• Call +1.858.633.0165 or Fax +1.858.633.0166 or Contact Us

BIN1 Antibody – Rabbit Polyclonal

For Research Use Only. Not for use in diagnostic procedures. Catalog #: MBS1754933

Background: Chemokine(C-C motif) ligand 24(CCL24) also known as myeloid progenitor inhibitory factor 2(MPIF-2) or eosinophil chemotactic protein 2(eotaxin-2) is a protein that in humans is encoded by the CCL24 gene. By use of PCR analysis of somatic cell… More details

$210 / 0.01 mg +1 FREE 8GB USB
Product Documentation
PDF
Sample Manual Insert View PDF
PDF
Testing Data View PDF
PDF
Certificate of Analysis (COA) View PDF
PDF
QC Report View PDF
PDF
Material Safety Data Sheet View PDF
PDF
Technical Datasheet View PDF
PDF
Protocol View PDF

Product Overview

Online Datasheet in PDF
Product Name
BIN1, Polyclonal Antibody
Full Product Name
Anti-BIN1 Antibody Picoband
Product Gene Name
Clonality
Polyclonal
Isotype
Rabbit IgG
Host
Rabbit
Species Reactivity
Human, Mouse, Rat
Assay Type
Sandwich
Samples
Cell culture supernatants, cell lysates, serum and plasma (heparin, EDTA)
Detection Range
31.2 pg/ml - 2,000 pg/ml
Sensitivity
<2 pg/ml
Form/Format
Lyophilized
Each vial contains 4 mg Trehalose, 0.9 mg NaCl, 0.2 mg Na2HPO4.
Purity/Purification
Immunogen affinity purified.
Concentration
Adding 0.2 ml of distilled water will yield a concentration of 500 ug/ml. (lot specific)
Specificity
Natural and recombinant Human CCL24
Preparation and Storage
Store at -20 degree C for one year from date of receipt. After reconstitution, at 4 degree C for one month. It can also be aliquotted and stored frozen at -20 degree C for six months. Avoid repeated freezing and thawing.
Inter-assay Precision
Inter-Assay Precision (Precision across assays): Three samples of known concentration were tested in separate assays to assess inter-assay precision.
Intra-assay Precision
Intra-Assay Precision (Precision within an assay): Three samples of known concentration were tested on one plate to assess intra-assay precision.
Molecular Weight
593
OMIM
phenotype 601248
3D Structure
ModBase 3D Structure for O00499
ISO Certification
Manufactured in an ISO 13485:2003 and EN ISO 13485:2012 Certified Laboratory.
Applications Tested/Suitable for anti-BIN1 antibody
ELISA (EIA), Flow Cytometry (FC/FACS), Immunofluorescence (IF), Immunohistochemistry (IHC), Immunocytochemistry (ICC), Western Blot (WB)
Application Notes for anti-BIN1 antibody
WB: 0.25-0.5 ug/ml, Human, Mouse, Rat
IHC-P: 2-5 ug/ml, Human
ICC/IF: 5 ug/ml, Human
FC/FACS: 1-3 ug/1x10^6 cells, Human
Direct ELISA: 0.1-0.5 ug/ml, Human
Tested Species: In-house tested species with positive results.
Enhanced Chemiluminescent Kit with anti-Rabbit IgG (#MBS176460) for Western blot, and HRP Conjugated anti-Rabbit IgG Super Vision Assay Kit (#MBS176453) for IHC(P) and ICC.

Western Blot (WB) of anti-BIN1 antibody

Figure 1. Western blot analysis of BIN1 using anti-BIN1 antibody (MBS1754933).

Electrophoresis was performed on a 5-20% SDS-PAGE gel at 70V (Stacking gel)/90V (Resolving gel) for 2-3 hours. The sample well of each lane was loaded with 30 ug of sample under reducing conditions.

Lane 1: human Jurkat whole cell lysates,
Lane 2: human Hela whole cell lysates,
Lane 3: human Skov3 whole cell lysates,
Lane 4: human Caco-2 whole cell lysates,
Lane 5: rat brain tissue lysates,
Lane 6: mouse brain tissue lysates.

After electrophoresis, proteins were transferred to a nitrocellulose membrane at 150 mA for 50-90 minutes. Blocked the membrane with 5% non-fat milk/TBS for 1.5 hour at RT. The membrane was incubated with rabbit anti-BIN1 antigen affinity purified polyclonal antibody (#MBS1754933) at 0.5 ug/mL overnight at 4 degree C, then washed with TBS-0.1%Tween 3 times with 5 minutes each and probed with a goat anti-rabbit IgG-HRP secondary antibody at a dilution of 1:5000 for 1.5 hour at RT. The signal is developed using an Enhanced Chemiluminescent detection (ECL) kit with Tanon 5200 system. A specific band was detected for BIN1 at approximately 65-80 kDa. The expected band size for BIN1 is at 65-80 kDa.
Rabbit Anti-BIN1 Polyclonal Antibody – Cat# MBS1754933

Immunohistochemistry (IHC) of anti-BIN1 antibody

Figure 2. IHC analysis of BIN1 using anti-BIN1 antibody (MBS1754933).

