• Call +1.858.633.0165 or Fax +1.858.633.0166 or Contact Us

CD163 Antibody – Mouse Monoclonal

For Research Use Only. Not for use in diagnostic procedures. Catalog #: MBS4380519

MBS4380519 is an antibody targeting CD163. Also known as CD163 (Monocyte & Macrophage Marker). Reactive in Human. Others not known.. Host: Mouse. More details

$280 / 0.02 mg (With BSA & Azide at 0.2mg/mL) +1 FREE 8GB USB
Product Documentation
PDF
Sample Manual Insert View PDF
PDF
Testing Data View PDF
PDF
Certificate of Analysis (COA) View PDF
PDF
QC Report View PDF
PDF
Material Safety Data Sheet View PDF
PDF
Technical Datasheet View PDF
PDF
Protocol View PDF

Product Overview

Online Datasheet in PDF
Product Name
CD163, Monoclonal Antibody
Full Product Name
CD163 (Monocyte & Macrophage Marker)
Product Gene Name
Product Synonym Names
CD163, CD163 antigen, Macrophage-associated antigen, M130, CD163 molecule, Hemoglobin scavenger receptor, MM130; Scavenger receptor cysteine rich type 1 protein M130
Clonality
Monoclonal
Isotype
IgG2b, kappa
Clone Number
M130/1210
Host
Mouse
Species Reactivity
Human. Others not known.
Form/Format
200ug/ml of Ab purified from Bioreactor Concentrate by Protein A/G. Prepared in 10mM PBS with 0.05% BSA & 0.05% azide.
Specificity
This MAb recognizes a protein of 140kDa, identified as CD163. It has been identified as an acute phase-regulated transmembrane protein whose function is to mediate the endocytosis of haptoglobin-hemoglobin complexes. This receptor is expressed on the surface of monocytes with low expression and on tissue macrophages, histiocytes with high expression. Staining with anti-CD163 has been helpful to distinguish synovial macrophages from synovial intimal fibroblasts in rheumatoid arthritis, where its specificity for macrophages was found to be superior to that of anti-CD68. Increased levels of CD163 were also detected in patients with microbial infections and myelomonocytic leukemias. Anti-CD163 is of considerable value for selective identification of monocytes and macrophages at a certain stage of differentiation and is suitable for myelomonocytic or monocytic leukaemia and neoplasms of true histiocytic origin. CD163 is positive in skin (histiocytes), gut, Kupffer cells, a few alveolar macrophages, macrophages in the placenta, and in macrophages in inflamed tissues including tumor tissue.
Preparation and Storage
Antibody with azide - store at 2 to 8°C. Non-hazardous. No MSDS required.
Molecular Weight
140kDa
3D Structure
ModBase 3D Structure for Q86VB7
Immunogen
Recombinant human CD163 fragment (around aa 43-196) (Exact sequence is proprietary)
Cellular Localization
Cell Surface & Cytoplasmic
Hu-chromosome Location
12p13.3
Positive Control
hPBL Cells. Skin, Lung, Placenta or Histiocytoma.
Applications Tested/Suitable for anti-CD163 antibody
Immunohistochemistry (IHC) Formalin
Application Notes for anti-CD163 antibody
Western Blot (1-2ug/ml)
Immunohistochemistry (Formalin-fixed) (1-2ug/ml for 30 minutes at RT)
(Staining of formalin-fixed tissues is enhanced by heating tissue sections in 10mM Tris with 1mM EDTA, pH 9.0 for 45 min at 95°C followed by cooling at RT for 20 minutes)
Optimal dilution for a specific application should be determined.

Immunohistochemistry (IHC) of anti-CD163 antibody

Formalin-fixed, paraffin-embedded human Lymph Node stained with CD163 Mouse Monoclonal Antibody (M130/1210).
Mouse Anti-CD163 Monoclonal Antibody – Cat# MBS4380519

Immunohistochemistry (IHC) of anti-CD163 antibody

Formalin-fixed, paraffin-embedded human Histiocytoma stained with CD163 Mouse Monoclonal Antibody (M130/1210).
Mouse Anti-CD163 Monoclonal Antibody, Immunohistochemistry (IHC) – Cat# MBS4380519

SDS-Page of anti-CD163 antibody

SDS-PAGE Analysis Purified CD163 Mouse Monoclonal Antibody (M130/1210).Confirmation of Integrity and Purity of Antibody.
Mouse Anti-CD163 Monoclonal Antibody, SDS-Page – Cat# MBS4380519

Western Blot (WB) of anti-CD163 antibody

Western Blot Analysis of Spleen tissue lysate using CD163 Mouse Monoclonal Antibody (M130/1210).
Mouse Anti-CD163 Monoclonal Antibody, Western Blot (WB) – Cat# MBS4380519

Test Data of anti-CD163 antibody

Analysis of Protein Array containing more than 19,000 full-length human proteins using CD163 Mouse Monoclonal Antibody (M130/1210).

Z- and S- Score: The Z-score represents the strength of a signal that a monoclonal antibody (MAb) (in combination with a fluorescently-tagged anti-IgG secondary antibody) produces when binding to a particular protein on the HuProtTM array. Z-scores are described in units of standard deviations (SD’s) above the mean value of all signals generated on that array. If targets on HuProtTM are arranged in descending order of the Z-score, the S-score is the difference (also in units of SD’s) between the Z-score. S-score therefore represents the relative target specificity of a MAb to its intended target. A MAb is considered to specific to its intended target, if the MAb has an S-score of at least 2.5. For example, if a MAb binds to protein X with a Z-score of 43 and to protein Y with a Z-score of 14, then the S-score for the binding of that MAb to protein X is equal to 29.
Mouse Anti-CD163 Monoclonal Antibody, Test Data – Cat# MBS4380519

Product References and Citations for anti-CD163 antibody

Sean K. Lau, Peiguo G. Chu, and Lawrence M. Weiss. CD163: A Specific Marker of Macrophages in Paraffin-Embedded Tissue Samples Am J Clin Pathol 2004; 122:794-801.

