• Call +1.858.633.0165 or Fax +1.858.633.0166 or Contact Us

HLA Class II Histocompatibility Antigen, Dr Alpha Chain (HLA-DRA) ELISA Kit for Human

For Research Use Only. Not for use in diagnostic procedures. Popular Catalog #: MBS706908

Principle of the Assay: This assay employs the quantitative sandwich enzyme immunoassay technique. Antibody specific for HLA-DRA has been pre-coated onto a microplate. Standards and samples are pipetted into the wells and any HLA-DRA present is bound by the… More details

$295 / 24-Strip-Wells (LIMIT 1) +1 FREE 8GB USB

Product Documentation

PDF
Sample Manual Insert View PDF
PDF
Testing Data View PDF
PDF
Certificate of Analysis (COA) View PDF
PDF
QC Report View PDF
PDF
Material Safety Data Sheet View PDF
PDF
Technical Datasheet View PDF
PDF
Protocol View PDF

Product Overview

Online Datasheet in PDF
Product Name
HLA class II histocompatibility antigen, DR alpha chain (HLA-DRA), ELISA Kit
Full Product Name
Human HLA class II histocompatibility antigen, DR alpha chain, HLA-DRA ELISA Kit
Product Gene Name
Product Synonym Names
Human HLA class II histocompatibility antigen; DR alpha chain (HLA-DRA) ELISA kit; DASS-397D15.1; HLA-DRA1; HLA class II histocompatibility antigen; DR alpha chain; MHC cell surface glycoprotein; histocompatibility antigen HLA-DR alpha major histocompatibility complex; class II; DR alpha (HLA-DRA) ; HLA class II histocompatibility antigen; DR alpha chain
Species Reactivity
Human
Assay Type
Quantitative Sandwich
Samples
Serum, plasma, tissue homogenates
Detection Range
18.75 pg/ml-1200 pg/ml
Sensitivity
<4.68 pg/ml
Specificity
This assay has high sensitivity and excellent specificity for detection of human HLA-DRA. No significant cross-reactivity or interference between human HLA-DRA and analogues was observed.
Preparation and Storage
Unopened test kits should be stored at 2 to 8 degree C upon receipt. Please refer to pdf manual for further storage instructions.
Inter-assay Precision
Inter-assay Precision (Precision between assays): CV%<10%. Three samples of known concentration were tested in twenty assays to assess.
Intra-assay Precision
Intra-assay Precision (Precision within an assay): CV%<8%. Three samples of known concentration were tested twenty times on one plate to assess.
Molecular Weight
28,607 Da
OMIM
gene 610424
3D Structure
ModBase 3D Structure for P01903
ISO Certification
Manufactured in an ISO 9001:2015 Certified Laboratory.

Typical Testing Data/Standard Curve (for reference only) of HLA-DRA elisa kit

Human HLA-DRA ELISA Kit – Cat# MBS706908

Other Notes

Small volumes of HLA-DRA elisa kit vial(s) may occasionally become entrapped in the seal of the product vial during shipment and storage. If necessary, briefly centrifuge the vial on a tabletop centrifuge to dislodge any liquid in the container`s cap. Certain products may require to ship with dry ice and additional dry ice fee may apply.

Searchable Terms for HLA-DRA purchase

MBS706908 is a ready-to-use microwell, strip plate ELISA (enzyme-linked immunosorbent assay) Kit for analyzing the presence of the HLA class II histocompatibility antigen, DR alpha chain (HLA-DRA) ELISA Kit target analytes in biological samples. The concentration gradients of the kit standards or positive controls render a theoretical kit detection range in biological research samples containing HLA-DRA. The ELISA analytical biochemical technique of the MBS706908 kit is based on HLA-DRA antibody-HLA-DRA antigen interactions (immunosorbency) and an HRP colorimetric detection system to detect HLA-DRA antigen targets in samples. The ELISA Kit is designed to detect native, not recombinant, HLA-DRA. Appropriate sample types may include undiluted body fluids and/or tissue homogenates, secretions. Quality control assays assessing reproducibility identified the intra-assay CV (%) and inter-assay CV(%).

Additional Details

NCBI/Uniprot data below describe general gene information for HLA-DRA. It may not necessarily be applicable to this product.