BIN1 was detected in a paraffin-embedded section of human appendiceal adenocarcinoma tissue. Heat mediated antigen retrieval was performed in EDTA buffer (pH 8.0, epitope retrieval solution). The tissue section was blocked with 10% goat serum. The tissue section was then incubated with 2 ug/ml rabbit anti-BIN1 Antibody (MBS1754933) overnight at 4 degree C. Biotinylated goat anti-rabbit IgG was used as secondary antibody and incubated for 30 minutes at 37 degree C. The tissue section was developed using Strepavidin-Biotin-Complex (SABC) with DAB as the chromogen.
Rabbit Anti-BIN1 Polyclonal Antibody, Immunohistochemistry (IHC) – Cat# MBS1754933

Immunohistochemistry (IHC) of anti-BIN1 antibody

Figure 3. IHC analysis of BIN1 using anti-BIN1 antibody (MBS1754933).

BIN1 was detected in a paraffin-embedded section of human gastric adenocarcinoma tissue. Heat mediated antigen retrieval was performed in EDTA buffer (pH 8.0, epitope retrieval solution). The tissue section was blocked with 10% goat serum. The tissue section was then incubated with 2 ug/ml rabbit anti-BIN1 Antibody (MBS1754933) overnight at 4 degree C. Biotinylated goat anti-rabbit IgG was used as secondary antibody and incubated for 30 minutes at 37 degree C. The tissue section was developed using Strepavidin-Biotin-Complex (SABC) with DAB as the chromogen.
Rabbit Anti-BIN1 Polyclonal Antibody, Immunohistochemistry (IHC) – Cat# MBS1754933

Immunohistochemistry (IHC) of anti-BIN1 antibody

Figure 4. IHC analysis of BIN1 using anti-BIN1 antibody (MBS1754933).

BIN1 was detected in a paraffin-embedded section of human lung cancer tissue. Heat mediated antigen retrieval was performed in EDTA buffer (pH 8.0, epitope retrieval solution). The tissue section was blocked with 10% goat serum. The tissue section was then incubated with 2 ug/ml rabbit anti-BIN1 Antibody (MBS1754933) overnight at 4 degree C. Biotinylated goat anti-rabbit IgG was used as secondary antibody and incubated for 30 minutes at 37 degree C. The tissue section was developed using Strepavidin-Biotin-Complex (SABC) with DAB as the chromogen.
Rabbit Anti-BIN1 Polyclonal Antibody, Immunohistochemistry (IHC) – Cat# MBS1754933

Immunofluorescence (IF) of anti-BIN1 antibody

Figure 5. IF analysis of BIN1 using anti-BIN1 antibody (MBS1754933).

BIN1 was detected in an immunocytochemical section of Caco-2 cells. Enzyme antigen retrieval was performed using IHC enzyme antigen retrieval reagent (AR0022) for 15 mins. The cells were blocked with 10% goat serum. And then incubated with 5 ug/mL rabbit anti-BIN1 Antibody (MBS1754933) overnight at 4 degree C. DyLight488 Conjugated Goat Anti-Rabbit IgG (MBS177405) was used as secondary antibody at 1:100 dilution and incubated for 30 minutes at 37 degree C. The section was counterstained with DAPI. Visualize using a fluorescence microscope and filter sets appropriate for the label used.
Rabbit Anti-BIN1 Polyclonal Antibody, Immunofluorescence (IF) – Cat# MBS1754933

Flow Cytometry (FC/FACS) of anti-BIN1 antibody

Figure 6. Flow Cytometry analysis of A431 cells using anti-BIN1 antibody (MBS1754933).

Overlay histogram showing A431 cells stained with MBS1754933 (Blue line). The cells were blocked with 10% normal goat serum. And then incubated with rabbit anti-BIN1 Antibody (MBS1754933, 1 ug/1x10^6 cells) for 30 min at 20 degree C. DyLight488 conjugated goat anti-rabbit IgG (MBS177405, 5-10 ug/1x10^6 cells) was used as secondary antibody for 30 minutes at 20 degree C. Isotype control antibody (Green line) was rabbit IgG (1 ug/1x10^6) used under the same conditions. Unlabelled sample (Red line) was also used as a control.
Rabbit Anti-BIN1 Polyclonal Antibody, Flow Cytometry (FC/FACS) – Cat# MBS1754933

Other Notes

Small volumes of anti-BIN1 antibody vial(s) may occasionally become entrapped in the seal of the product vial during shipment and storage. If necessary, briefly centrifuge the vial on a tabletop centrifuge to dislodge any liquid in the container`s cap. Certain products may require to ship with dry ice and additional dry ice fee may apply.

Searchable Terms for BIN1 purchase

MBS1754933 is an antibody targeting BIN1. Also known as Anti-BIN1 Antibody Picoband. Reactive in Human, Mouse, Rat. Host: Rabbit.

