• Call +1.858.633.0165 or Fax +1.858.633.0166 or Contact Us

CD38 Molecule (CD38) ELISA Kit for Human

For Research Use Only. Not for use in diagnostic procedures. Catalog #: MBS704723

Principle of the assay: This assay employs the quantitative sandwich enzyme immunoassay technique. Antibody specific for sCD38 has been pre-coated onto a microplate. Standards and samples are pipetted into the wells and any sCD38 present is bound by the… More details

$295 / 24-Strip-Wells (LIMIT 1) +1 FREE 8GB USB

Product Documentation

PDF
Sample Manual Insert View PDF
PDF
Testing Data View PDF
PDF
Certificate of Analysis (COA) View PDF
PDF
QC Report View PDF
PDF
Material Safety Data Sheet View PDF
PDF
Technical Datasheet View PDF
PDF
Protocol View PDF

Product Overview

Online Datasheet in PDF
Product Name
CD38 molecule, ELISA Kit
Full Product Name
Human Soluble Cluster of differentiation 38, sCD38 ELISA Kit
Product Gene Name
Product Synonym Names
Human Soluble Cluster of differentiation 38; sCD38 ELISA Kit; T10; ADP-ribosyl cyclase/cyclic ADP-ribose hydrolase; CD38 antigen; CD38 antigen (p45) ; cyclic ADP-ribose hydrolase; CD38 molecule
Species Reactivity
Human
Assay Type
Sandwich
Samples
Serum, plasma, tissue homogenates and Cell lysates Cell lysates Cell lysates Cell lysates Cell lysates Cell lysates Cell lysates Cell lysates Cell lysates Cell lysates Cell lysates Cell lysates
Detection Range
0.9 ng/ml -60 ng/ml.
Sensitivity
The minimum detectable dose of human sCD38 is typically less than 0.225 ng/ml. The sensitivity of this assay, or Lower Limit of Detection (LLD) was defined as the lowest protein concentration that could be differentiated from zero. It was determined the mean O.D value of 20 replicates of the zero standard added by their three standard deviations.
Specificity
This assay has high sensitivity and excellent specificity for detection of human sCD38. No significant cross-reactivity or interference between human sCD38 and analogues was observed.
Preparation and Storage
Unopened test kits should be stored at 2 to 8 degree C upon receipt. Please refer to pdf manual for further storage instructions.
Inter-assay Precision
Inter-assay Precision (Precision between assays): CV%<10%. Three samples of known concentration were tested in twenty assays to assess.
Intra-assay Precision
Intra-assay Precision (Precision within an assay): CV%<8%. Three samples of known concentration were tested twenty times on one plate to assess.
Molecular Weight
34,328 Da
OMIM
107270
3D Structure
ModBase 3D Structure for P28907
ISO Certification
Manufactured in an ISO 9001:2015 Certified Laboratory.

Typical Testing Data/Standard Curve (for reference only) of CD38 elisa kit

Human CD38 ELISA Kit – Cat# MBS704723

Other Notes

Small volumes of CD38 elisa kit vial(s) may occasionally become entrapped in the seal of the product vial during shipment and storage. If necessary, briefly centrifuge the vial on a tabletop centrifuge to dislodge any liquid in the container`s cap. Certain products may require to ship with dry ice and additional dry ice fee may apply.

Searchable Terms for CD38 purchase

MBS704723 is a ready-to-use microwell, strip plate ELISA (enzyme-linked immunosorbent assay) Kit for analyzing the presence of the CD38 molecule, ELISA Kit target analytes in biological samples. The concentration gradients of the kit standards or positive controls render a theoretical kit detection range in biological research samples containing CD38. The ELISA analytical biochemical technique of the MBS704723 kit is based on CD38 antibody-CD38 antigen interactions (immunosorbency) and an HRP colorimetric detection system to detect CD38 antigen targets in samples. The ELISA Kit is designed to detect native, not recombinant, CD38. Appropriate sample types may include undiluted body fluids and/or tissue homogenates, secretions. Quality control assays assessing reproducibility identified the intra-assay CV (%) and inter-assay CV(%).