Other Notes

Small volumes of anti-CD163 antibody vial(s) may occasionally become entrapped in the seal of the product vial during shipment and storage. If necessary, briefly centrifuge the vial on a tabletop centrifuge to dislodge any liquid in the container`s cap. Certain products may require to ship with dry ice and additional dry ice fee may apply.

Additional Details

NCBI/Uniprot data below describe general gene information for CD163. It may not necessarily be applicable to this product.

NCBI GI #
NCBI GeneID
NCBI Accession #
UniProt Primary Accession #
UniProt Secondary Accession #
UniProt Related Accession #
GenBank Nucleotide #
NCBI Official Full Name
scavenger receptor cysteine-rich type 1 protein M130 isoform a
NCBI Official Synonym Full Names
CD163 molecule
NCBI Official Symbol
CD163
NCBI Official Synonym Symbols
M130; MM130; SCARI1
UniProt Protein Name
Scavenger receptor cysteine-rich type 1 protein M130
UniProt Synonym Protein Names
Hemoglobin scavenger receptor; CD_antigen: CD163
UniProt Gene Name
CD163
UniProt Synonym Gene Names
M130; sCD163
NCBI Protein Information
scavenger receptor cysteine-rich type 1 protein M130

NCBI Summary for CD163

The protein encoded by this gene is a member of the scavenger receptor cysteine-rich (SRCR) superfamily, and is exclusively expressed in monocytes and macrophages. It functions as an acute phase-regulated receptor involved in the clearance and endocytosis of hemoglobin/haptoglobin complexes by macrophages, and may thereby protect tissues from free hemoglobin-mediated oxidative damage. This protein may also function as an innate immune sensor for bacteria and inducer of local inflammation. Alternatively spliced transcript variants encoding different isoforms have been described for this gene. [provided by RefSeq, Aug 2011]
Show more

UniProt Comments for CD163

Acute phase-regulated receptor involved in clearance and endocytosis of hemoglobin/haptoglobin complexes by macrophages and may thereby protect tissues from free hemoglobin-mediated oxidative damage. May play a role in the uptake and recycling of iron, via endocytosis of hemoglobin/haptoglobin and subsequent breakdown of heme. Binds hemoglobin/haptoglobin complexes in a calcium-dependent and pH-dependent manner. Exhibits a higher affinity for complexes of hemoglobin and multimeric haptoglobin of HP*1F phenotype than for complexes of hemoglobin and dimeric haptoglobin of HP*1S phenotype. Induces a cascade of intracellular signals that involves tyrosine kinase-dependent calcium mobilization, inositol triphosphate production and secretion of IL6 and CSF1. Isoform 3 exhibits the higher capacity for ligand endocytosis and the more pronounced surface expression when expressed in cells.After shedding, the soluble form (sCD163) may play an anti-inflammatory role, and may be a valuable diagnostic parameter for monitoring macrophage activation in inflammatory conditions.MiscellaneousIntravenous lipopolysaccharide (LPS) produces a rapid rise of sCD163 in plasma of patient as it induces metalloproteinase-mediated shedding from monocytes surface. Long-term LPS infusion finally increases expression of the membrane-bound form on circulating monocytes.The soluble form (sCD163) in plasma is a novel parameter in diseases affecting macrophage function and monocyte/macrophage load in the body. The concentration of sCD163 is probably reflecting the number of macrophages of the 'alternative macrophage activation' phenotype with a high CD163 expression playing a major role in dampening the inflammatory response and scavenging components of damaged cells. This has initiated a number of clinical studies for evaluation of sCD163 as a disease marker in inflammatory conditions e.g. infection, autoimmune disease, transplantation, atherosclerosis and cancer.CautionIt is uncertain whether Met-1 or Met-6 is the initiator.
Show more

Precautions

All of MyBioSource's Products are for scientific laboratory research purposes and are not for diagnostic, therapeutics, prophylactic or in vivo use. Through your purchase, you expressly represent and warrant to MyBioSource that you will properly test and use any Products purchased from MyBioSource in accordance with industry standards. MyBioSource and its authorized distributors reserve the right to refuse to process any order where we reasonably believe that the intended use will fall outside of our acceptable guidelines.

Disclaimer

While every efforts were made to ensure the accuracy of the information provided in this datasheet, MyBioSource will not be liable for any omissions or errors contained herein. MyBioSource reserves the right to make changes to this datasheet at any time without prior notice.

It is the responsibility of the customer to report product performance issues to MyBioSource within 30 days of receipt of the product. Please visit our Terms & Conditions page for more information.

Product Note

Select online data sheet information is drawn from bioinformatics databases, occasionally resulting in ambiguous or non-relevant product information. It is the responsibility of the customer to review, verify, and evaluate the information to make sure it matches their requirements before purchasing the kit. Our ELISA Kit assays are dynamic research tools and sometimes they may be updated and improved. If the format of this assay is important to you then please request the current manual or contact our technical support team with a presales inquiry before placing an order. We will confirm the current details of the assay. We cannot guarantee the sample manual posted online is the most current manual, it is intended to serve as an example only. Please refer to the instructions For Use provided with the assay kit for precise details.

Product PubMed Publications

Request a Quote

Please fill out the form below and our representative will get back to you shortly.

MBS000000
Contact Us

Please fill out the form below and our representative will get back to you shortly.

MBS000000