• Call +1.858.633.0165 or Fax +1.858.633.0166 or Contact Us

B-Cell Cll/Lymphoma 3 (BCL3) ELISA Kit for Fish

For Research Use Only. Not for use in diagnostic procedures. Catalog #: MBS046050

Background/Introduction: This Quantitative Sandwich ELISA kit is only for in vitro research use only! This kit is intended to be used for determination the level of BCL3 (hereafter termed "analyte") in undiluted original Fish body fluids, tissue homogenates,… More details

Product Documentation

PDF
Sample Manual Insert View PDF
PDF
Testing Data View PDF
PDF
Certificate of Analysis (COA) View PDF
PDF
QC Report View PDF
PDF
Material Safety Data Sheet View PDF
PDF
Technical Datasheet View PDF
PDF
Protocol View PDF

Product Overview

Online Datasheet in PDF
Product Name
B-Cell Cll/Lymphoma 3 (BCL3), ELISA Kit
Full Product Name
Fish B-Cell Cll/Lymphoma 3 ELISA Kit
Product Gene Name
Species Reactivity
Fish
Assay Type
Sandwich
Samples
Undiluted original Fish body fluids, tissue homogenates, secretions or feces samples. This kit is NOT suitable for assaying non-biological sources of substances.
Detection Range
3.12 ng/ml - 100 ng/ml.
Sensitivity
1.0ng/ml.
Specificity
No significant cross-reactivity or interference between this analyte and analogues is observed.
Preparation and Storage
Store all reagents at 2-8 degree C
Inter-assay Precision
Inter-assay CV (%) is less than 15%. [CV(%) = SD/mean ×100].
Intra-assay Precision
Intra-assay CV (%) is less than 15%.
Molecular Weight
47,584 Da
Chromosome Location
Chromosome: 19; NC_000019.9 (45251978..45263301). Location: 19q13.1-q13.2
OMIM
109560
3D Structure
ModBase 3D Structure for P20749

Other Notes

Small volumes of BCL3 elisa kit vial(s) may occasionally become entrapped in the seal of the product vial during shipment and storage. If necessary, briefly centrifuge the vial on a tabletop centrifuge to dislodge any liquid in the container`s cap. Certain products may require to ship with dry ice and additional dry ice fee may apply.

Searchable Terms for BCL3 purchase

MBS046050 is a ready-to-use microwell, strip-or-full plate ELISA (enzyme-linked immunosorbent assay) Kit for analyzing the presence of the B-Cell Cll/Lymphoma 3 (BCL3) ELISA Kit target analytes in biological samples. The concentration gradients of the kit standards or positive controls render a theoretical kit detection range in biological research samples containing BCL3. The ELISA analytical biochemical technique of the MBS046050 kit is based on BCL3 antibody-BCL3 antigen interactions (immunosorbency) and an HRP colorimetric detection system to detect BCL3 antigen targets in samples. The ELISA Kit is designed to detect native, not recombinant, BCL3. Appropriate sample types may include undiluted body fluids and/or tissue homogenates, secretions. Quality control assays assessing reproducibility identified the intra-assay CV (%) and inter-assay CV(%).

Additional Details

NCBI/Uniprot data below describe general gene information for BCL3. It may not necessarily be applicable to this product.

NCBI GI #
NCBI GeneID
NCBI Accession #
UniProt Primary Accession #
UniProt Related Accession #
GenBank Nucleotide #
NCBI Official Full Name
B-cell lymphoma 3 protein
NCBI Official Synonym Full Names
B-cell CLL/lymphoma 3
NCBI Official Symbol
BCL3
NCBI Official Synonym Symbols
BCL4; D19S37
UniProt Protein Name
B-cell lymphoma 3 protein
UniProt Synonym Protein Names
Proto-oncogene BCL3
UniProt Gene Name
BCL3
UniProt Synonym Gene Names
BCL4; D19S37; BCL-3
UniProt Entry Name
BCL3_HUMAN
NCBI Protein Information
B-cell lymphoma 3 protein; BCL-3; proto-oncogene BCL3; B-cell leukemia/lymphoma 3; B-cell lymphoma 3-encoded protein; chronic lymphatic leukemia protein