Additional Details

NCBI/Uniprot data below describe general gene information for CD38. It may not necessarily be applicable to this product.

NCBI GI #
NCBI GeneID
NCBI Accession #
UniProt Primary Accession #
UniProt Secondary Accession #
UniProt Related Accession #
GenBank Nucleotide #
NCBI Official Full Name
ADP-ribosyl cyclase/cyclic ADP-ribose hydrolase 1
NCBI Official Synonym Full Names
CD38 molecule
NCBI Official Symbol
CD38
NCBI Official Synonym Symbols
T10; ADPRC 1
UniProt Protein Name
ADP-ribosyl cyclase/cyclic ADP-ribose hydrolase 1
UniProt Synonym Protein Names
2'-phospho-ADP-ribosyl cyclase; 2'-phospho-ADP-ribosyl cyclase/2'-phospho-cyclic-ADP-ribose transferase (EC:2.4.99.20); 2'-phospho-cyclic-ADP-ribose transferase; ADP-ribosyl cyclase 1; ADPRC 1; Cyclic ADP-ribose hydrolase 1; cADPr hydrolase 1; T10; CD_antigen: CD38
UniProt Gene Name
CD38
UniProt Synonym Gene Names
ADPRC 1; cADPr hydrolase 1
UniProt Entry Name
CD38_HUMAN
NCBI Protein Information
ADP-ribosyl cyclase/cyclic ADP-ribose hydrolase 1; cADPr hydrolase 1; CD38 antigen (p45); NAD(+) nucleosidase; ADP-ribosyl cyclase 1; 2'-phospho-ADP-ribosyl cyclase; 2'-phospho-cyclic-ADP-ribose transferase; 2'-phospho-ADP-ribosyl cyclase/2'-phospho-cyclic-ADP-ribose transferase

NCBI Summary for CD38

CD38 is a novel multifunctional ectoenzyme widely expressed in cells and tissues especially in leukocytes. CD38 also functions in cell adhesion,signal transduction and calcium signaling. [provided by RefSeq, Jul 2008]

UniProt Comments for CD38

Function: Synthesizes the second messagers cyclic ADP-ribose and nicotinate-adenine dinucleotide phosphate, the former a second messenger for glucose-induced insulin secretion. Also has cADPr hydrolase activity. Also moonlights as a receptor in cells of the immune system.

Catalytic activity: NAD+ + H2O = ADP-D-ribose + nicotinamide.1 PublicationManual assertion based on experiment in:Ref.8

Enzyme regulation: ATP inhibits the hydrolyzing activity.
Show more

Precautions

All of MyBioSource's Products are for scientific laboratory research purposes and are not for diagnostic, therapeutics, prophylactic or in vivo use. Through your purchase, you expressly represent and warrant to MyBioSource that you will properly test and use any Products purchased from MyBioSource in accordance with industry standards. MyBioSource and its authorized distributors reserve the right to refuse to process any order where we reasonably believe that the intended use will fall outside of our acceptable guidelines.

Disclaimer

While every efforts were made to ensure the accuracy of the information provided in this datasheet, MyBioSource will not be liable for any omissions or errors contained herein. MyBioSource reserves the right to make changes to this datasheet at any time without prior notice.

It is the responsibility of the customer to report product performance issues to MyBioSource within 30 days of receipt of the product. Please visit our Terms & Conditions page for more information.

Product Note

Select online data sheet information is drawn from bioinformatics databases, occasionally resulting in ambiguous or non-relevant product information. It is the responsibility of the customer to review, verify, and evaluate the information to make sure it matches their requirements before purchasing the kit. Our ELISA Kit assays are dynamic research tools and sometimes they may be updated and improved. If the format of this assay is important to you then please request the current manual or contact our technical support team with a presales inquiry before placing an order. We will confirm the current details of the assay. We cannot guarantee the sample manual posted online is the most current manual, it is intended to serve as an example only. Please refer to the instructions For Use provided with the assay kit for precise details.

Product PubMed Publications

Request a Quote

Please fill out the form below and our representative will get back to you shortly.

MBS000000