• Call +1.858.633.0165 or Fax +1.858.633.0166 or Contact Us

IL22 ELISA Pair

For Research Use Only. Not for use in diagnostic procedures. Catalog #: MBS8118440

IL22 is a member of a group of cytokines called the IL-1 family of IL-1 superfamily (including IL-19, IL-2, IL-24, and IL-26), a class of potent mediators of cellular inflammatory responses. It shares the use of IL-1R2 in cell signaling with other members of… More details

$395 / 5 Plates +1 FREE 8GB USB
Product Documentation
PDF
Sample Manual Insert View PDF
PDF
Testing Data View PDF
PDF
Certificate of Analysis (COA) View PDF
PDF
QC Report View PDF
PDF
Material Safety Data Sheet View PDF
PDF
Technical Datasheet View PDF
PDF
Protocol View PDF

Product Overview

Online Datasheet in PDF
Product Name
IL22, ELISA Pair
Full Product Name
IL22 Matched ELISA Antibody Pair Set, Human
Product Gene Name
Product Synonym Names
Human IL22 ELISA Pair Set; interleukin 22; IL-22 Matched ELISA Antibody Pair Set, Human; IL-D110 Matched ELISA Antibody Pair Set, Human; IL-TIF Matched ELISA Antibody Pair Set, Human; ILTIF Matched ELISA Antibody Pair Set, Human; TIFa Matched ELISA Antibody Pair Set, Human; TIFIL-23 Matched ELISA Antibody Pair Set, Human; zcyto18 Matched ELISA Antibody Pair Set, Human
Assay Type
Solid Phase Sandwich ELISA
Detection Range
2.03-130pg/mL
Sensitivity
2.03pg/ml
Specificity
Quantitative determination of Human IL22
Preparation and Storage
Capture Antibody: Aliquot and store at -20 degree C to -80 degree C for up to 6 months from date of receipt. Avoid repeated freeze-thaw cycles.
Detection Antibody: Store at 4 degree C and protect it from prolonged exposure to light for up to 6 months from date of receipt. DO NOT FREEZE!
Standard: Store lyophilized standard at -20 degree C to -80 degree C for up to 6 months from date of receipt. Aliquot and store the reconstituted Standard at -80 degree C for up to 1 month. Avoid repeated freeze-thaw cycles.
Materials Provided
1. Capture Antibody 1 mg/mL of mouse anti-Human IL22 monoclonal antibody (in PBS, pH 7.4). Dilute to a working concentration of 2ug/mL in PBS before coating.
2. Detection Antibody 0.2 mg/mL of rabbit anti-Human IL22 monoclonal antibody conjugated to horseradish-peroxidase (HRP) (in PBS, 50 % HRP-Protector, pH 7.4, store at 4 degree C). Dilute to working concentration of 0.5ug/mL in detection antibody dilution buffer before use.
3. Standard Each vial contains 8.8 ng of recombinant Human IL22. Reconstitute with 1 mL detection antibody dilution buffer. After reconstitution, store at -20 degree C to -80 degree C in a manual defrost freezer. A seven-point standard curve using 2-fold serial dilutions in sample dilution buffer, and a high standard of 130 pg/mL is recommended.

Testing Data of IL22 elisa pair

Anti-IL22 ELISA Pair – Cat# MBS8118440

Product References and Citations for IL22 elisa pair

Pestka S. et al., 2004, Annu Rev Immunol. 22: 929-79. Xie MH. et al., 2000, J Biol Chem. 275 (40): 31335-9. Jones BC. et al., 2008, Structure. 16 (9): 1333-44.

Other Notes

Small volumes of IL22 elisa pair vial(s) may occasionally become entrapped in the seal of the product vial during shipment and storage. If necessary, briefly centrifuge the vial on a tabletop centrifuge to dislodge any liquid in the container`s cap. Certain products may require to ship with dry ice and additional dry ice fee may apply.

Searchable Terms for IL22 purchase

MBS8118440 is an ELISA pair targeting IL22. Also known as IL22 Matched ELISA Antibody Pair Set, Human.

Additional Details

NCBI/Uniprot data below describe general gene information for IL22. It may not necessarily be applicable to this product.

Protein Family

Precautions

All of MyBioSource's Products are for scientific laboratory research purposes and are not for diagnostic, therapeutics, prophylactic or in vivo use. Through your purchase, you expressly represent and warrant to MyBioSource that you will properly test and use any Products purchased from MyBioSource in accordance with industry standards. MyBioSource and its authorized distributors reserve the right to refuse to process any order where we reasonably believe that the intended use will fall outside of our acceptable guidelines.

Disclaimer

While every efforts were made to ensure the accuracy of the information provided in this datasheet, MyBioSource will not be liable for any omissions or errors contained herein. MyBioSource reserves the right to make changes to this datasheet at any time without prior notice.

It is the responsibility of the customer to report product performance issues to MyBioSource within 30 days of receipt of the product. Please visit our Terms & Conditions page for more information.

Product Note

Select online data sheet information is drawn from bioinformatics databases, occasionally resulting in ambiguous or non-relevant product information. It is the responsibility of the customer to review, verify, and evaluate the information to make sure it matches their requirements before purchasing the kit. Our ELISA Kit assays are dynamic research tools and sometimes they may be updated and improved. If the format of this assay is important to you then please request the current manual or contact our technical support team with a presales inquiry before placing an order. We will confirm the current details of the assay. We cannot guarantee the sample manual posted online is the most current manual, it is intended to serve as an example only. Please refer to the instructions For Use provided with the assay kit for precise details.
Request a Quote

Please fill out the form below and our representative will get back to you shortly.

MBS000000
Contact Us

Please fill out the form below and our representative will get back to you shortly.

MBS000000