• Call +1.858.633.0165 or Fax +1.858.633.0166 or Contact Us

Connexin 43 (CX43) ELISA Kit for Mouse

For Research Use Only. Not for use in diagnostic procedures. Catalog #: MBS729401

Principle of the Assay: CX43 ELISA kit applies the competitive enzyme immunoassay technique utilizing a polyclonal anti-CX43 antibody and an CX43-HRP conjugate. The assay sample and buffer are incubated together with CX43-HRP conjugate in pre-coated plate for… More details

$580 / 48-Strip-Wells +1 FREE 8GB USB

Product Documentation

PDF
Sample Manual Insert View PDF
PDF
Testing Data View PDF
PDF
Certificate of Analysis (COA) View PDF
PDF
QC Report View PDF
PDF
Material Safety Data Sheet View PDF
PDF
Technical Datasheet View PDF
PDF
Protocol View PDF

Product Overview

Online Datasheet in PDF
Product Name
Connexin 43 (CX43), ELISA Kit
Full Product Name
Mouse Connexin 43 ELISA Kit
Product Gene Name
Species Reactivity
Mouse
Assay Type
Quantitative Competitive
Samples
Serum, plasma, cell culture supernatants, body fluid and tissue homogenate
Sensitivity
0.1 ng/ml
Specificity
This assay has high sensitivity and excellent specificity for detection of CX43. No significant cross-reactivity or interference between CX43 and analogues was observed. NOTE: Limited by current skills and knowledge, it is impossible for us to complete the cross-reactivity detection between CX43 and all the analogues, therefore, cross reaction may still exist in some cases.
Preparation and Storage
Store all reagents at 2-8 degree C
Molecular Weight
43,455 Da
Chromosome Location
Chromosome: 20; NC_007131.5 (40746894..40752184, complement). Location: chromosome: 20
3D Structure
ModBase 3D Structure for O57474
Sample Preparation
We suggest pre-experimenting with neat (undiluted) samples, 1:2 or 1:4 dilutions. Please avoid diluting your samples more than 1:10 as it would exceed the dilution limit set for this kit. If the expected concentration of the target is beyond the detection range of the kit, please contact our technical support team

Product Categories/Family for CX43 elisa kit

ISO Certification
Manufactured in an ISO 13485:2016 Certified Laboratory.

Typical Testing Data/Standard Curve (for reference only) of CX43 elisa kit

Mouse CX43 ELISA Kit – Cat# MBS729401

Other Notes

Small volumes of CX43 elisa kit vial(s) may occasionally become entrapped in the seal of the product vial during shipment and storage. If necessary, briefly centrifuge the vial on a tabletop centrifuge to dislodge any liquid in the container`s cap. Certain products may require to ship with dry ice and additional dry ice fee may apply.

Searchable Terms for CX43 purchase

MBS729401 is a ready-to-use microwell, strip plate ELISA (enzyme-linked immunosorbent assay) Kit for analyzing the presence of the Connexin 43 (CX43) ELISA Kit target analytes in biological samples. The concentration gradients of the kit standards or positive controls render a theoretical kit detection range in biological research samples containing CX43. The ELISA analytical biochemical technique of the MBS729401 kit is based on CX43 antibody-CX43 antigen interactions (immunosorbency) and an HRP colorimetric detection system to detect CX43 antigen targets in samples. The ELISA Kit is designed to detect native, not recombinant, CX43. Appropriate sample types may include undiluted body fluids and/or tissue homogenates, secretions. Quality control assays assessing reproducibility identified the intra-assay CV (%) and inter-assay CV(%). Intended use of this ELISA Kit is quantitative detection of murine connexin 43.

Kit’s target analyte, connexin 43, is one of major integral membrane proteins that form gap junction channels to provide inter-cellular communication such as exchange of small molecules and ions between adjacent cells. It’s expressed in variable cell types and plays important role in development, differentiation, and metabolic homeostasis.

Connexin 43 is listed in NCBI and UniProt data bases as gap junction alpha-1 protein, short fin protein; gap junction protein, and Cx43.

Murine connexin 43 test system is designed as sandwich-type ELISA and concentration of connexin 43 is measured using pair of antibodies specific to target protein.

Kit is applicable for testing connexin 43 in serum, plasma, cell culture supernatants, bodily fluids, and tissue homogenates.

Product contains microwell plate pre-coated with monoclonal capture antibodies against connexin 43 and all reagents required for its quantification, including sample and reagent diluents, and wash solution.