Additional Details

NCBI/Uniprot data below describe general gene information for BIN1. It may not necessarily be applicable to this product.

NCBI GI #
NCBI GeneID
NCBI Accession #
UniProt Primary Accession #
UniProt Secondary Accession #
UniProt Related Accession #
NCBI Official Full Name
Myc box-dependent-interacting protein 1
NCBI Official Synonym Full Names
bridging integrator 1
NCBI Official Symbol
BIN1
NCBI Official Synonym Symbols
AMPH2; AMPHL; SH3P9
UniProt Protein Name
Myc box-dependent-interacting protein 1
UniProt Synonym Protein Names
Amphiphysin II; Amphiphysin-like protein; Box-dependent myc-interacting protein 1; Bridging integrator 1
UniProt Gene Name
BIN1
UniProt Synonym Gene Names
AMPHL
UniProt Entry Name
BIN1_HUMAN
NCBI Protein Information
myc box-dependent-interacting protein 1; amphiphysin II; amphiphysin-like protein; box dependant MYC interacting protein 1; box-dependent myc-interacting protein 1

NCBI Summary for BIN1

This gene encodes several isoforms of a nucleocytoplasmic adaptor protein, one of which was initially identified as a MYC-interacting protein with features of a tumor suppressor. Isoforms that are expressed in the central nervous system may be involved in synaptic vesicle endocytosis and may interact with dynamin, synaptojanin, endophilin, and clathrin. Isoforms that are expressed in muscle and ubiquitously expressed isoforms localize to the cytoplasm and nucleus and activate a caspase-independent apoptotic process. Studies in mouse suggest that this gene plays an important role in cardiac muscle development. Alternate splicing of the gene results in ten transcript variants encoding different isoforms. Aberrant splice variants expressed in tumor cell lines have also been described. [provided by RefSeq, Sep 2011]
Show more

UniProt Comments for BIN1

BIN1: May be involved in regulation of synaptic vesicle endocytosis. May act as a tumor suppressor and inhibits malignant cell transformation. Defects in BIN1 are the cause of centronuclear myopathy type 2 (CNM2). A congenital muscle disorder characterized by progressive muscular weakness and wasting involving mainly limb girdle, trunk, and neck muscles. It may also affect distal muscles. Weakness may be present during childhood or adolescence or may not become evident until the third decade of life. Ptosis is a frequent clinical feature. The most prominent histopathologic features include high frequency of centrally located nuclei in muscle fibers not secondary to regeneration, radial arrangement of sarcoplasmic strands around the central nuclei, and predominance and hypotrophy of type 1 fibers. 11 isoforms of the human protein are produced by alternative splicing.

Protein type: Tumor suppressor; Cytoskeletal; Adaptor/scaffold; Vesicle

Chromosomal Location of Human Ortholog: 2q14

Cellular Component: I band; synaptic vesicle; membrane; axon; T-tubule; cytoplasm; nerve terminal; Z disc; nucleus; actin cytoskeleton

Molecular Function: identical protein binding; protein binding; GTPase binding; protein heterodimerization activity; protein complex binding; tau protein binding

Biological Process: cell proliferation; muscle cell differentiation; viral reproduction; regulation of neuron differentiation; positive regulation of apoptosis; positive regulation of endocytosis; endocytosis; positive regulation of GTPase activity; positive regulation of astrocyte differentiation

Disease: Myopathy, Centronuclear, 2
Show more

Precautions

All of MyBioSource's Products are for scientific laboratory research purposes and are not for diagnostic, therapeutics, prophylactic or in vivo use. Through your purchase, you expressly represent and warrant to MyBioSource that you will properly test and use any Products purchased from MyBioSource in accordance with industry standards. MyBioSource and its authorized distributors reserve the right to refuse to process any order where we reasonably believe that the intended use will fall outside of our acceptable guidelines.

Disclaimer

While every efforts were made to ensure the accuracy of the information provided in this datasheet, MyBioSource will not be liable for any omissions or errors contained herein. MyBioSource reserves the right to make changes to this datasheet at any time without prior notice.

It is the responsibility of the customer to report product performance issues to MyBioSource within 30 days of receipt of the product. Please visit our Terms & Conditions page for more information.

Product Note

Select online data sheet information is drawn from bioinformatics databases, occasionally resulting in ambiguous or non-relevant product information. It is the responsibility of the customer to review, verify, and evaluate the information to make sure it matches their requirements before purchasing the kit. Our ELISA Kit assays are dynamic research tools and sometimes they may be updated and improved. If the format of this assay is important to you then please request the current manual or contact our technical support team with a presales inquiry before placing an order. We will confirm the current details of the assay. We cannot guarantee the sample manual posted online is the most current manual, it is intended to serve as an example only. Please refer to the instructions For Use provided with the assay kit for precise details.

Product PubMed Publications

Pathways associated with anti-BIN1 antibody

Request a Quote

Please fill out the form below and our representative will get back to you shortly.

MBS000000
Contact Us

Please fill out the form below and our representative will get back to you shortly.

MBS000000