• Call +1.858.633.0165 or Fax +1.858.633.0166 or Contact Us

CD106 Antibody – Mouse Monoclonal

For Research Use Only. Not for use in diagnostic procedures. Catalog #: MBS666601

Information: Human CD106 is an endothelial adhesion molecule that binds to alpha 4 beta 1 & alpha 4 beta 7 integrins (VLA-4) and promotes adhesion of lymphocytes, monocytes, eosinophils and basophils. CD106 is also found on follicular dendritic cells,… More details

$530 / 120 Tests +1 FREE 8GB USB
Product Documentation
PDF
Sample Manual Insert View PDF
PDF
Testing Data View PDF
PDF
Certificate of Analysis (COA) View PDF
PDF
QC Report View PDF
PDF
Material Safety Data Sheet View PDF
PDF
Technical Datasheet View PDF
PDF
Protocol View PDF

Product Overview

Online Datasheet in PDF
Product Name
CD106, Monoclonal Antibody
Full Product Name
anti-human CD106-R-PE
Product Gene Name
Product Synonym Names
Monoclonal anti-human CD106(VCAM-1)/R-PE
Clonality
Monoclonal
Isotype
IgG1
Clone Number
1.G11B1
Host
Mouse
Species Reactivity
Human, Pig
Preparation and Storage
Store at 2 - 5 degree C. Do not freeze! Protect from light.
Product should retain activity for at least 12 months after shipping date when stored as recommended.
Performance
Cultured human umbilical cord vein endothelial cells were stimulated 4 hours with 10 ng/ml Phorbol 12-Myristate 13-Acetate. Five x 105 cells per tube were harvested, washed and incubated 45 minutes on ice with 80 ul of anti-CD106/R-PE at a 1:50 dilution (10ug/ml). Cells were washed three times, fixed and analyzed by FACS. Cells stained positive with a mean shift of 1.36 log10 fluorescent units when compared to a Mouse IgG1/R-PE negative control at a similar concentration. Binding was blocked when cells were pre incubated 10 minutes with 20 ul of 0.5 mg/ml anti-CD106 antibody.
Conjugation
PE
Production
Protein A purified antibody from tissue culture supernatant was conjugated to R-Phycoerythrin through a sulfo-ester linkage. Unconjugated antibody was removed using size exclusion chromatography. Antibody conjugate is at 0.5 mg/ml with an A565/A280 ratio of 3.53.
Buffer
50 mM Sodium Phosphate pH 7.5, 500 mM Potassium Chloride, 150mM NaCl, 15% Glycerol, 0.2% BSA, 0.04% NaN3 (as a preservative).
Immunogen
Human endothelial cells
Applications Tested/Suitable for anti-CD106 antibody
Flow Cytometry (FC/FACS), Western Blot (WB), ELISA (EIA), Immunohistochemistry (IHC), Blocking
Application Notes for anti-CD106 antibody
Dilution: 1:50 (or use 1.6ul of concentrated reagent per 5x105-cell test)

Testing Data of anti-CD106 antibody

Mouse Anti-CD106 Monoclonal Antibody – Cat# MBS666601

Product References and Citations for anti-CD106 antibody

M.H. Thornhill, D.O. Haskard, (1991) J Immunol 146: 592-598. Leukocyte Typing V (S.F. Schlossman, et al, eds.) Oxford University Press, Oxford, (1995) p. 1764-1767. M. Nagata, et al, (1995) J Immunol 155: 2194-2202. H.E. Chuluyan, et al, (1995) J Immunol 155: 3135-314.

Other Notes

Small volumes of anti-CD106 antibody vial(s) may occasionally become entrapped in the seal of the product vial during shipment and storage. If necessary, briefly centrifuge the vial on a tabletop centrifuge to dislodge any liquid in the container`s cap. Certain products may require to ship with dry ice and additional dry ice fee may apply.

Searchable Terms for CD106 purchase

MBS666601 is an antibody targeting CD106. Also known as anti-human CD106-R-PE. Reactive in Human, Pig. Host: Mouse.

Additional Details

NCBI/Uniprot data below describe general gene information for CD106. It may not necessarily be applicable to this product.

Precautions

All of MyBioSource's Products are for scientific laboratory research purposes and are not for diagnostic, therapeutics, prophylactic or in vivo use. Through your purchase, you expressly represent and warrant to MyBioSource that you will properly test and use any Products purchased from MyBioSource in accordance with industry standards. MyBioSource and its authorized distributors reserve the right to refuse to process any order where we reasonably believe that the intended use will fall outside of our acceptable guidelines.

Disclaimer

While every efforts were made to ensure the accuracy of the information provided in this datasheet, MyBioSource will not be liable for any omissions or errors contained herein. MyBioSource reserves the right to make changes to this datasheet at any time without prior notice.

It is the responsibility of the customer to report product performance issues to MyBioSource within 30 days of receipt of the product. Please visit our Terms & Conditions page for more information.

Product Note

Select online data sheet information is drawn from bioinformatics databases, occasionally resulting in ambiguous or non-relevant product information. It is the responsibility of the customer to review, verify, and evaluate the information to make sure it matches their requirements before purchasing the kit. Our ELISA Kit assays are dynamic research tools and sometimes they may be updated and improved. If the format of this assay is important to you then please request the current manual or contact our technical support team with a presales inquiry before placing an order. We will confirm the current details of the assay. We cannot guarantee the sample manual posted online is the most current manual, it is intended to serve as an example only. Please refer to the instructions For Use provided with the assay kit for precise details.
Request a Quote

Please fill out the form below and our representative will get back to you shortly.

MBS000000
Contact Us

Please fill out the form below and our representative will get back to you shortly.

MBS000000