SV-40 Slide

For Research Use Only. Not for use in diagnostic procedures. Catalog #: MBS373156

SV40 is an abbreviation for Simian vacuolating virus 40 or Simian virus 40, a polyomavirus that is found in both monkeys and humans. Like other polyomaviruses, SV40 is a DNA virus that has the potential to cause tumors, but most often persists as a latent… More details

Product Documentation
PDF
Sample Manual Insert View PDF
PDF
Testing Data View PDF
PDF
Certificate of Analysis (COA) View PDF
PDF
QC Report View PDF
PDF
Material Safety Data Sheet View PDF
PDF
Technical Datasheet View PDF
PDF
Protocol View PDF

Product Overview

Online Datasheet in PDF
Product Name
SV-40, Slide
Full Product Name
SV-40 Slide
Clonality
Monoclonal
Clone Number
Intended to be used with clone Pab101.
Form/Format
Five slides of SV40 positive tissues, each mounted on Hydrophilic Plus Slides, provided in a plastic mailer.
Preparation and Storage
Store at 20-25°C
Precautions
1. This product contains <0.1% sodium azide (NaNl) as a preservative. Ensure proper handling procedures are used with this reagent.
2. Always wear personal protective equipment such as a Laboratory coat, goggles, and gloves when handling reagents.
3. Dispose of unused solution with copious amounts of water.
4. Do not ingest reagent. If reagent is ingested, seek medical advice immediately.
5. Avoid contact with eyes. If contact occurs, flush with large quantities of water.
6. Follow safety precautions of the heating device used for epitope retrieval (TintoRetriever Pressure Cooker or similar).
7. For additional safety information refer to Safety Data Sheet for this product.
8. For complete recommendations for handling biological specimens, please refer to the CDC document, "Guidelines for Safe Work Practices in Human and AMDL.
Mounting Protocols
For detailed instructions using biodegradable permanent mounting media such as XyGreen PermaMounter or organic solvent-based resin such as PermaMounter.
Product Limitations
Due to inherent variability present in immunohistochemical procedures (including fixation time of tissues, dilution factor of antibody, retrieval method utilized, and incubation time), optimal performance should be established through the use of positive and negative controls.
ISO Certification
Manufactured in an ISO 13485:2016 Certified Laboratory.
Application Notes for SV-40 slide
IHC Protocol:
1. Subject tissues to heat induced epitope retrieval (HIER) using a suitable retrieval solution such as ImmunoDNA Retriever with Citrateor EDTA.
2. Any of three heating methods may be used:

a. TintoRetriever Pressure Cooker or Equivalent Place tissues/slides in a staining dish or coplin jar containing the ImmunoDNA Retriever with Citrate or EDTA and place on trivet in the pressure cooker. Add 1-2 inches of distilled water to the pressure cooker and turn heat to high. Incubate for 15 minutes. Open and immediately transfer slides to room temperature.
b. TintoRetriever PT Module or Water Bath Method Place tissues/slides in a pre-warmed staining dish or coplin jar containing the ImmunoDNA Retriever with Citrate or EDTA at 95°-99° C. Incubate for 30-60 minutes.
c. Conventional Steamer Method Place tissues/slides in a pre-warmed staining dish or coplin jar containing the ImmunoDNA Retriever with Citrate or EDTA in a steamer, cover and steam for 30-60 minutes.

3. After heat treatment, transfer slides in ImmunoDNA Retriever with Citrate or EDTA to room temperature and let stand for 15-20 minutes.
4. For manual staining, perform antibody incubation at ambient temperature. For automated staining methods, perform antibody incubation according to instrument manufacturer’s instructions.
5. Wash slides with ImmunoDNA washer or DI water.
6. Continue IHC staining protocol. Wash slides between each step with ImmunoDNA washer solution.

Testing Data (TD) of SV-40 slide

SV-40 Slide – Cat# MBS373156

Testing Data (TD) of SV-40 slide

The map below outline formats of the 2 and 9-core disease arrays. Each slide comes with a "blank" core for easy orientation.
SV-40 Slide, Testing Data (TD) – Cat# MBS373156

Testing Data (TD) of SV-40 slide

SV-40 Slide, Testing Data (TD) – Cat# MBS373156

Other Notes

Small volumes of SV-40 slide vial(s) may occasionally become entrapped in the seal of the product vial during shipment and storage. If necessary, briefly centrifuge the vial on a tabletop centrifuge to dislodge any liquid in the container`s cap. Certain products may require to ship with dry ice and additional dry ice fee may apply.

Searchable Terms for SV-40 purchase

MBS373156 is a slide targeting SV-40.