• Call +1.858.633.0165 or Fax +1.858.633.0166 or Contact Us

Glucoprotein 130 (gp130) ELISA Kit for Human

For Research Use Only. Not for use in diagnostic procedures. Catalog #: MBS451741

Intended Uses: The kit is a sandwich enzyme immunoassay for in vitro quantitative measurement of gp130 in human serum, plasma and other biological fluids.Principle of the Assay: The microtiter plate provided in this kit has been pre-coated with an antibody… More details

$405 / 48 Tests +1 FREE 8GB USB

Product Documentation

PDF
Sample Manual Insert View PDF
PDF
Testing Data View PDF
PDF
Certificate of Analysis (COA) View PDF
PDF
QC Report View PDF
PDF
Material Safety Data Sheet View PDF
PDF
Technical Datasheet View PDF
PDF
Protocol View PDF

Product Overview

Online Datasheet in PDF
Product Name
Glucoprotein 130 (gp130), ELISA Kit
Full Product Name
Human Glucoprotein 130 (gp130) ELISA Kit
Product Gene Name
Product Synonym Names
BB2; CD54; P3.58; Human Rhinovirus Receptor
Species Reactivity
Human
Assay Type
Sandwich
Samples
Serum, plasma and other biological fluids.
Detection Range
0.312-20ng/mL
Sensitivity
0.115ng/mL
Specificity
This assay has high sensitivity and excellent specificity for detection of gp130. No significant cross-reactivity or interference between gp130 and analogues was observed.
Preparation and Storage
For unopened kit, all reagents should be kept according to the labels on vials. The TMB Substrate, Wash Buffer, Stop Solution should be stored at 4 degree C. All others should be stored at -20 degree C.
Inter-assay Precision
Inter-assay Precision (Precision between assays): 3 samples with low, middle and high level gp130 were tested on 3 different plates, 8 replicates in each plate. CV(%) = SD/meanX100. Inter-Assay: CV<12%
Intra-assay Precision
Intra-assay Precision (Precision within an assay): 3 samples with low, middle and high level gp130 were tested 20 times on one plate, respectively. Intra-Assay: CV<10%
Molecular Weight
96,276 Da
OMIM
M57230 mRNA
3D Structure
ModBase 3D Structure for P40189
ISO Certification
Manufactured in an ISO 13485:2003 and EN ISO 13485:2012 Certified Laboratory.

Typical Testing Data/Standard Curve (for reference only) of gp130 elisa kit

Human gp130 ELISA Kit – Cat# MBS451741

Other Notes

Small volumes of gp130 elisa kit vial(s) may occasionally become entrapped in the seal of the product vial during shipment and storage. If necessary, briefly centrifuge the vial on a tabletop centrifuge to dislodge any liquid in the container`s cap. Certain products may require to ship with dry ice and additional dry ice fee may apply.

Searchable Terms for gp130 purchase

MBS451741 is a ready-to-use microwell, strip-or-full plate ELISA (enzyme-linked immunosorbent assay) Kit for analyzing the presence of the Glucoprotein 130 (gp130) ELISA Kit target analytes in biological samples. The concentration gradients of the kit standards or positive controls render a theoretical kit detection range in biological research samples containing gp130. The ELISA analytical biochemical technique of the MBS451741 kit is based on gp130 antibody-gp130 antigen interactions (immunosorbency) and an HRP colorimetric detection system to detect gp130 antigen targets in samples. The ELISA Kit is designed to detect native, not recombinant, gp130. Appropriate sample types may include undiluted body fluids and/or tissue homogenates, secretions. Quality control assays assessing reproducibility identified the intra-assay CV (%) and inter-assay CV(%).

Additional Details

NCBI/Uniprot data below describe general gene information for gp130. It may not necessarily be applicable to this product.

