• Call +1.858.633.0165 or Fax +1.858.633.0166 or Contact Us

Myosin Light Chain 3 (MYL3) ELISA Kit for Rat

For Research Use Only. Not for use in diagnostic procedures. Catalog #: MBS765282

Principle of the Assay: This kit was based on sandwich enzyme-linked immune-sorbent assay technology. Capture antibody was pre-coated onto 96-well plates. And the biotin conjugated antibody was used as detection antibodies. The standards, test samples and… More details

$405 / 48-Strip-Wells +1 FREE 8GB USB

Product Documentation

PDF
Sample Manual Insert View PDF
PDF
Testing Data View PDF
PDF
Certificate of Analysis (COA) View PDF
PDF
QC Report View PDF
PDF
Material Safety Data Sheet View PDF
PDF
Technical Datasheet View PDF
PDF
Protocol View PDF

Product Overview

Online Datasheet in PDF
Product Name
Myosin light chain 3 (Myl3), ELISA Kit
Full Product Name
Rat Myosin light chain 3 ELISA Kit
Product Gene Name
Product Synonym Names
Myl3
Species Reactivity
Rat
Assay Type
Sandwich ELISA, Double Antibody
Samples
Serum, Plasma, Cell Culture Supernatant, cell or tissue lysate, Other liquid samples
Detection Range
0.156-10ng/ml
Sensitivity
0.094ng/ml
Specificity
This assay has high sensitivity and excellent specificity for detection of Myl3. No significant cross-reactivity or interference between Myl3 and analogues was observed.
Preparation and Storage
Store entire kit at 2-8C for short-term. For longer-term, please store the microplate & standard at -20C, while the remaining reagents can be stored at 2-8C
Inter-assay Precision
CV<10%
Intra-assay Precision
CV<8%
Molecular Weight
21,932 Da
OMIM
160790
ISO Certification
Manufactured in an ISO 13485:2003 and EN ISO 13485:2012 Certified Laboratory.

Typical Testing Data/Standard Curve (for reference only) of Myl3 elisa kit

Rat MYL3 ELISA Kit – Cat# MBS765282

Other Notes

Small volumes of Myl3 elisa kit vial(s) may occasionally become entrapped in the seal of the product vial during shipment and storage. If necessary, briefly centrifuge the vial on a tabletop centrifuge to dislodge any liquid in the container`s cap. Certain products may require to ship with dry ice and additional dry ice fee may apply.

Searchable Terms for Myl3 purchase

MBS765282 is a ready-to-use microwell, strip plate ELISA (enzyme-linked immunosorbent assay) Kit for analyzing the presence of the Myosin light chain 3 (Myl3) ELISA Kit target analytes in biological samples. The concentration gradients of the kit standards or positive controls render a theoretical kit detection range in biological research samples containing Myl3. The ELISA analytical biochemical technique of the MBS765282 kit is based on Myl3 antibody-Myl3 antigen interactions (immunosorbency) and an HRP colorimetric detection system to detect Myl3 antigen targets in samples. The ELISA Kit is designed to detect native, not recombinant, Myl3. Appropriate sample types may include undiluted body fluids and/or tissue homogenates, secretions. Quality control assays assessing reproducibility identified the intra-assay CV (%) and inter-assay CV(%).

Additional Details

NCBI/Uniprot data below describe general gene information for Myl3. It may not necessarily be applicable to this product.

NCBI GI #
NCBI GeneID
NCBI Accession #
UniProt Secondary Accession #
UniProt Related Accession #
GenBank Nucleotide #
NCBI Official Full Name
myosin light chain 3
NCBI Official Synonym Full Names
myosin light chain 3
NCBI Official Symbol
MYL3
NCBI Official Synonym Symbols
CMH8; VLC1; VLCl; MLC1V; MLC1SB; MLC-lV/sb
UniProt Protein Name
Myosin light chain 3
UniProt Synonym Protein Names
Cardiac myosin light chain 1
Protein Family
UniProt Gene Name
MYL3
UniProt Synonym Gene Names
MLC-lV/sb
UniProt Entry Name
MYL3_HUMAN
NCBI Protein Information
myosin light chain 3

NCBI Summary for Myl3

MYL3 encodes myosin light chain 3, an alkali light chain also referred to in the literature as both the ventricular isoform and the slow skeletal muscle isoform. Mutations in MYL3 have been identified as a cause of mid-left ventricular chamber type hypertrophic cardiomyopathy. [provided by RefSeq, Jul 2008]
Show more

UniProt Comments for Myl3

MYL3: Regulatory light chain of myosin. Does not bind calcium. Defects in MYL3 are the cause of familial hypertrophic cardiomyopathy type 8 (CMH8). Familial hypertrophic cardiomyopathy is a hereditary heart disorder characterized by ventricular hypertrophy, which is usually asymmetric and often involves the interventricular septum. The symptoms include dyspnea, syncope, collapse, palpitations, and chest pain. They can be readily provoked by exercise. The disorder has inter- and intrafamilial variability ranging from benign to malignant forms with high risk of cardiac failure and sudden cardiac death. CMH8 inheritance can be autosomal dominant or recessive.

Protein type: Motility/polarity/chemotaxis; Motor

Chromosomal Location of Human Ortholog: 3p21.3-p21.2

Cellular Component: A band; cytosol; I band; muscle myosin complex; sarcomere

Molecular Function: actin monomer binding; calcium ion binding; motor activity; myosin II heavy chain binding; structural constituent of muscle

Biological Process: cardiac muscle contraction; metabolic process; muscle filament sliding; positive regulation of ATPase activity; regulation of striated muscle contraction; regulation of the force of heart contraction; skeletal muscle development; ventricular cardiac muscle morphogenesis

Disease: Cardiomyopathy, Familial Hypertrophic, 8
Show more

Precautions

All of MyBioSource's Products are for scientific laboratory research purposes and are not for diagnostic, therapeutics, prophylactic or in vivo use. Through your purchase, you expressly represent and warrant to MyBioSource that you will properly test and use any Products purchased from MyBioSource in accordance with industry standards. MyBioSource and its authorized distributors reserve the right to refuse to process any order where we reasonably believe that the intended use will fall outside of our acceptable guidelines.

Disclaimer

While every efforts were made to ensure the accuracy of the information provided in this datasheet, MyBioSource will not be liable for any omissions or errors contained herein. MyBioSource reserves the right to make changes to this datasheet at any time without prior notice.

It is the responsibility of the customer to report product performance issues to MyBioSource within 30 days of receipt of the product. Please visit our Terms & Conditions page for more information.

Product Note

Select online data sheet information is drawn from bioinformatics databases, occasionally resulting in ambiguous or non-relevant product information. It is the responsibility of the customer to review, verify, and evaluate the information to make sure it matches their requirements before purchasing the kit. Our ELISA Kit assays are dynamic research tools and sometimes they may be updated and improved. If the format of this assay is important to you then please request the current manual or contact our technical support team with a presales inquiry before placing an order. We will confirm the current details of the assay. We cannot guarantee the sample manual posted online is the most current manual, it is intended to serve as an example only. Please refer to the instructions For Use provided with the assay kit for precise details.

Product PubMed Publications

Request a Quote

Please fill out the form below and our representative will get back to you shortly.

MBS000000
Contact Us

Please fill out the form below and our representative will get back to you shortly.

MBS000000