Assay kit provides colorimetric detection of connexin 43 using polyclonal detector antibodies against connexin 43 conjugated to HRP, and TMB as its substrate solution.

Minimal detectable concentration of ELISA kit is 1pg/mL; kits are supplied with six levels of liquid calibrators between 0 and 2500pg/mL.

Intra- and inter-lot assay CV values, reported as kit’s precision characteristics, are not greater than 9% and 10%, respectively.

Assay doesn’t show significant cross-reactivity with analogous molecules.

ELISA kit and its reagents and components require refrigeration and must be stored at 2-8°C until indicated expiration date.

Additional Details

NCBI/Uniprot data below describe general gene information for CX43. It may not necessarily be applicable to this product.

NCBI GI #
NCBI GeneID
NCBI Accession #
UniProt Primary Accession #
UniProt Secondary Accession #
UniProt Related Accession #
NCBI Official Full Name
Cx43 protein
NCBI Official Synonym Full Names
connexin 43
NCBI Official Symbol
cx43
NCBI Official Synonym Symbols
gja1; cx43a1; zfCx43.3
UniProt Protein Name
Gap junction alpha-1 protein
UniProt Synonym Protein Names
Connexin-43; Cx43; Short fin protein
UniProt Gene Name
gja1
UniProt Synonym Gene Names
cx43; shf; sof; Cx43
UniProt Entry Name
CXA1_DANRE
NCBI Protein Information
gap junction alpha-1 protein; shf; sof; connexin-43; etID309742.9; short fin protein; gap junction protein, alpha 1

UniProt Comments for CX43

Function: One gap junction consists of a cluster of closely packed pairs of transmembrane channels, the connexons, through which materials of low MW diffuse from one cell to a neighboring cell. Ref.1Plays a role in regulation of fin bone size and growth. Ref.1

Subunit structure: A connexon is composed of a hexamer of connexins.

Subcellular location: Cell membrane; Multi-pass membrane protein. Cell junction › gap junction.

Tissue specificity: Expressed in adult ovary, heart, lens and liver. In growing caudal fins, expressed in cells flanking the germinal region of newly growing segments and in osteoblasts at segment boundaries. Ref.1 Ref.2 Ref.5

Developmental stage: Expressed both maternally and zygotically. Zygotic expression is initiated before gastrulation and persists through to day 5 of development. Levels increase in late somitogenesis, and late embryonic and early larval stages. Embryonic expression is observed in many developing tissues and organs, including the notochord and brain, and heart and vasculature. Detected throughout the lens at 24 hours post-fertilization (hpf), but by 3-4 days development, restricted to the lateral epithelium and differentiating cells in the equatorial region. Ref.2 Ref.5

Miscellaneous: Morpholino knockdown of the protein results in heart folding defects, reduced hematopoiesis and small eyes.

Sequence similarities: Belongs to the connexin family. Alpha-type (group II) subfamily.
Show more

Precautions

All of MyBioSource's Products are for scientific laboratory research purposes and are not for diagnostic, therapeutics, prophylactic or in vivo use. Through your purchase, you expressly represent and warrant to MyBioSource that you will properly test and use any Products purchased from MyBioSource in accordance with industry standards. MyBioSource and its authorized distributors reserve the right to refuse to process any order where we reasonably believe that the intended use will fall outside of our acceptable guidelines.

Disclaimer

While every efforts were made to ensure the accuracy of the information provided in this datasheet, MyBioSource will not be liable for any omissions or errors contained herein. MyBioSource reserves the right to make changes to this datasheet at any time without prior notice.

It is the responsibility of the customer to report product performance issues to MyBioSource within 30 days of receipt of the product. Please visit our Terms & Conditions page for more information.

Product Note

Select online data sheet information is drawn from bioinformatics databases, occasionally resulting in ambiguous or non-relevant product information. It is the responsibility of the customer to review, verify, and evaluate the information to make sure it matches their requirements before purchasing the kit. Our ELISA Kit assays are dynamic research tools and sometimes they may be updated and improved. If the format of this assay is important to you then please request the current manual or contact our technical support team with a presales inquiry before placing an order. We will confirm the current details of the assay. We cannot guarantee the sample manual posted online is the most current manual, it is intended to serve as an example only. Please refer to the instructions For Use provided with the assay kit for precise details.

Product PubMed Publications

Request a Quote

Please fill out the form below and our representative will get back to you shortly.

MBS000000
Contact Us

Please fill out the form below and our representative will get back to you shortly.

MBS000000