• Call +1.858.633.0165 or Fax +1.858.633.0166 or Contact Us

Coagulation Factor IX (FIX) ELISA Kit for Mouse

For Research Use Only. Not for use in diagnostic procedures. Catalog #: MBS763977

Principle of the Assay||This kit was based on sandwich enzyme-linked immune-sorbent assay technology. anti-Mouse FIX antibody was pre-coated onto 96-well plates. And the biotin conjugated anti-Mouse FIX antibody was used as detection antibodies. The… More details

$405 / 48-Strip-Wells +1 FREE 8GB USB

Product Documentation

PDF
Sample Manual Insert View PDF
PDF
Testing Data View PDF
PDF
Certificate of Analysis (COA) View PDF
PDF
QC Report View PDF
PDF
Material Safety Data Sheet View PDF
PDF
Technical Datasheet View PDF
PDF
Protocol View PDF

Product Overview

Online Datasheet in PDF
Product Name
Coagulation Factor IX (FIX), ELISA Kit
Full Product Name
Mouse Coagulation Factor IX ELISA Kit
Product Gene Name
Product Synonym Names
FIX
Species Reactivity
Mouse
Assay Type
Sandwich ELISA, Double Antibody
Samples
Serum, Plasma, Cell Culture Supernatant, cell or tissue lysate, Other liquid samples
Detection Range
0.156-10ng/ml
Sensitivity
0.094ng/ml
Preparation and Storage
Store entire kit at 2-8C for short-term. For longer-term, please store the microplate & standard at -20C, while the remaining reagents can be stored at 2-8C
Molecular Weight
47,618 Da
OMIM
300746
ISO Certification
Manufactured in an ISO 13485:2003 and EN ISO 13485:2012 Certified Laboratory.

Typical Testing Data of FIX elisa kit

Mouse FIX ELISA Kit – Cat# MBS763977

Typical Standard Curve of FIX elisa kit

Mouse FIX ELISA Kit, Typical Standard Curve – Cat# MBS763977

Other Notes

Small volumes of FIX elisa kit vial(s) may occasionally become entrapped in the seal of the product vial during shipment and storage. If necessary, briefly centrifuge the vial on a tabletop centrifuge to dislodge any liquid in the container`s cap. Certain products may require to ship with dry ice and additional dry ice fee may apply.

Searchable Terms for FIX purchase

MBS763977 is a ready-to-use microwell, strip plate ELISA (enzyme-linked immunosorbent assay) Kit for analyzing the presence of the Coagulation Factor IX (FIX) ELISA Kit target analytes in biological samples. The concentration gradients of the kit standards or positive controls render a theoretical kit detection range in biological research samples containing FIX. The ELISA analytical biochemical technique of the MBS763977 kit is based on FIX antibody-FIX antigen interactions (immunosorbency) and an HRP colorimetric detection system to detect FIX antigen targets in samples. The ELISA Kit is designed to detect native, not recombinant, FIX. Appropriate sample types may include undiluted body fluids and/or tissue homogenates, secretions. Quality control assays assessing reproducibility identified the intra-assay CV (%) and inter-assay CV(%).

Additional Details

NCBI/Uniprot data below describe general gene information for FIX. It may not necessarily be applicable to this product.

NCBI GI #
NCBI GeneID
NCBI Accession #
UniProt Secondary Accession #
UniProt Related Accession #
GenBank Nucleotide #
NCBI Official Full Name
coagulation factor IX isoform 1 preproprotein
NCBI Official Synonym Full Names
coagulation factor IX
NCBI Official Symbol
F9
NCBI Official Synonym Symbols
FIX; P19; PTC; HEMB; THPH8; F9 p22
UniProt Protein Name
Coagulation factor IX
UniProt Synonym Protein Names
Christmas factor; Plasma thromboplastin component; PTC
Protein Family
UniProt Gene Name
F9
UniProt Synonym Gene Names
PTC
UniProt Entry Name
FA9_HUMAN
NCBI Protein Information
coagulation factor IX

