• Call +1.858.633.0165 or Fax +1.858.633.0166 or Contact Us

Retinoic Acid ELISA Kit for Human

For Research Use Only. Not for use in diagnostic procedures. Popular Catalog #: MBS705877

Principle of the Assay: This assay employs the competitive inhibition enzyme immunoassay technique. The microtiter plate provided in this kit has been pre-coated with an antibody specific to retinoic acid. Standards or samples are added to the appropriate… More details

$295 / 24-Strip-Wells (LIMIT 1) +1 FREE 8GB USB

Product Documentation

PDF
Sample Manual Insert View PDF
PDF
Testing Data View PDF
PDF
Certificate of Analysis (COA) View PDF
PDF
QC Report View PDF
PDF
Material Safety Data Sheet View PDF
PDF
Technical Datasheet View PDF
PDF
Protocol View PDF

Product Overview

Online Datasheet in PDF
Product Name
Retinoic Acid, ELISA Kit
Full Product Name
Human Retinoic Acid ELISA Kit
Product Synonym Names
Human Retinoic Acid ELISA Kit; Retinoic Acid
Species Reactivity
Human
Assay Type
Competitive
Samples
Serum, plasma
Detection Range
6.25 pg/ml-100 pg/ml
Sensitivity
< 3.12pg/ml
Specificity
This assay has high sensitivity and excellent specificity for detection of human retinoic acid. No significant cross-reactivity or interference between human retinoic acid and analogues was observed.
Preparation and Storage
Unopened test kits should be stored at 2 to 8 degree C upon receipt. Please refer to pdf manual for further storage instructions.
Inter-assay Precision
Inter-assay Precision (Precision between assays): CV%<10%. Three samples of known concentration were tested in twenty assays to assess.
Intra-assay Precision
Intra-assay Precision (Precision within an assay): CV%<8%. Three samples of known concentration were tested twenty times on one plate to assess.
ISO Certification
Manufactured in an ISO 9001:2015 Certified Laboratory.

Typical Testing Data/Standard Curve (for reference only) of Retinoic Acid elisa kit

Human ELISA Kit – Cat# MBS705877

Product References and Citations for Retinoic Acid elisa kit

Association of serum retinoic acid with hepatic steatosis and liver injury in nonalcoholic fatty liver disease. Yan Liu, Hongen Chen, Jingjing Wang, Wenjing Zhou, Ruifang Sun, and Min Xia (2015)
Differentiation of neuronal stem cells into motor neurons using electrospun poly-L-lactic acid/gelatin scaffold. Loïc Binan, Charlène Tendey, Gregory De Crescenzo, Rouwayda El Ayoubi, Abdellah Ajji, Mario Jolicoeur (2014)< br>Circulating retinoic acid levels and the development of metabolic syndrome. Yan Liu, Hongen Chen, Di Mu, Jiahua Fan, Jiayi Song, Yuan Zhong, Di Li, and Min Xia (2016)

Other Notes

Small volumes of Retinoic Acid elisa kit vial(s) may occasionally become entrapped in the seal of the product vial during shipment and storage. If necessary, briefly centrifuge the vial on a tabletop centrifuge to dislodge any liquid in the container`s cap. Certain products may require to ship with dry ice and additional dry ice fee may apply.

Searchable Terms for Retinoic Acid purchase

MBS705877 is a ready-to-use microwell, strip plate ELISA (enzyme-linked immunosorbent assay) Kit for analyzing the presence of the Retinoic Acid, ELISA Kit target analytes in biological samples. The concentration gradients of the kit standards or positive controls render a theoretical kit detection range in biological research samples containing Retinoic Acid. The ELISA analytical biochemical technique of the MBS705877 kit is based on Retinoic Acid antibody-Retinoic Acid antigen interactions (immunosorbency) and an HRP colorimetric detection system to detect Retinoic Acid antigen targets in samples. The ELISA Kit is designed to detect native, not recombinant, Retinoic Acid. Appropriate sample types may include undiluted body fluids and/or tissue homogenates, secretions. Quality control assays assessing reproducibility identified the intra-assay CV (%) and inter-assay CV(%). Intended use of this ELISA Kit is quantitative determination of endogenous human retinoic acid in serum, EDTA plasma, and heparin plasma.

Retinoic acid is physiologically active metabolite of retinol (vitamin A) that is naturally produced by enzymatic oxidation of retinol.

Retinoic acid controls genes’ transcription by binding to DNA through retinoic acid receptors and plays important role in growth and development.

Test system is designed as competitive ELISA and concentration of retinoic acid is measured using antibodies specific to target analyte.

Product contains microwell plate pre-coated with antibodies against retinoic acid, and all reagents required for its quantification, including sample and reagent diluents, and wash solution.

Assay kit provides colorimetric detection of analyte using retinoic acid conjugated to HRP, and TMB as its substrate solution.

Minimal detectable concentration of ELISA kit is 0.3125ng/mL, and its reportable range is 0.625 - 10ng/mL; concentrated calibrator’s preparation for standard curve is supplied in lyophilized form and requires dilution for making working levels of calibrators.

Intra- and inter- assay CV values, reported as kit’s precision characteristics, are not greater than 8% and 10%, respectively.

Assay doesn’t show significant cross-reactivity with analogous molecules.

ELISA kit and its reagents and components require refrigeration and must be stored at 2-8°C until indicated expiration date.

Additional Details

NCBI/Uniprot data below describe general gene information for Retinoic Acid. It may not necessarily be applicable to this product.

Precautions

All of MyBioSource's Products are for scientific laboratory research purposes and are not for diagnostic, therapeutics, prophylactic or in vivo use. Through your purchase, you expressly represent and warrant to MyBioSource that you will properly test and use any Products purchased from MyBioSource in accordance with industry standards. MyBioSource and its authorized distributors reserve the right to refuse to process any order where we reasonably believe that the intended use will fall outside of our acceptable guidelines.

Disclaimer

While every efforts were made to ensure the accuracy of the information provided in this datasheet, MyBioSource will not be liable for any omissions or errors contained herein. MyBioSource reserves the right to make changes to this datasheet at any time without prior notice.

It is the responsibility of the customer to report product performance issues to MyBioSource within 30 days of receipt of the product. Please visit our Terms & Conditions page for more information.

Product Note

Select online data sheet information is drawn from bioinformatics databases, occasionally resulting in ambiguous or non-relevant product information. It is the responsibility of the customer to review, verify, and evaluate the information to make sure it matches their requirements before purchasing the kit. Our ELISA Kit assays are dynamic research tools and sometimes they may be updated and improved. If the format of this assay is important to you then please request the current manual or contact our technical support team with a presales inquiry before placing an order. We will confirm the current details of the assay. We cannot guarantee the sample manual posted online is the most current manual, it is intended to serve as an example only. Please refer to the instructions For Use provided with the assay kit for precise details.
Request a Quote

Please fill out the form below and our representative will get back to you shortly.

MBS000000
Contact Us

Please fill out the form below and our representative will get back to you shortly.

MBS000000