• Call +1.858.633.0165 or Fax +1.858.633.0166 or Contact Us

Immunoglobulin J Chain (IGJ) ELISA Kit for Mouse

For Research Use Only. Not for use in diagnostic procedures. Catalog #: MBS284130

Principle of the Assay: The microtiter plate provided in this kit has been pre-coated with Mouse IGJ. Samples are then added to the appropriate microtiter plate wells with a Horseradish Peroxidase (HRP)-conjugated antibody preparation specific for IGJ and… More details

$495 / 48 Tests +1 FREE 8GB USB

Product Documentation

PDF
Sample Manual Insert View PDF
PDF
Testing Data View PDF
PDF
Certificate of Analysis (COA) View PDF
PDF
QC Report View PDF
PDF
Material Safety Data Sheet View PDF
PDF
Technical Datasheet View PDF
PDF
Protocol View PDF

Product Overview

Online Datasheet in PDF
Product Name
Immunoglobulin J chain (IGJ), ELISA Kit
Full Product Name
Mouse Immunoglobulin J chain (IGJ) ELISA Kit
Product Gene Name
Product Synonym Names
IGCJ; JCH; immunoglobulin J chain
Species Reactivity
Mouse
Samples
Serum, plasma and other biological fluids
Detection Range
0.78 ng/mL - 50 ng/mL
Sensitivity
0.39 ng/mL (mean of 6 independent assays)
Specificity
This assay has high sensitivity and excellent specificity for detection of Mouse IGJ. No significant cross-reactivity or interference between Mouse IGJ and analogues was observed.
Preparation and Storage
Store at 2-8 degree C.
Inter-assay Precision
Inter-assay Precision (Precision between assays) Three samples of known concentration were tested in forty separate assays to assess inter-assay precision. CV(%) = SD/meanX100. Inter-Assay: CV<12%
Intra-assay Precision
Intra-assay Precision (Precision within an assay) Three samples of known concentration were tested twenty times on one plate to assess intra-assay precision. Intra-Assay: CV<10%
Molecular Weight
18,014 Da
3D Structure
ModBase 3D Structure for P01592
ISO Certification
Manufactured in an ISO 9001:2015 Certified Laboratory.

Other Notes

Small volumes of IGJ elisa kit vial(s) may occasionally become entrapped in the seal of the product vial during shipment and storage. If necessary, briefly centrifuge the vial on a tabletop centrifuge to dislodge any liquid in the container`s cap. Certain products may require to ship with dry ice and additional dry ice fee may apply.

Searchable Terms for IGJ purchase

MBS284130 is a ready-to-use microwell, strip-or-full plate ELISA (enzyme-linked immunosorbent assay) Kit for analyzing the presence of the Immunoglobulin J chain (IGJ) ELISA Kit target analytes in biological samples. The concentration gradients of the kit standards or positive controls render a theoretical kit detection range in biological research samples containing IGJ. The ELISA analytical biochemical technique of the MBS284130 kit is based on IGJ antibody-IGJ antigen interactions (immunosorbency) and an HRP colorimetric detection system to detect IGJ antigen targets in samples. The ELISA Kit is designed to detect native, not recombinant, IGJ. Appropriate sample types may include undiluted body fluids and/or tissue homogenates, secretions. Quality control assays assessing reproducibility identified the intra-assay CV (%) and inter-assay CV(%).

Additional Details

NCBI/Uniprot data below describe general gene information for IGJ. It may not necessarily be applicable to this product.

NCBI GI #
NCBI GeneID
NCBI Accession #
UniProt Primary Accession #
UniProt Related Accession #
GenBank Nucleotide #
NCBI Official Full Name
immunoglobulin J chain
NCBI Official Synonym Full Names
immunoglobulin joining chain
NCBI Official Symbol
Jchain
NCBI Official Synonym Symbols
Igj; Jch; AI323815; 9530090F24Rik
UniProt Protein Name
Immunoglobulin J chain
Protein Family
UniProt Gene Name
Jchain
NCBI Protein Information
immunoglobulin J chain

UniProt Comments for IGJ

IGJ: Serves to link two monomer units of either IgM or IgA. In the case of IgM, the J chain-joined dimer is a nucleating unit for the IgM pentamer, and in the case of IgA it induces larger polymers. It also help to bind these immunoglobulins to secretory component.

Protein type: Secreted; Secreted, signal peptide

Chromosomal Location of Human Ortholog: 5|5 E1

Cellular Component: extracellular region; extracellular space

Molecular Function: antigen binding; IgA binding; peptidoglycan binding; phosphatidylcholine binding; protein binding, bridging; protein homodimerization activity; single-stranded DNA binding

Biological Process: adaptive immune response; antibacterial humoral response; glomerular filtration; humoral immune response; innate immune response; positive regulation of protein oligomerization
Show more

Precautions

All of MyBioSource's Products are for scientific laboratory research purposes and are not for diagnostic, therapeutics, prophylactic or in vivo use. Through your purchase, you expressly represent and warrant to MyBioSource that you will properly test and use any Products purchased from MyBioSource in accordance with industry standards. MyBioSource and its authorized distributors reserve the right to refuse to process any order where we reasonably believe that the intended use will fall outside of our acceptable guidelines.

Disclaimer

While every efforts were made to ensure the accuracy of the information provided in this datasheet, MyBioSource will not be liable for any omissions or errors contained herein. MyBioSource reserves the right to make changes to this datasheet at any time without prior notice.

It is the responsibility of the customer to report product performance issues to MyBioSource within 30 days of receipt of the product. Please visit our Terms & Conditions page for more information.

Product Note

Select online data sheet information is drawn from bioinformatics databases, occasionally resulting in ambiguous or non-relevant product information. It is the responsibility of the customer to review, verify, and evaluate the information to make sure it matches their requirements before purchasing the kit. Our ELISA Kit assays are dynamic research tools and sometimes they may be updated and improved. If the format of this assay is important to you then please request the current manual or contact our technical support team with a presales inquiry before placing an order. We will confirm the current details of the assay. We cannot guarantee the sample manual posted online is the most current manual, it is intended to serve as an example only. Please refer to the instructions For Use provided with the assay kit for precise details.

Product PubMed Publications

Request a Quote

Please fill out the form below and our representative will get back to you shortly.

MBS000000
Contact Us

Please fill out the form below and our representative will get back to you shortly.

MBS000000