NCBI GI #
NCBI GeneID
NCBI Accession #
UniProt Primary Accession #
UniProt Secondary Accession #
UniProt Related Accession #
GenBank Nucleotide #
NCBI Official Full Name
interleukin-6 receptor subunit beta isoform 3
NCBI Official Synonym Full Names
interleukin 6 signal transducer
NCBI Official Symbol
IL6ST
NCBI Official Synonym Symbols
CD130; GP130; CDW130; IL-6RB
UniProt Protein Name
Interleukin-6 receptor subunit beta
UniProt Synonym Protein Names
CDw130; Interleukin-6 signal transducer; Membrane glycoprotein 130; gp130; Oncostatin-M receptor subunit alpha; CD_antigen: CD130
UniProt Gene Name
IL6ST
UniProt Synonym Gene Names
IL-6 receptor subunit beta; IL-6R subunit beta; IL-6R-beta; IL-6RB; gp130
NCBI Protein Information
interleukin-6 receptor subunit beta

NCBI Summary for gp130

The protein encoded by this gene is a signal transducer shared by many cytokines, including interleukin 6 (IL6), ciliary neurotrophic factor (CNTF), leukemia inhibitory factor (LIF), and oncostatin M (OSM). This protein functions as a part of the cytokine receptor complex. The activation of this protein is dependent upon the binding of cytokines to their receptors. vIL6, a protein related to IL6 and encoded by the Kaposi sarcoma-associated herpesvirus, can bypass the interleukin 6 receptor (IL6R) and directly activate this protein. Knockout studies in mice suggest that this gene plays a critical role in regulating myocyte apoptosis. Alternatively spliced transcript variants have been described. A related pseudogene has been identified on chromosome 17. [provided by RefSeq, May 2014]
Show more

UniProt Comments for gp130

Signal-transducing molecule. The receptor systems for IL6, LIF, OSM, CNTF, IL11, CTF1 and BSF3 can utilize IL6ST for initiating signal transmission. Binding of IL6 to IL6R induces IL6ST homodimerization and formation of a high-affinity receptor complex, which activates Janus kinases (PubMed:2261637). That causes phosphorylation of IL6ST tyrosine residues which in turn activates STAT3 (PubMed:19915009, PubMed:23294003). Mediates signals which regulate immune response, hematopoiesis, pain control and bone metabolism (). Has a role in embryonic development (). Does not bind IL6 (PubMed:2261637). Essential for survival of motor and sensory neurons and for differentiation of astrocytes (). Required for expression of TRPA1 in nociceptive neurons (). Required for the maintenance of PTH1R expression in the osteoblast lineage and for the stimulation of PTH-induced osteoblast differentiation (). Required for normal trabecular bone mass and cortical bone composition ().
Show more

Precautions

All of MyBioSource's Products are for scientific laboratory research purposes and are not for diagnostic, therapeutics, prophylactic or in vivo use. Through your purchase, you expressly represent and warrant to MyBioSource that you will properly test and use any Products purchased from MyBioSource in accordance with industry standards. MyBioSource and its authorized distributors reserve the right to refuse to process any order where we reasonably believe that the intended use will fall outside of our acceptable guidelines.

Disclaimer

While every efforts were made to ensure the accuracy of the information provided in this datasheet, MyBioSource will not be liable for any omissions or errors contained herein. MyBioSource reserves the right to make changes to this datasheet at any time without prior notice.

It is the responsibility of the customer to report product performance issues to MyBioSource within 30 days of receipt of the product. Please visit our Terms & Conditions page for more information.

Product Note

Select online data sheet information is drawn from bioinformatics databases, occasionally resulting in ambiguous or non-relevant product information. It is the responsibility of the customer to review, verify, and evaluate the information to make sure it matches their requirements before purchasing the kit. Our ELISA Kit assays are dynamic research tools and sometimes they may be updated and improved. If the format of this assay is important to you then please request the current manual or contact our technical support team with a presales inquiry before placing an order. We will confirm the current details of the assay. We cannot guarantee the sample manual posted online is the most current manual, it is intended to serve as an example only. Please refer to the instructions For Use provided with the assay kit for precise details.

Product PubMed Publications

Request a Quote

Please fill out the form below and our representative will get back to you shortly.

MBS000000
Contact Us

Please fill out the form below and our representative will get back to you shortly.

MBS000000