NCBI Summary for FIX

This gene encodes vitamin K-dependent coagulation factor IX that circulates in the blood as an inactive zymogen. This factor is converted to an active form by factor XIa, which excises the activation peptide and thus generates a heavy chain and a light chain held together by one or more disulfide bonds. The role of this activated factor IX in the blood coagulation cascade is to activate factor X to its active form through interactions with Ca+2 ions, membrane phospholipids, and factor VIII. Alterations of this gene, including point mutations, insertions and deletions, cause factor IX deficiency, which is a recessive X-linked disorder, also called hemophilia B or Christmas disease. Alternative splicing results in multiple transcript variants encoding different isoforms that may undergo similar proteolytic processing. [provided by RefSeq, Sep 2015]
Show more

UniProt Comments for FIX

F9: Factor IX is a vitamin K-dependent plasma protein that participates in the intrinsic pathway of blood coagulation by converting factor X to its active form in the presence of Ca(2+) ions, phospholipids, and factor VIIIa. Defects in F9 are the cause of recessive X-linked hemophilia B (HEMB); also known as Christmas disease. Mutations in position 43 (Oxford-3, San Dimas) and 46 (Cambridge) prevents cleavage of the propeptide, mutation in position 93 (Alabama) probably fails to bind to cell membranes, mutation in position 191 (Chapel-Hill) or in position 226 (Nagoya OR Hilo) prevent cleavage of the activation peptide. Defects in F9 are the cause of thrombophilia due to factor IX defect (THPH8). A hemostatic disorder characterized by a tendency to thrombosis. Belongs to the peptidase S1 family.

Protein type: Secreted; Secreted, signal peptide; EC 3.4.21.22; Protease

Chromosomal Location of Human Ortholog: Xq27.1-q27.2

Cellular Component: endoplasmic reticulum lumen; extracellular region; extracellular space; Golgi lumen; plasma membrane

Molecular Function: calcium ion binding; endopeptidase activity; serine-type endopeptidase activity

Biological Process: blood coagulation; blood coagulation, extrinsic pathway; blood coagulation, intrinsic pathway; cellular protein metabolic process; ER to Golgi vesicle-mediated transport; peptidyl-glutamic acid carboxylation; post-translational protein modification; proteolysis; signal peptide processing; zymogen activation

Disease: Coumarin Resistance; Hemophilia B; Thrombophilia, X-linked, Due To Factor Ix Defect
Show more

Precautions

All of MyBioSource's Products are for scientific laboratory research purposes and are not for diagnostic, therapeutics, prophylactic or in vivo use. Through your purchase, you expressly represent and warrant to MyBioSource that you will properly test and use any Products purchased from MyBioSource in accordance with industry standards. MyBioSource and its authorized distributors reserve the right to refuse to process any order where we reasonably believe that the intended use will fall outside of our acceptable guidelines.

Disclaimer

While every efforts were made to ensure the accuracy of the information provided in this datasheet, MyBioSource will not be liable for any omissions or errors contained herein. MyBioSource reserves the right to make changes to this datasheet at any time without prior notice.

It is the responsibility of the customer to report product performance issues to MyBioSource within 30 days of receipt of the product. Please visit our Terms & Conditions page for more information.

Product Note

Select online data sheet information is drawn from bioinformatics databases, occasionally resulting in ambiguous or non-relevant product information. It is the responsibility of the customer to review, verify, and evaluate the information to make sure it matches their requirements before purchasing the kit. Our ELISA Kit assays are dynamic research tools and sometimes they may be updated and improved. If the format of this assay is important to you then please request the current manual or contact our technical support team with a presales inquiry before placing an order. We will confirm the current details of the assay. We cannot guarantee the sample manual posted online is the most current manual, it is intended to serve as an example only. Please refer to the instructions For Use provided with the assay kit for precise details.

Product PubMed Publications

Organs/Tissues associated with FIX elisa kit

Request a Quote

Please fill out the form below and our representative will get back to you shortly.

MBS000000
Contact Us

Please fill out the form below and our representative will get back to you shortly.

MBS000000