• Call +1.858.633.0165 or Fax +1.858.633.0166 or Contact Us

Growth Hormone (Hgh)(somatropin) Pharmacokinetic (hGH) ELISA Kit for Human

For Research Use Only. Not for use in diagnostic procedures. Catalog #: MBS378419

Background: The GH ELISA kit contains the components required for measuring natural and recombinant human GH in biological matrices such as human serum, plasma or cell culture supernatant.Principle of the Assay: This assay employs the indirect sandwich enzyme… More details

$1120 / 1x96 Wells +1 FREE 8GB USB

Product Documentation

PDF
Sample Manual Insert View PDF
PDF
Testing Data View PDF
PDF
Certificate of Analysis (COA) View PDF
PDF
QC Report View PDF
PDF
Material Safety Data Sheet View PDF
PDF
Technical Datasheet View PDF
PDF
Protocol View PDF

Product Overview

Online Datasheet in PDF
Product Name
growth hormone (hGH)(Somatropin) Pharmacokinetic, ELISA Kit
Full Product Name
Human growth hormone (hGH)(Somatropin) Pharmacokinetic ELISA
Product Gene Name
Product Synonym Names
human growth hormone
Species Reactivity
Human
Assay Type
Sandwich
Detection Range
93.75 pg/mL
Specificity
In presence of interfering materials, prolactin, IGF-I,IGF-II, M-CSF, GM-CSF, IGFRB-3 and IL-3RB, all levels of hGH met the acceptance criteria of having a percent error of ± 20% of concentrations of 3000 ng/mL, 1500 ng/mL, 750 ng/mL, 375 ng/mL and 187.5 ng/mL and a percent error of ± 25% of concentrations of 5000 ng/mL (ULOQ) and 93.75 ng/mL (LLOQ).
Preparation and Storage
Store at -20 degree C, 1 year
Assay Procedure
This assay employs the indirect sandwich enzyme immunoassay technique. Anti-GH is coated onto a 96 well microplate. Calibrator and test samples prepared by dilution into assay buffer and are pipetted into the appropriate wells. GH present in biological matrices is bound by the immobilized anti- GH antibody. After washing away any unbound substances, tagged antiGH secondary antibody is added to the wells. After washing, diluted detection reagent is added to the wells. The plate is washed to remove any unbound antibody-enzyme reagent and a substrate solution is added to the wells for color development. The color development is proportional to the amount of GH present in test samples. The color development is stopped and the intensity of the color is measured.
Reagent Preparation
Prepare only the appropriate amount of required reagent on the day of use. Store all reagents as per instructions stated on the label. 1. Wash Buffer (1X) Preparation: Dilute wash bufferconcentrate with ultra-pure water 1/20 before use(for example add 25mL concentrate to 475mL ultrapure water). Mix well.2. Secondary Antibody (1X) Preparation: Dilute secondaryantibody with assay buffer 1/1000 before use (forexample add 12ul to 12mL of assay buffer). Mix well.3. Detection Reagent (1X) Preparation: Dilute detectionreagent with assay buffer 1/1000 before use (forexample add 12ul concentrate to 12ml of assay buffer).Mix well.4. Calibrator Preparation: Dilute the calibrator from 1mg/mldown to 5ug/ml by pipetting 5uL of calibrator stock into995uL assay buffer. Label "Cal. Int." Mix well. Preparecalibrators with concentrations ranging from 500 ng/mlto 9.375 ng/ml. The following is an example calibratorcurve.
Results Calculation
1. Construct a standard curve by plotting the absorbance obtained from each standard against concentration. Use a 4 or 5 parameter curve fit. 2. The concentration of the unknowns can be back calculated directly from this standard curve using the absorbance value for each sample. 3. Any sample diluted more or less than the standard series will need additional data correction. For example, if the sample is diluted 1/50, then the concentration will be calculated by dividing by 2 due to the calibrators being 2 times more diluted. Similarly, if the sample is diluted 1/500, then the concentration will be calculated by multiplying by a correction factor of 5 due to the calibrators being 5 times more concentrated.
Sample Preparation
Dilute calibrators and test samples 1/50 with assay buffer (for example add 5uL of prepared calibrator or sample to 245uL of assay buffer). Mix well. Do not store diluted samples.
Sample Collection
This kit is compatible with EDTA-plasma, heparinplasma and serum samples. Samples can be stored at or below -20 degree C for up to 1 year.
Dry Ice Shipment
Extra charge fee may add to your shipping cost as dry ice is required to ship this product.

Other Notes

Small volumes of hGH elisa kit vial(s) may occasionally become entrapped in the seal of the product vial during shipment and storage. If necessary, briefly centrifuge the vial on a tabletop centrifuge to dislodge any liquid in the container`s cap. Certain products may require to ship with dry ice and additional dry ice fee may apply.

Searchable Terms for hGH purchase

MBS378419 is a ready-to-use microwell, strip-or-full plate ELISA (enzyme-linked immunosorbent assay) Kit for analyzing the presence of the growth hormone (hGH)(Somatropin) Pharmacokinetic, ELISA Kit target analytes in biological samples. The concentration gradients of the kit standards or positive controls render a theoretical kit detection range in biological research samples containing hGH. The ELISA analytical biochemical technique of the MBS378419 kit is based on hGH antibody-hGH antigen interactions (immunosorbency) and an HRP colorimetric detection system to detect hGH antigen targets in samples. The ELISA Kit is designed to detect native, not recombinant, hGH. Appropriate sample types may include undiluted body fluids and/or tissue homogenates, secretions. Quality control assays assessing reproducibility identified the intra-assay CV (%) and inter-assay CV(%).

Additional Details

NCBI/Uniprot data below describe general gene information for hGH. It may not necessarily be applicable to this product.

NCBI GeneID

Precautions

All of MyBioSource's Products are for scientific laboratory research purposes and are not for diagnostic, therapeutics, prophylactic or in vivo use. Through your purchase, you expressly represent and warrant to MyBioSource that you will properly test and use any Products purchased from MyBioSource in accordance with industry standards. MyBioSource and its authorized distributors reserve the right to refuse to process any order where we reasonably believe that the intended use will fall outside of our acceptable guidelines.

Disclaimer

While every efforts were made to ensure the accuracy of the information provided in this datasheet, MyBioSource will not be liable for any omissions or errors contained herein. MyBioSource reserves the right to make changes to this datasheet at any time without prior notice.

It is the responsibility of the customer to report product performance issues to MyBioSource within 30 days of receipt of the product. Please visit our Terms & Conditions page for more information.

Product Note

Select online data sheet information is drawn from bioinformatics databases, occasionally resulting in ambiguous or non-relevant product information. It is the responsibility of the customer to review, verify, and evaluate the information to make sure it matches their requirements before purchasing the kit. Our ELISA Kit assays are dynamic research tools and sometimes they may be updated and improved. If the format of this assay is important to you then please request the current manual or contact our technical support team with a presales inquiry before placing an order. We will confirm the current details of the assay. We cannot guarantee the sample manual posted online is the most current manual, it is intended to serve as an example only. Please refer to the instructions For Use provided with the assay kit for precise details.
Request a Quote

Please fill out the form below and our representative will get back to you shortly.

MBS000000
Contact Us

Please fill out the form below and our representative will get back to you shortly.

MBS000000