NCBI Summary for BCL3

This gene is a proto-oncogene candidate. It is identified by its translocation into the immunoglobulin alpha-locus in some cases of B-cell leukemia. The protein encoded by this gene contains seven ankyrin repeats, which are most closely related to those found in I kappa B proteins. This protein functions as a transcriptional co-activator that activates through its association with NF-kappa B homodimers. The expression of this gene can be induced by NF-kappa B, which forms a part of the autoregulatory loop that controls the nuclear residence of p50 NF-kappa B. [provided by RefSeq, Jul 2008]
Show more

UniProt Comments for BCL3

Function: Contributes to the regulation of transcriptional activation of NF-kappa-B target genes. In the cytoplasm, inhibits the nuclear translocation of the NF-kappa-B p50 subunit. In the nucleus, acts as transcriptional activator that promotes transcription of NF-kappa-B target genes. Contributes to the regulation of cell proliferation

By similarity. Ref.4

Subunit structure: Component of a complex consisting of the NF-kappa-B p52-p52 homodimer and BCL3. Component of a complex consisting of the NF-kappa-B p50-p50 homodimer and BCL3. Interacts with N4BP2, COPS5 and PIR. Interacts with CYLD

By similarity. Ref.4 Ref.5 Ref.6 Ref.7

Subcellular location: Nucleus. Cytoplasm

By similarity. Cytoplasm › perinuclear region

By similarity. Note: Ubiquitination via 'Lys-63'-linked ubiquitin chains is required for nuclear accumulation

By similarity.

Post-translational modification: Polyubiquitinated. Ubiquitination via 'Lys-63'-linked ubiquitin chains is required for nuclear accumulation. Deubiquitinated by CYLD, which acts on 'Lys-63'-linked ubiquitin chains. Deubiquitination by CYLD prevents nuclear accumulation

By similarity.Activated by phosphorylation.

Involvement in disease: A chromosomal aberration involving BCL3 may be a cause of B-cell chronic lymphocytic leukemia (B-CLL). Translocation t(14;19)(q32;q13.1) with immunoglobulin gene regions.

Sequence similarities: Contains 7 ANK repeats.

Caution: It is uncertain whether Met-1 or Met-9 is the initiator.

Sequence caution: The sequence AAA51815.1 differs from that shown. Reason: Erroneous initiation. Translation N-terminally extended.The sequence AAA51816.1 differs from that shown. Reason: Erroneous initiation. Translation N-terminally extended.The sequence AAH64993.1 differs from that shown. Reason: Erroneous initiation. Translation N-terminally extended.
Show more

Precautions

All of MyBioSource's Products are for scientific laboratory research purposes and are not for diagnostic, therapeutics, prophylactic or in vivo use. Through your purchase, you expressly represent and warrant to MyBioSource that you will properly test and use any Products purchased from MyBioSource in accordance with industry standards. MyBioSource and its authorized distributors reserve the right to refuse to process any order where we reasonably believe that the intended use will fall outside of our acceptable guidelines.

Disclaimer

While every efforts were made to ensure the accuracy of the information provided in this datasheet, MyBioSource will not be liable for any omissions or errors contained herein. MyBioSource reserves the right to make changes to this datasheet at any time without prior notice.

It is the responsibility of the customer to report product performance issues to MyBioSource within 30 days of receipt of the product. Please visit our Terms & Conditions page for more information.

Product Note

Select online data sheet information is drawn from bioinformatics databases, occasionally resulting in ambiguous or non-relevant product information. It is the responsibility of the customer to review, verify, and evaluate the information to make sure it matches their requirements before purchasing the kit. Our ELISA Kit assays are dynamic research tools and sometimes they may be updated and improved. If the format of this assay is important to you then please request the current manual or contact our technical support team with a presales inquiry before placing an order. We will confirm the current details of the assay. We cannot guarantee the sample manual posted online is the most current manual, it is intended to serve as an example only. Please refer to the instructions For Use provided with the assay kit for precise details.

Product PubMed Publications

Request a Quote

Please fill out the form below and our representative will get back to you shortly.

MBS000000
Contact Us

Please fill out the form below and our representative will get back to you shortly.

MBS000000