NCBI GI #
NCBI GeneID
NCBI Accession #
UniProt Primary Accession #
UniProt Secondary Accession #
UniProt Related Accession #
GenBank Nucleotide #
NCBI Official Full Name
HLA class II histocompatibility antigen, DR alpha chain
NCBI Official Synonym Full Names
major histocompatibility complex, class II, DR alpha
NCBI Official Symbol
HLA-DRA
NCBI Official Synonym Symbols
MLRW; HLA-DRA1
UniProt Protein Name
HLA class II histocompatibility antigen, DR alpha chain
UniProt Synonym Protein Names
MHC class II antigen DRA
UniProt Gene Name
HLA-DRA
UniProt Synonym Gene Names
HLA-DRA1
UniProt Entry Name
DRA_HUMAN
NCBI Protein Information
HLA class II histocompatibility antigen, DR alpha chain; MHC class II antigen DRA; MHC cell surface glycoprotein; histocompatibility antigen HLA-DR alpha

NCBI Summary for HLA-DRA

HLA-DRA is one of the HLA class II alpha chain paralogues. This class II molecule is a heterodimer consisting of an alpha and a beta chain, both anchored in the membrane. It plays a central role in the immune system by presenting peptides derived from extracellular proteins. Class II molecules are expressed in antigen presenting cells (APC: B lymphocytes, dendritic cells, macrophages). The alpha chain is approximately 33-35 kDa and its gene contains 5 exons. Exon 1 encodes the leader peptide, exons 2 and 3 encode the two extracellular domains, and exon 4 encodes the transmembrane domain and the cytoplasmic tail. DRA does not have polymorphisms in the peptide binding part and acts as the sole alpha chain for DRB1, DRB3, DRB4 and DRB5. [provided by RefSeq, Jul 2008]
Show more

UniProt Comments for HLA-DRA

Function: Binds peptides derived from antigens that access the endocytic route of antigen presenting cells (APC) and presents them on the cell surface for recognition by the CD4 T-cells. The peptide binding cleft accommodates peptides of 10-30 residues. The peptides presented by MHC class II molecules are generated mostly by degradation of proteins that access the endocytic route, where they are processed by lysosomal proteases and other hydrolases. Exogenous antigens that have been endocytosed by the APC are thus readily available for presentation via MHC II molecules, and for this reason this antigen presentation pathway is usually referred to as exogenous. As membrane proteins on their way to degradation in lysosomes as part of their normal turn-over are also contained in the endosomal/lysosomal compartments, exogenous antigens must compete with those derived from endogenous components. Autophagy is also a source of endogenous peptides, autophagosomes constitutively fuse with MHC class II loading compartments. In addition to APCs, other cells of the gastrointestinal tract, such as epithelial cells, express MHC class II molecules and CD74 and act as APCs, which is an unusual trait of the GI tract. To produce a MHC class II molecule that presents an antigen, three MHC class II molecules (heterodimers of an alpha and a beta chain) associate with a CD74 trimer in the ER to form a heterononamer. Soon after the entry of this complex into the endosomal/lysosomal system where antigen processing occurs, CD74 undergoes a sequential degradation by various proteases, including CTSS and CTSL, leaving a small fragment termed CLIP (class-II-associated invariant chain peptide). The removal of CLIP is facilitated by HLA-DM via direct binding to the alpha-beta-CLIP complex so that CLIP is released. HLA-DM stabilizes MHC class II molecules until primary high affinity antigenic peptides are bound. The MHC II molecule bound to a peptide is then transported to the cell membrane surface. In B-cells, the interaction between HLA-DM and MHC class II molecules is regulated by HLA-DO. Primary dendritic cells (DCs) also to express HLA-DO. Lysosomal microenvironment has been implicated in the regulation of antigen loading into MHC II molecules, increased acidification produces increased proteolysis and efficient peptide loading.
Show more

Precautions

All of MyBioSource's Products are for scientific laboratory research purposes and are not for diagnostic, therapeutics, prophylactic or in vivo use. Through your purchase, you expressly represent and warrant to MyBioSource that you will properly test and use any Products purchased from MyBioSource in accordance with industry standards. MyBioSource and its authorized distributors reserve the right to refuse to process any order where we reasonably believe that the intended use will fall outside of our acceptable guidelines.

Disclaimer

While every efforts were made to ensure the accuracy of the information provided in this datasheet, MyBioSource will not be liable for any omissions or errors contained herein. MyBioSource reserves the right to make changes to this datasheet at any time without prior notice.

It is the responsibility of the customer to report product performance issues to MyBioSource within 30 days of receipt of the product. Please visit our Terms & Conditions page for more information.

Product Note

Select online data sheet information is drawn from bioinformatics databases, occasionally resulting in ambiguous or non-relevant product information. It is the responsibility of the customer to review, verify, and evaluate the information to make sure it matches their requirements before purchasing the kit. Our ELISA Kit assays are dynamic research tools and sometimes they may be updated and improved. If the format of this assay is important to you then please request the current manual or contact our technical support team with a presales inquiry before placing an order. We will confirm the current details of the assay. We cannot guarantee the sample manual posted online is the most current manual, it is intended to serve as an example only. Please refer to the instructions For Use provided with the assay kit for precise details.

Product PubMed Publications

Request a Quote

Please fill out the form below and our representative will get back to you shortly.

MBS000000
Contact Us

Please fill out the form below and our representative will get back to you shortly.

MBS000000