• Call +1.858.633.0165 or Fax +1.858.633.0166 or Contact Us

Lipoprotein, Low Density (LDL) Receptor Antibody – Mouse Monoclonal

For Research Use Only. Not for use in diagnostic procedures. Catalog #: MBS310928

MBS310928 is an antibody targeting Lipoprotein, Low Density (LDL) Receptor. Also known as MAb to LDL Receptor. Reactive in Human, Bovine. Host: Mouse. More details

DISCONTINUED
Click here to view our similar product(s) OR click here to contact our technical support team for suitable replacement.
Product Documentation
PDF
Sample Manual Insert View PDF
PDF
Testing Data View PDF
PDF
Certificate of Analysis (COA) View PDF
PDF
QC Report View PDF
PDF
Material Safety Data Sheet View PDF
PDF
Technical Datasheet View PDF
PDF
Protocol View PDF

Product Overview

Product Name
Lipoprotein, Low Density (LDL) Receptor, Monoclonal Antibody
Full Product Name
MAb to LDL Receptor
Product Synonym Names
Monoclonal Antibody to Human/Bovine Low Density Lipoprotein (LDL) Receptor
Clonality
Monoclonal
Isotype
IgG2b, kappa
Host
Mouse
Species Reactivity
Human, Bovine
Form/Format
Purified, Lyophilized
Reconstitute with 1ml distilled water.
Concentration
50ug/ml (prior to lyophilization) (lot specific)
Specificity
Lipoprotein, Low Density (LDL) Receptor
Recognizes an epitope in the region of repeat #1 of the ligand binding region. Addition of 15nM antibody results in inhibition of half-maximal LDL-binding.(1) Recognizes human and cow. Does not react with rat, mo
Preparation and Storage
Store lyophilized product at 2 to 8 degree C. After reconstitution, product is stable for up to one year when stored at 2 to 8 degree C when a preservative (e.g. Thimerosal) has been added. Prepare working dilution only prior to immediate use.
Immunogen
Purified bovine adrenal cortex LDL receptor
Affinity Constant
Not determined
Buffer
Lyophilized from PBS, pH 7.4 containing 0.5% BSA
Preservative
No
Lyophilized
Yes
Important Note
Centrifuge before opening to ensure complete recovery of vial contents.
ISO Certification
Manufactured in an ISO 13485:2003 and EN ISO 13485:2012 Certified Laboratory.
Flow Cytometry, Immunofluorescence Assay, Western Blot

Product References and Citations for anti-Lipoprotein, Low Density (LDL) Receptor antibody

• Beisiegel, U., et al., (1981), "Monoclonal antibodies to the low density lipoprotein receptor as probes for study of receptor-mediated endocytosis and the genetics of familial hypercholesterolemia", J. Biol. Chem., 256, 11923-11931.
•&

Other Notes

Small volumes of anti-Lipoprotein, Low Density (LDL) Receptor antibody vial(s) may occasionally become entrapped in the seal of the product vial during shipment and storage. If necessary, briefly centrifuge the vial on a tabletop centrifuge to dislodge any liquid in the container`s cap. Certain products may require to ship with dry ice and additional dry ice fee may apply.

Additional Details

NCBI/Uniprot data below describe general gene information for Lipoprotein, Low Density (LDL) Receptor. It may not necessarily be applicable to this product.

NCBI GI #
NCBI Accession #
GenBank Nucleotide #
NCBI Official Full Name
lipoprotein

Precautions

All of MyBioSource's Products are for scientific laboratory research purposes and are not for diagnostic, therapeutics, prophylactic or in vivo use. Through your purchase, you expressly represent and warrant to MyBioSource that you will properly test and use any Products purchased from MyBioSource in accordance with industry standards. MyBioSource and its authorized distributors reserve the right to refuse to process any order where we reasonably believe that the intended use will fall outside of our acceptable guidelines.

Disclaimer

While every efforts were made to ensure the accuracy of the information provided in this datasheet, MyBioSource will not be liable for any omissions or errors contained herein. MyBioSource reserves the right to make changes to this datasheet at any time without prior notice.

It is the responsibility of the customer to report product performance issues to MyBioSource within 30 days of receipt of the product. Please visit our Terms & Conditions page for more information.

Product Note

Select online data sheet information is drawn from bioinformatics databases, occasionally resulting in ambiguous or non-relevant product information. It is the responsibility of the customer to review, verify, and evaluate the information to make sure it matches their requirements before purchasing the kit. Our ELISA Kit assays are dynamic research tools and sometimes they may be updated and improved. If the format of this assay is important to you then please request the current manual or contact our technical support team with a presales inquiry before placing an order. We will confirm the current details of the assay. We cannot guarantee the sample manual posted online is the most current manual, it is intended to serve as an example only. Please refer to the instructions For Use provided with the assay kit for precise details.

Product PubMed Publications

Products associated with anti-Lipoprotein, Low Density (LDL) Receptor antibody

Request a Quote

Please fill out the form below and our representative will get back to you shortly.

MBS000000
Contact Us

Please fill out the form below and our representative will get back to you shortly.

MBS000000