• Call +1.858.633.0165 or Fax +1.858.633.0166 or Contact Us

Trypsinogen (USO1) ELISA Kit for Human

For Research Use Only. Not for use in diagnostic procedures. Catalog #: MBS285780

Principle of the Assay: This assay employs a two-site sandwich ELISA to quantitate USO1 in samples. An antibody specific for USO1 has been pre-coated onto a microplate. Standards and samples are pipetted into the wells and anyUSO1 present is bound by the… More details

$545 / 48 Tests +1 FREE 8GB USB

Product Documentation

PDF
Sample Manual Insert View PDF
PDF
Testing Data View PDF
PDF
Certificate of Analysis (COA) View PDF
PDF
QC Report View PDF
PDF
Material Safety Data Sheet View PDF
PDF
Technical Datasheet View PDF
PDF
Protocol View PDF

Product Overview

Online Datasheet in PDF
Product Name
Trypsinogen (USO1), ELISA Kit
Full Product Name
Human Trypsinogen activation peptide (TAP) ELISA Kit
Product Gene Name
Product Synonym Names
P115; TAP; VDP; USO1 homolog; vesicle docking protein|transcytosis associated protein|vesicle docking protein p115
Species Reactivity
Human
Assay Type
Sandwich
Samples
Serum, Plasma, Other biological fluids
Specificity
This assay has high sensitivity and excellent specificity for detection of Human USO1. No significant cross-reactivity or interference between Human USO1 and analogues was observed.
Preparation and Storage
Store at 2-8 degree C.
Molecular Weight
109,195 Da
OMIM
D86326 mRNA
3D Structure
ModBase 3D Structure for O60763
Sample Volume
1-200 uL
Precision
Intra-assay Precision (Precision within an assay)
Three samples of known concentration were tested twenty times on one plate to assess intra-assay precision.
Inter-assay Precision (Precision between assays)
Three samples of known concentration were tested in forty separate assays to assess inter-assay precision.
CV (%) = SD/meanX100
Intra-Assay: CV
Inter-Assay: CV
Detection Wavelength
450 nm
ISO Certification
Manufactured in an ISO 9001:2015 Certified Laboratory.

Other Notes

Small volumes of USO1 elisa kit vial(s) may occasionally become entrapped in the seal of the product vial during shipment and storage. If necessary, briefly centrifuge the vial on a tabletop centrifuge to dislodge any liquid in the container`s cap. Certain products may require to ship with dry ice and additional dry ice fee may apply.

Searchable Terms for USO1 purchase

MBS285780 is a ready-to-use microwell, strip-or-full plate ELISA (enzyme-linked immunosorbent assay) Kit for analyzing the presence of the Trypsinogen (USO1) ELISA Kit target analytes in biological samples. The concentration gradients of the kit standards or positive controls render a theoretical kit detection range in biological research samples containing USO1. The ELISA analytical biochemical technique of the MBS285780 kit is based on USO1 antibody-USO1 antigen interactions (immunosorbency) and an HRP colorimetric detection system to detect USO1 antigen targets in samples. The ELISA Kit is designed to detect native, not recombinant, USO1. Appropriate sample types may include undiluted body fluids and/or tissue homogenates, secretions. Quality control assays assessing reproducibility identified the intra-assay CV (%) and inter-assay CV(%).

Additional Details

NCBI/Uniprot data below describe general gene information for USO1. It may not necessarily be applicable to this product.

NCBI GI #
NCBI GeneID
NCBI Accession #
UniProt Primary Accession #
UniProt Secondary Accession #
UniProt Related Accession #
GenBank Nucleotide #
NCBI Official Full Name
general vesicular transport factor p115 isoform 1
NCBI Official Synonym Full Names
USO1 vesicle transport factor
NCBI Official Symbol
USO1
NCBI Official Synonym Symbols
TAP; VDP; P115
UniProt Protein Name
General vesicular transport factor p115
UniProt Synonym Protein Names
Protein USO1 homolog; Transcytosis-associated protein; TAP; Vesicle-docking protein
UniProt Gene Name
USO1
UniProt Synonym Gene Names
VDP; TAP
NCBI Protein Information
general vesicular transport factor p115

NCBI Summary for USO1

The protein encoded by this gene is a peripheral membrane protein which recycles between the cytosol and the Golgi apparatus during interphase. It is regulated by phosphorylation: dephosphorylated protein associates with the Golgi membrane and dissociates from the membrane upon phosphorylation. Ras-associated protein 1 recruits this protein to coat protein complex II (COPII) vesicles during budding from the endoplasmic reticulum, where it interacts with a set of COPII vesicle-associated SNAREs to form a cis-SNARE complex that promotes targeting to the Golgi apparatus. Alternative splicing results in multiple transcript variants. [provided by RefSeq, Feb 2014]
Show more

UniProt Comments for USO1

TAP: General vesicular transport factor required for intercisternal transport in the Golgi stack; it is required for transcytotic fusion and/or subsequent binding of the vesicles to the target membrane. May well act as a vesicular anchor by interacting with the target membrane and holding the vesicular and target membranes in proximity. Belongs to the VDP/USO1/EDE1 family. 2 isoforms of the human protein are produced by alternative splicing.

Protein type: Motility/polarity/chemotaxis; Vesicle

Chromosomal Location of Human Ortholog: 4q21.1

Cellular Component: cytosol; endoplasmic reticulum; ER to Golgi transport vesicle membrane; fibrillar center; Golgi apparatus; Golgi membrane; Golgi stack; membrane; perinuclear region of cytoplasm; transport vesicle

Molecular Function: cadherin binding; protein binding; protein transporter activity; RNA binding

Biological Process: COPII vesicle coating; ER to Golgi vesicle-mediated transport; Golgi organization and biogenesis; Golgi vesicle docking; intracellular protein transport; transcytosis; vesicle fusion with Golgi apparatus
Show more

Precautions

All of MyBioSource's Products are for scientific laboratory research purposes and are not for diagnostic, therapeutics, prophylactic or in vivo use. Through your purchase, you expressly represent and warrant to MyBioSource that you will properly test and use any Products purchased from MyBioSource in accordance with industry standards. MyBioSource and its authorized distributors reserve the right to refuse to process any order where we reasonably believe that the intended use will fall outside of our acceptable guidelines.

Disclaimer

While every efforts were made to ensure the accuracy of the information provided in this datasheet, MyBioSource will not be liable for any omissions or errors contained herein. MyBioSource reserves the right to make changes to this datasheet at any time without prior notice.

It is the responsibility of the customer to report product performance issues to MyBioSource within 30 days of receipt of the product. Please visit our Terms & Conditions page for more information.

Product Note

Select online data sheet information is drawn from bioinformatics databases, occasionally resulting in ambiguous or non-relevant product information. It is the responsibility of the customer to review, verify, and evaluate the information to make sure it matches their requirements before purchasing the kit. Our ELISA Kit assays are dynamic research tools and sometimes they may be updated and improved. If the format of this assay is important to you then please request the current manual or contact our technical support team with a presales inquiry before placing an order. We will confirm the current details of the assay. We cannot guarantee the sample manual posted online is the most current manual, it is intended to serve as an example only. Please refer to the instructions For Use provided with the assay kit for precise details.

Product PubMed Publications

Products associated with USO1 elisa kit

 Reference Product  PubMed Publications
 GORASP1 elisa kit  >1 publications with USO1 and GORASP1
Request a Quote

Please fill out the form below and our representative will get back to you shortly.

MBS000000
Contact Us

Please fill out the form below and our representative will get back to you shortly.

MBS000000