binding Reagent
Product Synonym Names
Collagen and Elastin
Preparation and Storage
Store at ≤ -20°C.
Avoid freeze/thaw cycles.
Applications Tested/Suitable for Col-F Collagen Binding Reagent reagent
Fluorescence Microscope
How to use:
Col-F is supplied as a lyophilized powder. Typical staining concen-trations range between 1-20 μM. However, the optimal staining concentration will vary for diff erent situations and therefore needs to be determined experimentally by the end user. The ideal staining time varies depending on application, and can range from 5-10 minutes to several hours. Optimal staining times or pe-riods will need to be determined experimentally by the user. ICT recommends staining for 30 minutes as a starting point. To stain collagen and elastin:

1. When ready to use, reconstitute the 0.5 mg Col-F vial by adding 100 uL DMSO (this creates a stock at 6.8 mM).
2. Optional: Incubate samples with blocking buffer for 60 minutes.
3. Add Col-F to the media/buffer for each appropriate sample.
4. Incubate the samples with the dye solutions for 5-60 minutes at 37°C.
5. Wash samples twice with PBS (allow samples to incubate at room temp for 5-10 minutes in PBS during each wash step)
6. Once wash steps are complete, mount a coverslip on each slide. Samples are now ready to visualize with a fluorescence microscope capable of excitation at 490 nm, and emission at 515-520 nm.

Microscopy Imaging of Col-F Collagen Binding Reagent reagent

FIGURE 1: MICROSCOPY IMAGING Fluorescence microscopy imaging of a frozen murine tissue section containing a blood vessel stained with 1 uM Col-F for 30 minutes. Collagen and elastin present in the blood vessel wall stained green. Nuclei were counter-stained blue with DAPI. Image was captured using a Nikon TiE Deconvolution Microscope. Data courtesy of Dr. Mike Olin, University of Minnesota.
Col-F Collagen Binding Reagent – Cat# MBS258089

Other Notes

Small volumes of Col-F Collagen Binding Reagent reagent vial(s) may occasionally become entrapped in the seal of the product vial during shipment and storage. If necessary, briefly centrifuge the vial on a tabletop centrifuge to dislodge any liquid in the container`s cap. Certain products may require to ship with dry ice and additional dry ice fee may apply.

Searchable Terms for Col-F Collagen Binding Reagent purchase

MBS258089 is a reagent targeting Col-F Collagen Binding Reagent.
Request a Quote

Please fill out the form below and our representative will get back to you shortly.

MBS000000
Contact Us

Please fill out the form below and our representative will get back to you shortly.

MBS000000